Intercom's US region was fully down for 71 minutes when its Vitess VTGates dropped all routes to the database shards

Intercom uses PlanetScale, built on Vitess, as its core database layer. At 18:56 UTC on January 9, 2026, a configuration in the database management pipeline read a 'branch unfreeze' action as a signal to go ahead with a pending upgrade to Vitess v22 that was scheduled for the following week, and the upgrade began rolling out at 19:00 UTC. At 19:30 UTC a MoveTables workflow, part of a standard administrative task to move tables for testing, failed because of transient networking issues in the provider's Kubernetes cluster.

When a MoveTables command fails, Vitess attempts to revert its state. For unsharded keyspaces it keeps the previous VSchema in memory for this rollback, and for sharded keyspaces it saves nothing, because the operation is not expected to change the VSchema there. A regression in v22, introduced in Vitess Pull Request #17401, made the check for whether to reapply the old VSchema come out true for Intercom's sharded keyspace, so Vitess applied a previous VSchema it had never saved, which was empty. At 19:39 UTC the PlanetScale control plane read the empty VSchema and passed it to the VTGates, which dropped all routes.

Engineers and an incident commander acknowledged the incident at 19:41 UTC and engaged PlanetScale at 19:48 UTC. At 20:50 UTC PlanetScale engineers reapplied a VSchema snapshot taken one hour before the incident and removed what the failed workflow had left behind; the control plane pushed the valid routing rules to the VTGates, which rebuilt their routing tables, and service recovered. From 21:00 UTC Vitess was rolled back to v21 over the following hours. Intercom found no evidence of data loss or corruption. The networking packet drops in the provider's Kubernetes cluster may have contributed by causing the workflow failure that set off the bug.

Severity
–
Scope
All Intercom services in the US region were unavailable for 71 minutes
Users affected
Intercom customers hosted in the US region
Region
US
Time to detect
1m
Time to resolve
1h 11m

Symptoms

From 19:39 to 20:50 UTC on January 9, 2026, all Intercom services in the US region were unavailable to customers hosted there. Queries from the Intercom application could not reach the database shards, and Inbox Heartbeat Anomaly alarms fired in the US region at 19:40 UTC.

Intercom's core database layer is PlanetScale, built on Vitess, and its proxy layer, the VTGates, routes each query to the right shard using the VSchema. An empty VSchema had been applied to the production keyspace, the PlanetScale control plane passed it to the VTGates, and the VTGates dropped all their routes, so the application lost all connectivity to its data. Queries could not be routed or run, but stored data was not changed.

Symptom Service outage

Root cause

Trigger
At 18:56 UTC a configuration in the database management pipeline treated a 'branch unfreeze' action as a signal to start a Vitess v22 upgrade planned for the following week. At 19:30 UTC a MoveTables workflow failed during transient networking issues in the provider's Kubernetes cluster, and the v22 rollback logic applied an empty VSchema.

Detection

Inbox Heartbeat Anomaly alarms fired in the US region at 19:40 UTC and declared an incident; engineers and an incident commander acknowledged it at 19:41 UTC.