Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases11 cases

6 to 10 of 11

  1. Symptoms

    Services on the production Amazon EKS cluster behind the idus marketplace threw intermittent errors whose cause was hard to pin down. Calls to external services such as RDS and Redis failed now and then, and whenever DNS traffic spiked, domain lookups answered slowly or failed outright.

    Trigger

    All CoreDNS pods were scheduled onto the same node, and that node's memory usage spiked until it ran out of memory.

    Root cause
    Component
    Contributing factor
    Detection

    The write-up does not say how the full outage was noticed. The earlier DNS trouble showed up as intermittent service errors, and investigating failed calls to RDS and Redis led to DNS resolution failures.

    Remediation
    • deployed NodeLocal DNSCache as a DaemonSet in front of CoreDNS
    • added a PodDisruptionBudget (maxUnavailable 1) and topologySpreadConstraints across zones for CoreDNS
    • lowered ndots from 5 to 2 with dnsConfig in the Deployments
    Lessons

    The CoreDNS setup that EKS creates by default (two pods) can be enough for a small or development cluster but becomes a bottleneck in a large production cluster, and DNS is a single point of failure that needs high availability and room to scale. Tuning the CoreDNS cache and buffer size only relieved the symptoms; the real load came from the extra queries that ndots:5 generates for external names. A CoreDNS pod without a memory limit can share a node's fate with everything else on it.

  2. Symptoms

    At 14:05 on 25 July 2023, a high-priority PagerDuty alert from Pingdom reported that the "Prometheus - live healthcheck" was DOWN. Prometheus on the live cluster was unavailable, and the Cloud Platform lost its monitoring for a while.

    Trigger

    The growing number of namespaces and Prometheus rules raised Prometheus' memory needs beyond what its node instance size could hold.

    Root cause
    Component
    Contributing factor
    Detection

    A Pingdom health check on Prometheus failed and raised a high-priority PagerDuty alert.

    Remediation
    • drained the monitoring node, moving Prometheus to another monitoring node
    • changed the node instance size to r6i.4xlarge
    • raised the Prometheus memory limit to 100Gi
    • set the Prometheus container limits to 12 CPU cores and 110Gi of memory
    Action items
    • Add an alert on node memory usage and on a pod using up most of a node's memory (issue #4538)
  3. Symptoms

    The hub pod of the prod JupyterHub on the leap cluster (leap.2i2c.org) restarted unexpectedly during a large node scale-up, and a user opened a support ticket. The ingress-nginx and proxy pods kept running.

    Trigger

    A user's dask-gateway workload added about 100 dask-worker nodes within a minute, and Prometheus started scraping the metrics exporters on about 200 nodes.

    Root cause
    Component
    Contributing factor
    Detection

    A user support ticket (2i2c Freshdesk ticket 414) about the leap hub; the engineer then looked at Grafana and the cluster's nodes and events.

    Action items
    • Configure CPU and memory requests for the hub and proxy pods (#2127; at least 100m CPU was proposed)
    • Make the Grafana OOMKiller dashboard work (#2213)
    • Move LEAP cloud infrastructure to shared nodes (#2209)
    • Update resource requests and limits, mainly for ingress-nginx and Prometheus (#2324)
    • Decide whether Prometheus should scrape dask worker pods (#2366)
    Lessons

    Prometheus load grows with the number of nodes, so a burst of autoscaled nodes can push a nearly full core node over the edge and evict the pods that matter most. Core pods that request 10m of CPU get a tenth of the CPU share of busy neighbours that request 100m. Kubernetes events expire after an hour, so evidence of OOM kills needs a dashboard that keeps it.

  4. Symptoms

    At 08:52 PM IST a report came in from WER that many students could not access the JupyterHub and that it was frozen; pages were stuck and nothing was usable. A rise in activity was visible by 09:02 PM, but the usual fixes, such as opening an incognito window and restarting servers, did not help.

    Trigger

    WER students' pods used a good chunk of their memory limit (tests had shown they almost always use just under 1G of their 2G limit, against a 512M guarantee) on nodes shared with the hub's core pods.

    Root cause
    Component
    Contributing factor
    Detection

    WER reported stuck pages and students unable to reach the hub in a GitHub issue (2i2c-org/docs#27).

    Remediation
    • removed memory overcommit for the WER students
    • raised resource guarantees for all core pods, which restarted them and moved some to a new node
    Action items
    • Put user pods in a separate pool so they do not create pressure on the core pods (infrastructure#89)
    • Set limits on the support infrastructure (Prometheus, Grafana, ingress) as well (infrastructure#90)
    • Document and think about overcommit ratios for memory usage (infrastructure#91)
    • Set up better Grafana dashboards to monitor resource usage (infrastructure#92)
    • Document how people can get kubectl access to the cluster so others can look into issues too (infrastructure#87)
    Lessons

    Core pods without resource guarantees get whatever is left on a node, so when user pods on the same nodes fill the CPU and memory, the hub that serves everyone freezes. The memory overcommit ratio has to come from measured use: WER students used just under 1G against a 512M guarantee, which a 4x overcommit could not hold.

  5. Symptoms

    Shortly after a round of changes, loveholidays saw connectivity problems and raised error rates on its aggregation service. The service is a proxy between two other services of more than 100 instances each, handles over 10,000 requests per second continuously and can spike to four times that.

    Trigger

    Three changes together: a change in service architecture, halving the RAM of the nodes that run the aggregation service, and sharding a downstream service, which doubled the number of connections to track.

    Root cause
    Component
    Contributing factor
    Detection

    Rising error rates and climbing connection reset errors in HAProxy, then node_exporter conntrack metrics compared with their limit.

    Remediation
    • moved the aggregation service to nodes with more RAM
    • limited the number of aggregation service pods per node
    Action items
    • Alert when conntrack table use goes above 75%, with (node_nf_conntrack_entries / on (pod) node_nf_conntrack_entries_limit / on (pod) group_right kube_pod_info) > 0.75
    Lessons

    The conntrack limit is tied to node memory, so resizing a node pool silently resizes the connection table, and on GKE the ratio did not match the commonly cited formula. A high-traffic proxy on small nodes can exhaust it, and the symptoms are connection resets and timeouts, so conntrack use needs its own metric and alert.

Check your cluster for this

These 11 cases involve Node pool and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing