  1. Symptoms

    On a Sunday, a team using one of Skyscanner's Kubernetes clusters manually paged the out-of-hours Kubernetes support because their service showed elevated latency, worst at the p90 and maximum levels.

    Trigger

    Upgrading the HAProxy ingress controller to v0.6 and going back from Service virtual IPs to individual pod IPs as backends, on the understanding that the sort-backends flag introduced in v0.5, false by default, meant backends were randomly shuffled.

    Root cause
    Component
    Contributing factor
    Detection

    A cluster user manually paged the out-of-hours Kubernetes support about elevated latency; Prometheus queries then showed the uneven request distribution across pods.

    Remediation
    • switched the affected service from pod IPs back to the Service virtual IP through a config change in the internal deployment tool Slingshot
    • patched the controller to keep each backend's servers in an insertion-ordered slice and changed the template to iterate over that slice
    • tested the patch in sandbox clusters and rolled it out to the production clusters
    Action items
    • Run the internal controller patch in production and return to pod IPs as the default backends
    • Raise the problem upstream with a GitHub issue and pull request
    • Test changes to cluster components against the specific behaviour and conditions that matter
    Lessons

    The team already knew that sorted backends cause hot-podding and still did not test the new flag well enough to see that it did not work; changes to cluster components need tests aimed at the exact behaviour that matters, under conditions like production. A keyword can behave differently in different parts of a language: range over a map is unordered in Go code but sorted in text/template. A small cluster component can do outsized harm to every user of the cluster and, in the end, to customers.

  2. Symptoms

    On 8 February 2019 the Kubernetes project's Prow instance at prow.k8s.io became very slow: its controllers took about five minutes to respond to the hook, bot commands such as the cat command stopped working, and the prow.k8s.io site was hard to reach. GitHub status was normal, and the Prow service nodes were found running above 100% of CPU and memory.

    Trigger

    At 13:20 PST an auto-generated bump PR for Prow was merged and deployed, and Prow started scheduling workloads onto the service cluster.

    Root cause
    Component
    Contributing factor
    Detection

    While working on a PR, a maintainer noticed the bot's cat command failing, found GitHub status normal, learned on Slack that the Prow nodes were above 100% CPU and memory, and then found 600 pending pods in the test-pods namespace.

    Remediation
    • Rolled Prow back to v20190206-b01b288 and cleaned up the pods and ProwJobs in the service cluster
    • Applied the revert by hand with kubectl apply after the deployment permission was missing
    • Sent a fix, PR 11209, so the client no longer overwrites a provided literal default client
    • Rolled Prow back to v20190125-2aca69d, from before the bug was introduced
    • Cleaned up the wrongly scheduled pods and ProwJobs again and confirmed Prow was healthy
    Action items
    • Find out why the bug did not show deterministically
    • Be more careful with sweeping Prow changes, with more end-to-end tests or a real staging Prow
    Lessons

    The behaviour was not deterministic, and the change was deployed on a Friday afternoon. Prow instances are set up differently, for example in how build clusters are defined, so another project's Prow running a version fine does not show it is safe for the Kubernetes Prow, which needs a staging environment that looks like it.

  3. Symptoms

    The NU.nl development team got reports that several services on one of its Kubernetes clusters behaved erratically: occasional error pages, slow responses and timeouts. The affected services were mostly internal tools and dashboards.

    Trigger

    A new ElastAlert rule, deployed shortly before from the command line, that fired if the Cloudfront-* Elasticsearch indexes stopped receiving documents; those indexes take a few million requests per hour, and the rule made ElastAlert's memory grow without bound.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported error pages, slow responses and timeouts from several services; no alert fired.

    Remediation
    • terminated the NotReady nodes one by one so the auto-scaling group replaced them (the new nodes also went NotReady, but Prometheus and Grafana landed on a stable node)
    • found the ElastAlert pods' memory growth on the Grafana pod memory dashboard
    • fixed the ElastAlert problem that caused the memory growth
    Action items
    • Define alerts on resource usage such as CPU, memory and disk space
    • Keep researching an alerting strategy that combines Elasticsearch, Prometheus Alertmanager and New Relic
    • Consider exporting metrics out of the cluster and running Grafana outside it, on EC2 or a separate Kubernetes cluster
    • Either visualise the important metrics in the ELK stack or make Prometheus and Grafana more available, and improve the metrics strategy
    • Set resource limits for ElastAlert through the Helm values
    • Configure namespaces with default memory requests and limits
    • Isolate customer-facing workloads from build, logging and monitoring workloads (a dedicated node group, or later a separate tools cluster)
    • Deploy everything through automation such as Jenkins pipelines, and consider a GitOps approach
    • Deploy through a pipeline that includes a smoke test step
    • Make Kubernetes and cloud infrastructure work part of the team's sprints, picked up by all team members while pairing with more experienced members, and hold workshops that go deep into specific topics
    Lessons

    Fixing the root cause covers only a small part of what an incident can teach; the chain of smaller failures around it is where most of the learning is. A pod without a memory limit can take whole nodes down, so limits need defaults at the namespace level. Monitoring that runs inside the cluster it watches goes blind with it. Changes installed by hand from the command line leave the rest of the team without a record of what changed.

  4. Symptoms

    After Civis released its new script infrastructure on Kubernetes internally in September 2018, developers reported that kubectl commands were slow, and users intermittently could not start notebooks and services.

    Trigger

    Migrating clients' Python, R and container scripts from the in-house Bocce system to Kubernetes (the project called Croquet) pushed the cluster to about 290 EC2 instances under a large script load.

    Root cause
    Component
    Contributing factor
    Detection

    Developer reports of slow kubectl commands and user reports of notebooks and services failing to start, then high CPU on the master nodes.

