Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases43 cases

8 to 12 of 43

  1. Symptoms

    GPU nodes for an AI video upscaling job were created normally and reached Ready, and then about 10 to 11 minutes later Karpenter treated each one as unhealthy and replaced it. Every new node went the same way, so the GPU pods kept restarting and the upscaling work could not make progress.

    Trigger

    Enabling Karpenter's node auto-repair feature gate (nodeRepair: true) and then running GPU pods on nodes from the Bottlerocket NVIDIA AMI.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed GPU nodes being replaced repeatedly after running GPU pods, then found the DCGMError message in the node events.

    Remediation
    • Disabled Karpenter node auto-repair by setting the nodeRepair feature gate to false
    Lessons

    Automatic node repair acts on every unhealthy node condition, including AcceleratedHardwareReady, so an image defect that only breaks GPU health monitoring is enough to have every GPU node terminated and recreated in a loop. Before turning on auto-repair, check which conditions it watches and whether the node image reports them correctly. Disabling auto-repair stops the loop at once but is only a temporary measure; installing the missing library or changing the AMI address the cause but cost more on an immutable OS such as Bottlerocket.

  2. Symptoms

    On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.

    Trigger

    On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.

    Root cause
    Component
    Contributing factor
    Detection

    As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.

    Remediation
    • Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
    • Fixed the control plane's periodic job so idle computes were terminated again
    • Restarted the aws-node DaemonSet several times, each with a temporary improvement
    • Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
    • On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
    • Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
    Action items
    • Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
    • Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
    • Change the architecture to support horizontal scaling
    Lessons

    With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.

  3. Symptoms

    On 2025-03-12 from 10:58 UTC, alerts for high backend response times came in, and the MediaWiki deployments mw-api-int, mw-parsoid and mw-jobrunner, which serve MediaWiki for non-user-facing purposes, showed high latency and database errors. The External Storage cluster, whose hosts store the compressed text of wiki page revisions, had a sharp rise in load and connections. The same happened again on 2025-03-13 from 11:15 UTC.

    Trigger

    At 10:44 UTC on 12 March a Scap deployment of the PHP 8.1 rollout for mw-api-int, mw-parsoid and mw-jobrunner was run with the flag -Dbuild_mw_container_image:False; the rollout was deployed with Scap again at 11:15 UTC on 13 March.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts for high backend response times started at 10:58 UTC on 12 March, 14 minutes after the Scap deployment; 2 on-call engineers were paged. The MediaWikiMemcachedHighErrorRate alert that pointed at the cause fired only briefly because its log pipeline was overloaded.

    Remediation
    • Deployed a patch to cirrus-streaming-updater that reduced SUP parallelism
    • Reduced the concurrency of the categoryMembershipChange job in changeprop-jobqueue
    • On 12 March, reverted 1126607 and 1126650 and re-ran Scap
    • On 13 March, rolling-restarted changeprop-jobqueue
    • Rolling-restarted mw-api-int
    • Disabled the categorymembership job in changeprop-jobqueue
    • Reverted 1127476 and 1127478
    • Redeployed mw-api-int to pick up the revert
    • Increased the number of mw-api-int replicas
    • Redeployed mw-jobrunner to pick up the revert
    • Redeployed mw-parsoid to pick up the revert
    Action items
    • Reduce the number of messages sent through channel:Memcached during failures
    • Add helm rollback functionality to Scap
    • Decide whether Scap should update helmfile-defaults when -Dbuild_mw_container_image:False is set
    • Consider removing envvars.inc from MediaWiki images
    • Consider "Why" dashboards that give an overview of a group of related components together with relevant links to follow
    • Coordinate incident responders better
    • Be able to work with MediaWiki developers during incidents
    Lessons

    The write-up puts the weight not on the technical root cause but on why the team could not see, even after the 12 March incident, that three MediaWiki deployments were running without Memcached. Alert dashboards showed what was happening, such as many busy PHP workers, but not why; dashboards linking components that affect each other, such as SQLBlobStore keys and External Storage, would have helped. The alert that pointed in the right direction did not stay firing and would probably have been lost among 78 others. The incident coordinator could not tell who was working on what or who had joined or left, the channels were noisy, the external impact was judged more critical than it was, and trace.wikimedia.org was not used although it might have helped.

  4. Symptoms

    At 08:41 UTC on 18 February 2025, several Grafana Labs application teams noticed that some of their endpoints were no longer available. The investigation quickly found that the load balancers for those endpoints were gone.

    Trigger

    A change to the merge policy of a Crossplane composition, made so that the default TLS policy of the load balancers could be overridden, was applied to development, staging and production at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    Application teams noticed at 08:41 UTC that some of their endpoints were no longer available.

