Incident Library

IL-0563 Linode · 2025-03-17networking

Linode servers lost connectivity in all data centers as route servers built incomplete BGP route tables

Akamai Compute was rolling out a release of its internal backend API component. While the rollout was in progress, the API's responses were inconsistent between endpoints, and the route servers that read route data from it built incomplete route tables for BGP. With incomplete routes, connectivity broke in all data centers from about 16:38 UTC, and Amsterdam (NL-AMS) came close to a full outage.

When the release concluded at 17:10, the data between endpoints became consistent again and most data centers recovered by themselves. To clear the remaining impact, Linode restarted the route servers in all data centers from about 18:30, in phases with the most affected regions first, and finished at about 21:34. Backend API releases were put on hold until there is a better way to make sure the route data given to route servers is contiguous.

Severity
–
Scope
network connectivity to servers in all data centers; in Amsterdam, deploying and booting Linodes and other host-level jobs failed and the data center was nearly fully down; Object Storage and LKE access could fail
Users affected
–
Region
all regions, worst in Amsterdam (NL-AMS)
Time to detect
–
Time to resolve
4h 56m

Symptoms

At about 16:38 UTC on 17 March 2025, internal alerts fired across multiple Linode data centers because various servers had been unreachable for an extended period. At the same time customers began reporting problems with several products.

Networking problems showed up in all data centers, and Amsterdam (NL-AMS) was hit hardest. There customers could not deploy new Linodes, boot existing Linodes or run other host-level jobs, and the data center had a near-total outage. Access to services such as Object Storage and Linode Kubernetes Engine (LKE) could also fail.

When the release behind the problem finished at 17:10 UTC, most data centers recovered on their own. The remaining impact, worst in Amsterdam, lasted until route servers were restarted region by region between about 18:30 and 21:34 UTC.

Symptom Network unreachableService outage

Root cause

Trigger
A release of Akamai Compute's internal backend API component was rolling out, and during the rollout the API gave inconsistent responses to the route servers.

Detection

Internal alerts fired across multiple data centers showing servers unreachable for an extended period, and customers reported problems with multiple products at the same time.

Remediation

Action items

Lessons

–