  1. Symptoms

    From 2:45 PM PDT on July 30th, 2024, several AWS services in the Northern Virginia (US-EAST-1) Region had higher latency and error rates: CloudWatch Logs, Amazon Data Firehose, the event framework that publishes Amazon S3 events, Amazon ECS, AWS Lambda, Amazon Redshift and AWS Glue. All of them used one internal cell of Amazon Kinesis Data Streams, whose requests had started to see elevated latency and errors.

    Trigger

    At 9:09 AM PDT on July 30th a routine deployment started in one Availability Zone of the Kinesis cell, and taking hosts in and out of service during the deployment set off the failure.

    Root cause
    Component
    Contributing factor
    Remediation
    • Deployed a change that shed load by reducing incoming stream volume from less time-sensitive internal workloads
    • Added capacity to the subsystem that provisions secure connections for Kinesis requests
    • Added more capacity at 6:32 PM PDT to further improve connection provisioning
    Action items
    • Keep the added connection provisioning capacity, load-shedding tooling and changed connection limits in place in US-EAST-1
    • Apply the same changes in every other region that has cells with the new Kinesis Data Streams architecture
    • Update the cell management system to better manage the workload that triggered the issue
  2. Symptoms

    On 19 and 20 October 2022, Linode Object Storage in Newark and Atlanta slowed down, became less available and rate limited many requests with "503 - Slow Down" HTTP responses, after the clusters received extremely high inbound traffic in both request count and bandwidth.

    Trigger

    Extremely high inbound traffic, in both total requests and throughput, reached the Newark and Atlanta Object Storage clusters on 19 and 20 October 2022.

    Root cause
    Component
    Contributing factor
    Remediation
    • Fixed the edge rate limiting so it enforces the advertised 750 requests per second per bucket
    • Adjusted Ceph tunables to stop runaway memory use during high-pressure storage events
    • Moved internal Object Storage components hit by resource contention to less busy, higher-performance infrastructure
    • Adjusted performance tunables on internal components and back-end clusters so customers were not rate limited too early
    Action items
    • Refine throughput and bandwidth throttling
    • Scale up the internal Object Storage infrastructure to spread load more efficiently
    • Look for further hardware performance improvements for the internal Object Storage infrastructure
    • Tune the load balancing algorithms to avoid hotspots in the clusters
    Lessons

    Linode's per-bucket rate limiting at the edge is meant to keep excess load off the back end; when it works as intended, the back-end limits, which throttle every client alike, should never come into play.

Check your cluster for this

These 8 cases involve Object storage and CDN and edge network. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Configuration change1 case

Organisation
  1. IL-0366 Cloud Storage uploads and writes in us-central1 slowed and failed with HTTP 503 as traffic piled onto a few backends

Dependency failure2 cases

  1. IL-0515 Downloads from files.pythonhosted.org failed with intermittent 502 and 503 errors for two weeks, breaking PyPI installs
  2. IL-0343 DNS names under digitaloceanspaces.com stopped resolving, breaking Spaces, Container Registry and the Control Panel

Cloud provider outage2 cases

Contributing factor
–
  1. IL-0357 Up to 22% of Vercel static file requests failed when part of its global cache was lost during the AWS us-east-1 outage
    Vercel2025
  2. IL-0368 PlanetScale's control plane went down and some database branches failed queries during the AWS us-east-1 outage

Operator error1 case

Organisation
  1. IL-0378 All Cloudflare R2 object writes and about 35% of reads failed when the R2 Gateway could not authenticate to storage

Software defect1 case

  1. IL-0535 An internal Kinesis Data Streams cell in US-EAST-1 degraded, raising errors in CloudWatch Logs, S3 events and Lambda

Capacity exhaustion1 case

Organisation
  1. IL-0382 Linode Object Storage in Newark and Atlanta returned 503 Slow Down to all clients under very high inbound traffic
    Linode2022