Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases8 cases

7 to 8 of 8

  1. Symptoms

    An alert fired because some Metrictank instances could not drain their write queue, which meant they could not write to Cassandra. Google had not yet published an incident, but a team member's Discord server, also hosted on GCP, was down, which pointed at GCP; Google confirmed an SSD persistent disk incident about 90 minutes after it began.

    Trigger

    A Google Cloud incident in which SSD persistent disks performed so poorly that many I/O operations failed for an extended period.

    Root cause
    Component
    Contributing factor
    Detection

    An alert that Metrictank write instances could not flush their write queue to Cassandra. Error rates alone rose too slowly to notice quickly, because most queries were served from memory.

    Remediation
    • Added compute nodes hoping new nodes could attach the disks, which did not work
    • Deleted and recreated the Cassandra StatefulSet with an updated pod management policy, so all pods but one started
    • Raised Kafka topic retention to avoid data loss during the long downtime
    • Temporarily added nodes so Metrictank restarts were not slowed by CPU starvation
    • Restarted all Metrictank instances, which took more than 20 hours, so they connected to the new Cassandra IPs
    Action items
    • Re-instantiate the gocql connection in Metrictank when it is detected dead, so it reconnects even when all Cassandra IPs change
    • Fix the Metrictank write-queue deadlock by updating an internal data structure with atomics instead of a lock
    Lessons

    An OrderedReady StatefulSet cannot recover past a single pod whose volume will not attach; when every pod is down, the ordering that protects normal start-up blocks the whole cluster. A client that learns peer addresses only from live peers needs a way to go back to the service name when all peers are replaced at once. A long-tolerated bug with a config workaround can surface at the worst time; this one turned out to have a simple fix. Writing incoming data to a Kafka write-ahead log first meant all data could still be ingested after recovery, and Kafka on non-SSD disks escaped the disk incident. With both Metrictank bugs fixed, the team expects a similar event to take less than 3 hours to recover from instead of 23.

  2. Symptoms

    On the evening of a long-overdue upgrade of a loveholidays production GKE cluster from 1.10.X to 1.12.5-gke.10, planned to take 2 to 2.5 hours, the master upgrade and the first two 7-node NodePools went smoothly. After that the NodePool upgrades slowed to a crawl. Each node is cordoned, drained and upgraded in turn. Even a 14-node cluster at about 5 minutes per node took over an hour, and with about 100 more nodes to go, some of them taking over 15 minutes to drain, the sequential drains were too slow to finish at a reasonable hour.

    Trigger

    A manual upgrade of the GKE masters and NodePools from 1.10.X to 1.12.5-gke.10, two versions at once, on 19 March 2019; GKE's release notes of 14 March had already said that version was no longer available for new clusters or master upgrades because masters showed elevated error rates, but it could still be selected.

    Root cause
    Component
    Contributing factor
    Detection

    The slow drains, zombie nodes and stuck NodePool were seen by the engineer running the upgrade; the broken Ingress was noticed after the upgrade and explained by Google support; the HPA problem was noticed the next day.

    Remediation
    • drained the remaining NodePool nodes ahead of the upgrade with kubectl drain --ignore-daemonsets --delete-local-data
    • deleted the zombie instances from the managed instance group with gcloud compute instance-groups managed delete-instances
    • cancelled the stuck UPGRADE_NODES operation with gcloud beta container operations cancel
    • used kubectl port-forward in place of the broken internal Ingresses
    • scaled down the older of two active ReplicaSets, or triggered a dummy deployment, to bring the HPA back
    Action items
    • Alert when a HorizontalPodAutoscaler is at 70% and at 100% of its capacity
    • Alert when a deployment has had two active ReplicaSets for 30 minutes and for 60 minutes
    • Re-evaluate termination grace periods that were set to arbitrary large values
    • Read the GKE release notes before every cluster upgrade
    • Use auto-upgrade in non-production environments, and manual cluster upgrades with automatic node upgrades in production
    • Keep environments as identical as possible, including resource names
    Lessons

    Read the release notes before upgrading: the target version had been withdrawn five days earlier. Drain time depends on pod configuration, so emptyDir volumes, long grace periods and missing disruption budgets turn a NodePool upgrade into hours. Pre-production only catches problems like the ingress bug if it matches production down to resource names. Auto-upgrades in non-production surface problems early, and a mix of manual cluster upgrades and automatic node upgrades in production keeps clusters current without much effort.

Check your cluster for this

These 8 cases involve Application database and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Cloud provider outage8 cases

  1. IL-0119 ChatGPT web service pods crash-looped on failing health checks after a Cosmos DB failure, leaving too few healthy pods to serve the web layer
    OpenAI2025
  2. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU
  3. IL-0145 A power sag and chiller failure in one Australia East availability zone took down the AKS control plane's compute and its non-zone-redundant SQL Database operation queue, blocking AKS create, update and delete operations in Australia East and Australia Southeast
  4. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022
  5. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021
  6. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  7. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage
  8. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA