Incident Library

IL-0289 updown.io · 2019-04-03database

A failing SSD made updown.io's primary MongoDB about 200 times slower, no failover happened and the site went down

updown.io runs MongoDB with a primary server, whose data sits on 3 SSDs in RAID5, and a less powerful secondary. When one SSD started to fail at 2:30 am CEST on 3 April 2019, the primary slowed to about 200 times its normal query time but kept answering the heartbeat, so MongoDB never failed over. The founder was asleep and noticed the problem at 8:45 am, checked that the secondary was ready and forced the primary to step down; the website and daemons recovered at 8:56 am, more slowly than usual on the weaker secondary. The founder then found the failing SSD, took it out of the array, which restored the old primary's performance, and asked the hosting provider to replace it. On the following two nights the weaker secondary, now primary, failed again because a daily clamscan antivirus run took memory from MongoDB: on 4 April the kernel's OOM killer killed MongoDB, and on 5 April the server slowed and the DNS automatic failover switched to the disabled primary. On 6 April at 12:48 pm the secondary was replaced with a more powerful server and response times returned to normal. When the provider replaced the SSD, a second SSD had died in the same way, apparently both far past their rated endurance; it was replaced on 16 April and the original server became primary again on 22 April. The script written afterwards to force a step-down when MongoDB is up but unresponsive cut the downtime to under 10 minutes when the third SSD died on 6 November 2019, and in 2020 MongoDB's Storage Node Watchdog, then opened to the community edition, replaced the script.

Severity
–
Scope
The updown.io website and monitoring daemons were almost fully down from 2:30 am to 8:56 am CEST, then ran with lower performance on the less powerful secondary
Users affected
–
Region
–
Time to detect
6h 15m
Time to resolve
6h 26m

Symptoms

At 2:30 am CEST on 3 April 2019, the primary MongoDB server of updown.io started answering queries about 200 times slower than usual, and the website and the monitoring daemons went almost completely down.

MongoDB's automatic failover did not react, because the replica set heartbeat check still answered quickly; a secondary server was ready to take over but was never elected primary (MongoDB ticket SERVER-29980). On the primary, atop showed the IO usage ("busy") and average latency ("avgio") of its three disks, and the founder found an IO performance problem.

Symptom High latencyService outageFailover failure

Root cause

Root cause Hardware failure

Contributing factor –
Trigger
One of the three SSDs in the primary MongoDB server's RAID5 array began to fail, slowing the server's IO without taking the server down.

Detection

The founder, who was asleep when the slowdown began, noticed the problem at 8:45 am CEST and found the IO performance issue by inspecting the primary server.

Remediation

Action items

Lessons

–

Sources