    Remediation
    • rolled back the Crossplane composition change
    • recreated the affected Kubernetes Services so that Kubernetes recreated their load balancers
    Action items
    • Add a CI check that blocks a deployment to more than one wave, so any exception to the dev, staging, canary, production order is caught
    • Give higher priority to a more sophisticated wave design that was already under discussion
    • Enable deletion protection on the load balancers, one layer below Crossplane
    • Enable deletion protection on other critical cloud provider resources
    • Develop the Crossplane Managed Resources exporter for change validation and visibility, now in beta testing within Platform engineering; simulated against the change that caused this outage, it shows a clear diff
    • Complete and test support for reconfiguring the TLS policy so application teams can deploy it
    Lessons

    A change that looked small and low-risk had a side effect that only a full end-to-end test through Crossplane and the cloud provider's load balancer controller would have shown; seeing the intended override work was not that test. Staged rollout and blast-radius limits that exist only as process can be skipped, so Grafana Labs moved to enforce waves in CI and to add deletion protection on the load balancers themselves, beneath the Crossplane layer.

  5. Symptoms

    When MonotaRO raised the share of requests for the remaining endpoints of its backend API sent to EKS from 1% to 25%, Sentry filled with errors saying the API could not reach the database and outside services. The errors were about DNS name resolution, and the traffic had to be shifted back to the EC2 version.

    Trigger

    MonotaRO raised the share of requests for the remaining API endpoints routed by the ALB to the EKS version from 1% to 25%.

    Root cause
    Component
    Contributing factor
    Detection

    Sentry showed a large number of errors about connecting to the database and outside services right after the traffic share was raised.

    Remediation
    • Shifted the requests back to the EC2 version to stop the errors
    • Added an HPA to autoscale the CoreDNS pods as a stopgap, which let the migration to EKS finish
    Action items
    • Set ndots to 1 through dnsConfig in the application Deployments
    • Set cache 600 in the Corefile in the coredns ConfigMap to lengthen the CoreDNS cache TTL
    • Add lameduck 30s to the CoreDNS health plugin so CoreDNS keeps serving while it is scaled in
    • Consider reducing the differences between production and staging, weighed against cost
    Lessons

    MonotaRO assumed that a managed service would not cause problems and so skipped researching other companies' migrations, load testing and monitoring. Staging differed from production in its network layout, so ndots differed between them, and staging databases could not take a high-load test. Looking at the CoreDNS logs and resolv.conf instead of guessing found that ndots:5 made lookups of outside names try every search domain first.

Check your cluster for this

These 43 cases involve Ingress controller and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Configuration change12 cases

  1. IL-0179 With DEBUG logging and synchronous log output, a high-traffic service filled the 64 KB stdout pipe, so request threads blocked in write() while holding database connections and HikariCP ran dry, failing requests in 30-second bursts
  2. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  3. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  4. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  5. IL-0231 Deleting EKS managed node groups also deleted Karpenter's instance profile, and every Stytch worker node shut down
    Stytch2023
  6. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
  7. IL-0442 Older pods on LIFULL's KEEL Kubernetes cluster were preempted all at once and the external error rate spiked
    LIFULL2021
  8. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  9. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  10. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  11. IL-0061 A Terraform pull request merged out of order deleted a production GKE cluster, and recreating it deleted a second one
  12. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files

Capacity exhaustion8 cases

  1. IL-0470 Buildkite notifications were delayed after Prometheus storage filled and EKS notification workers could not autoscale
  2. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  3. IL-0433 Shifting API traffic from EC2 to EKS on Fargate overloaded two CoreDNS pods and caused mass name-resolution errors
  4. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  5. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  6. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  7. IL-0518 gitlab.freedesktop.org on GKE ran short of volume space and a planned 30-minute storage upgrade became a 4-hour outage
  8. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Breaking change in an upgrade2 cases

  1. IL-0097 A cluster autoscaler version bump was incompatible with the one cluster still on Kubernetes 1.33, so no scale-up events fired and new nodes were not created
    2i2c2026
  2. IL-0522 An ingress-nginx chart upgrade deleted the jenkins.io Ingress and Fastly served HTTP/503 errors for hours

Faulty deployment5 cases

  1. IL-0160 A repaired legacy GPU monitoring script sent a firmware query that triggers a race condition in the GPU System Processor of NVIDIA RTX 4000 Ada GPUs, locking up GPU Linodes and LKE worker nodes in several regions
    Linode2026
  2. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  3. IL-0324 Three MediaWiki deployments lost Memcached after a PHP 8.1 rollout and overloaded the External Storage database cluster
  4. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019
  5. IL-0467 Boskos crash-looped after a node drain started it from a buggy StatefulSet image, failing Kubernetes PR jobs for 9 hours

DNS or network fault2 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node

unknown1 case

Organisation
  1. IL-0087 After a cold reboot of RKE2 nodes, pods could not get IP addresses because Multus could not reach the Kubernetes API, and further reboots spread the failure to every node

Operator error2 cases

Organisation
  1. IL-0197 Moving a three-node Elasticsearch StatefulSet to new persistent volumes split the cluster in two, because the Helm chart hardcoded cluster.initial_master_nodes to elasticsearch-0
    Palark2021
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage

Certificate or credential expiry1 case

Organisation
  1. IL-0460 Vault served an expired TLS certificate and almost every GoCardless service pod crash-looped, a 22-minute full outage