  1. Symptoms

    Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.

    Trigger

    An abnormally large number of queries arrived from many separate connections within a few minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.

    Remediation
    • Scaled the ingest fleet up manually and aggressively
    • Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
    • Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
    Action items
    • Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
    • Decide on the projects that will address these failure paths
    Lessons

    Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.

  2. Symptoms

    Shortly after incident.io moved its infrastructure fully into Google Cloud, the application saw a larger-than-normal number of Postgres connection timeouts, and new database connections per second were in the hundreds, spiking up and down. At the same time, the memcached instance used for transient data and faster API responses had sporadic connection timeouts.

    Trigger

    After the move to Google Cloud, the application opened hundreds of new Postgres connections per second, and an accidental database join made it send thousands of duplicate calls to an external third party in parallel.

    Root cause
    Component
    Contributing factor
    Detection

    An incident was declared when the number of Postgres connection timeouts rose above normal. The remaining cache timeouts were traced through the logs of the Kubernetes node that served an affected request, the request's trace and the node's metrics.

    Remediation
    • Doubled the maximum Postgres connection lifespan from 15m to 30m
    • Made the Postgres connection pools static so they always keep N connections open
    • Raised the memcache client's MaxIdleConns from 2 to 20
    • Moved temporarily from Google's hosted memcached to a memcached inside the Kubernetes cluster
    • Shipped the fix for the accidental database join that made thousands of duplicate external calls
    Action items
    • Set more sensible concurrency limits for outbound network calls
    Lessons

    Network timeouts are not always local to one request or pod: when they appear, the whole activity of the node, including other pods on it, needs to be checked. Staying within a provider's rate limits does not keep outbound calls from affecting a node, so outbound network calls need more sensible concurrency limits.

Check your cluster for this

These 7 cases involve In-memory cache and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause3

Configuration change1 case

Organisation
  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks

Capacity exhaustion5 cases

  1. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  2. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  3. IL-0067 Redis filled its persistent volume, corrupted its append-only file and crash-looped on every restart
  4. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  5. IL-0386 After a move to Google Cloud, Postgres connection timeouts and memcached i/o timeouts spiked on GKE nodes

Faulty deployment1 case

  1. IL-0324 Three MediaWiki deployments lost Memcached after a PHP 8.1 rollout and overloaded the External Storage database cluster