  1. Symptoms

    At 12:32 Prometheus on the Cloud Platform was not available after a planned change, and the Prometheus pod had restarted several times. The platform lost its monitoring and had missing metrics for the period.

    Trigger

    A planned change restarted Prometheus at a time when the WAL count was high.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw that the Prometheus pod had restarted several times after the planned change.

    Remediation
    • raised the Prometheus startupProbe threshold to 30 minutes
    Action items
    • Perform planned Prometheus restarts when the WAL count is lower
    • Set the default CPU and memory requests to meet maximum usage
    • Create a test setup that recreates the live WAL count
    • Explore the memory-snapshot-on-shutdown and auto-gomaxprocs feature flags
    • Explore storing WAL files remotely in a different location
    • Look into a blue-green Prometheus to test changes on a live-like setup before applying them to live
    • Spike into Amazon Managed Prometheus
  2. Symptoms

    One evening, right after an ordinary restart of kube-apiserver in a customer's production cluster, etcd memory consumption rose almost threefold. The sudden growth led to a cascading restart of all the master nodes.

    Trigger

    An ordinary restart of kube-apiserver, after which every pod of the log collector DaemonSet sent its list requests at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    Memory graphs showed etcd memory on the master nodes almost tripling after a kube-apiserver restart; the audit logs then pointed to one DaemonSet's list requests.

    Remediation
    • created a PriorityLevelConfiguration named limit-list-custom that queues requests (assuredConcurrencyShares 5, 16 queues, handSize 4, queueLengthLimit 50)
    • created a FlowSchema that routes list and get requests on pods from the log collector's service account to that priority level
    Action items
    • Submit a pull request adding resource version support to the Kubernetes Rust library
    • Open a pull request to the Vector log collector to address the startup list requests
    • Apply the same flow-control approach to a similar problem found with the Cilium CNI
    Lessons

    A field selector reduces what kube-apiserver returns, not what it reads from etcd: listing the pods of one node still reads every pod in the cluster. A DaemonSet whose pods all list at startup multiplies that by the node count each time kube-apiserver restarts. Where exact freshness is not needed, resourceVersion=0 lets kube-apiserver answer from its cache; where the client cannot set it, API Priority and Fairness can queue the requests so they reach etcd gradually.

  3. Symptoms

    Shortly after a round of changes, loveholidays saw connectivity problems and raised error rates on its aggregation service. The service is a proxy between two other services of more than 100 instances each, handles over 10,000 requests per second continuously and can spike to four times that.

    Trigger

    Three changes together: a change in service architecture, halving the RAM of the nodes that run the aggregation service, and sharding a downstream service, which doubled the number of connections to track.

    Root cause
    Component
    Contributing factor
    Detection

    Rising error rates and climbing connection reset errors in HAProxy, then node_exporter conntrack metrics compared with their limit.

    Remediation
    • moved the aggregation service to nodes with more RAM
    • limited the number of aggregation service pods per node
    Action items
    • Alert when conntrack table use goes above 75%, with (node_nf_conntrack_entries / on (pod) node_nf_conntrack_entries_limit / on (pod) group_right kube_pod_info) > 0.75
    Lessons

    The conntrack limit is tied to node memory, so resizing a node pool silently resizes the connection table, and on GKE the ratio did not match the commonly cited formula. A high-traffic proxy on small nodes can exhaust it, and the symptoms are connection resets and timeouts, so conntrack use needs its own metric and alert.

  4. Symptoms

    A colleague wrote in Slack that his application was taking a long time to deploy. A deployment that normally finishes in minutes had been running for about an hour: about half of the new pods were running and serving traffic, and the other half were Pending.

    Trigger

    The cluster reaching 256 nodes, the most its /16 pod secondary range could hold at 256 addresses per node; every further node creation failed.

    Root cause
    Component
    Contributing factor
    Detection

    A colleague reported in Slack that a deployment was slow; the pending pods' events and the cluster autoscaler status ConfigMap showed the exhausted IP space.

    Remediation
    • lowered the maximum pods per node on selected node pools, cutting IP consumption by about 30%
    • moved some node pools to larger instance types
    Action items
    • Lower the maximum pods per node on node pools that do not run many pods
    • Use larger instance types in some node pools
    Lessons

    In a VPC-native GKE cluster the number of nodes, not the number of pods, uses up the pod range: by default each node reserves 256 addresses, so even a /16 is full at 256 nodes. Maximum pods per node and node size are the practical levers; larger nodes pack better but take more pods down when they fail.

  5. Symptoms

    Users reported that their jobs were not starting, with some sign that image pulls were involved. Many pods across the cluster were in error states related to image pulls, while applications that were already running were not affected.

    Trigger

    A change to the permissions on a storage bucket that one application needed to read. The application could no longer start, and its DaemonSet, running on roughly a thousand nodes of the cluster, went into a crash loop with imagePullPolicy: Always, so every restart pulled the image again although it was already on the node.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that their jobs were not starting; monitoring had not caught it first.

    Remediation
    • replaced the affected NAT instances so registry traffic came from new source IPs
    • reconfigured the static IPs and firewall rules so applications could reach the Cloud SQL database again
    Action items
    • Add an admission webhook that rejects floating image tags, starting with latest
    • Apply the image tag webhook to workload objects only, not to pods, after it blocked pods created by in-cluster controllers
    Lessons

    The speakers' takeaway is to be very careful with DaemonSets in large clusters: they say they had broken everything DaemonSets depend on, including DNS, Vault and the image repository, and that it is very easy to break things when managing them by the thousand. imagePullPolicy: Always made every crash-loop restart pull the image again. Sending all registry traffic through three NAT instances put the whole region behind three source IPs, which the registry rate-limited, and changing those IPs cut the connections to a critical database reached over the internet through them. An admission webhook on pods rejects the pods that controllers in the cluster create, where no user sees the error.

Check your cluster for this

These 12 cases involve CoreDNS and Node pool. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion12 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0048 DNS lookups timed out in a large EKS cluster when CoreDNS hit the 1024 packets-per-second link-local limit, driven by sudo hostname lookups
  4. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  5. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  6. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed
  7. IL-0194 After a kube-apiserver restart, pod LIST requests from every pod of a Vector DaemonSet nearly tripled etcd memory and restarted all master nodes
    Palark2023
  8. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  9. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing
  10. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  11. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  12. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries