  1. Symptoms

    On Friday 19 July 2019 the Grafana Cloud Hosted Prometheus service, which is built on the Cortex project, was down for 26 minutes. New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start.

    Trigger

    An engineer created a new dedicated Cortex cluster for a large customer. Its configuration did not include the new pod priorities, so all its pods got the default medium priority, and the Kubernetes cluster did not have enough free resources to fit it.

    Root cause
    Component
    Contributing factor
    Detection

    New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start of the outage.

    Remediation
    • Scaled up the underlying Kubernetes cluster to fit both the new and the production Cortex clusters
    • Diagnosed and fixed the out-of-memory errors in the authenticating reverse proxies in front of Cortex
    Action items
    • Give the production ingesters the high priority class, which should have been done before medium became the default
    • Have more people review changes to configuration that is global to the cluster
    • Require a design document for every configuration change outside a namespace
    • Automate the sizing of the frontend authenticating reverse proxy so it does not run out of memory under overload
    • Investigate the default backoff and scaling behaviour of Prometheus to prevent a stampeding herd of retries
    Lessons

    Medium should not have become the default priority until the production ingesters had the high priority, and that designation should have reached production sooner. The change was considered too minor for a design document and was only discussed in a GitHub issue; cluster-global configuration needs more scrutiny. On the positive side, once Cortex had enough capacity it recovered by itself, and Grafana Loki helped confirm that the ingesters exited gracefully.

  2. Symptoms

    During a rolling update of a kubelet change in one of Oath's on-premises production clusters, nodes started going NotReady, and soon all nodes in the cluster were NotReady.

    Trigger

    A change to kubelet was rolled out across the nodes of one cluster; on restart, kubelet cleans up transient cgroup files, and a Kubernetes bug in that step left kubelet stuck instead of starting.

    Root cause
    Component
    Contributing factor
    Detection

    Nodes reported NotReady and the eviction graphs climbed while the kubelet rollout was in progress.

    Remediation
    • failed the affected data center over so users were routed to the next available data center
    Action items
    • Run a functional test of kubelet after each upgrade batch and certify it before the next 30% of nodes are updated
    Lessons

    Check kubelet after upgrading it before moving to the next batch; a simple curl against the kubelet API would have caught this. The node controller's eviction throttling and full disruption mode, which the speakers note is not well documented, kept a cluster-wide kubelet failure from evicting every pod.

Check your cluster for this

These 7 cases involve Node pool and AWS VPC CNI. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Capacity exhaustion2 cases

Organisation
  1. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  2. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023

Faulty deployment1 case

  1. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down

Configuration change3 cases

  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours
  2. IL-0019 An EKS Terraform module upgrade shrank node root disks from 100 GB to 20 GB and image pulls failed with no space left on device
  3. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down

Software defect1 case

Organisation
  1. IL-0038 kubelet rollout hit a Kubernetes bug and left every node in a cluster NotReady, triggering mass pod eviction
    Oath2018