    Remediation
    • moved internal users back to the old Bocce infrastructure
    • resized the three master nodes from m4.large to m4.4xlarge
    • changed the Datadog setup so per-node agents no longer polled the API server for service metadata
    • raised max-requests-inflight for non-mutating requests from 400 to 1200
    • grew the etcd EBS volumes from 20 to 100 GB (100 to 300 IOPS)
    • switched client scripts from the ClusterFirst DNS policy to Default
    Action items
    • Upgrade etcd from 2.2.1 to 3.x once Kops supports a safe migration
    • Solve the in-cluster DNS timeouts so client scripts can talk to other workloads in the cluster
    Lessons

    Kubernetes can reach thousands of nodes only after tuning, and third-party DaemonSets are a common cause of control plane load: an agent on every node that polls or watches the API server multiplies with the cluster size. Datadog, kube2iam and the fluentd metadata filter all showed this. A small configuration change often fixes it, but finding it took load testing and the API server access logs.

  5. Symptoms

    An upgrade of the network subsystem under Target's datacenter OpenStack, meant to cause only a brief disruption, ran into problems and left network connectivity disrupted for several hours. Kafka, which runs on that OpenStack, became intermittently available.

    Trigger

    A network subsystem upgrade in the datacenter OpenStack infrastructure disrupted connectivity for several hours and made Kafka intermittently available.

    Root cause
    Component
    Contributing factor
    Remediation
    • enabled gossip encryption on Consul so messages from the poisoned mesh were rejected
    • stabilized the deployment engine and redeployed the development environment with encryption, terminating instances without it
    • upgraded Consul in place to 1.2.3 and then to 1.3.0
    Action items
    • Reduce how much of an outage a single Docker daemon can cause, together with running smaller and more numerous clusters
    Lessons

    Smaller and more numerous clusters limited the damage: the smaller development clusters and production were not hit the same way as the one large cluster, and dev and prod on one cluster would have been far worse. A Docker daemon shared by many workloads is a brittle failure point. Per-workload logging and metrics sidecars were judged the right design; a shared cluster-level agent would almost certainly have made the problem worse and harder to fix.

Check your cluster for this

These 45 cases involve Linux kernel and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Capacity exhaustion17 cases

  1. IL-0471 GitHub Actions runs failed or sat queued for 9 hours after a routine deployment's pod replacement saturated capacity
    GitHub2026
  2. IL-0470 Buildkite notifications were delayed after Prometheus storage filled and EKS notification workers could not autoscale
  3. IL-0548 Buildkite's EKS Prometheus server was killed for memory again and again, so services stopped scaling and jobs lagged
  4. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  5. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  6. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  7. IL-0413 LLM inference engines timed out or ran out of resources under load in about 60% of 156 severe incidents at Microsoft
  8. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  9. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  10. IL-0232 Calico pods in the codfw WikiKube cluster hit their resource limits and crash-looped, taking nodes out one by one
  11. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  12. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  13. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  14. IL-0140 The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worse
  15. IL-0206 Consul agents in GitLab.com's GKE pods were repeatedly OOM-killed, so the Rails pods lost database replica discovery and sent every query to the primary
    GitLab2022
  16. IL-0033 Uneven load across kube-dns pods and a DNS packets-per-second limit pushed service latency to 20 seconds
    Airbnb2019
  17. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API

Configuration change8 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0118 A global change to Kubernetes namespace labels made the networking layer recompute metadata and overwhelmed the control planes of three of OpenAI's largest GPU clusters
    OpenAI2024
  3. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
  4. IL-0461 Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNS
  5. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  6. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  7. IL-0189 A JVM service moved from EC2 to Kubernetes answered up to ten times slower because KIAM's 15-minute credentials made the AWS Java SDK fetch new credentials on every request
  8. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Software defect10 cases

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  2. IL-0247 One in a million search requests took 100 times longer on Pinterest's Manas leaf nodes after moving to Kubernetes
  3. IL-0081 API requests timed out during deployment rollouts because the ingress-nginx enable-serial-reloads option held back endpoint updates while a long NGINX reload was running
    Cresta2025
  4. IL-0495 HubSpot's internal load balancers on Kubernetes were falsely marked unhealthy and the rest collapsed under the traffic
  5. IL-0141 gke-metadata-server versions 0.4.272 to 0.4.280 flooded Cloud Logging with "Unable to sync sandbox" debug logs on GKE clusters with Workload Identity, using up logging quota and adding billable usage
  6. IL-0151 A latent defect in the AWS Lambda Frontend, set off when one us-east-1 cell scaled past a size never reached before, raised errors for Lambda and for services that depend on it, including new EKS cluster provisioning
  7. IL-0462 Some MySQL pods on Shopify's GKE clusters took up to 30 minutes to start, slowing instance replacement
  8. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  9. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  10. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order

Faulty deployment2 cases

  1. IL-0324 Three MediaWiki deployments lost Memcached after a PHP 8.1 rollout and overloaded the External Storage database cluster
  2. IL-0466 Prow scheduled test job pods onto its service cluster, leaving hundreds Pending and starving Prow's own services

Cloud provider outage3 cases

  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU
  2. IL-0364 A quarter of Cloud Platform ingress traffic was slow because an AWS NLB stopped health-checking targets in one zone
  3. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021

DNS or network fault4 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node
  3. IL-0057 Higher p99 latency after moving a reverse proxy to EKS, from outgoing connections delayed by a SNAT conntrack race
    Prezi2019
  4. IL-0047 Pod-to-pod requests delayed by 5, 10 or 15 seconds because of DNS lookups lost to a conntrack race

Dependency failure1 case

Organisation
  1. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019