  1. Symptoms

    During a rollout of the Grafana Loki distributor Deployment in one Grafana Cloud Logs environment, the write path went down for about 25 minutes. The newly started distributor pods were OOM-killed over and over, never passed their health and readiness checks, and the rollout stopped making progress.

    Trigger

    Step 1 of moving the Loki ring off a separately deployed key-value store onto embedded memberlist added a new label, gossip_ring_member: 'true', to the distributor pods and Service, together with a small config change, and the change required a rollout of the distributors.

    Root cause
    Component
    Contributing factor
    Detection

    The first clue was kubectl get pods and the kube_deployment_status_replicas_updated metric showing that only 16 of 140 distributor pods had been updated.

    Remediation
    • scaled the distributor Deployment out horizontally so the load spread over more pods with the new label and the rollout could continue
    • reverted the migration step to end the outage
    • set service_ignored_labels:: [$._config.gossip_member_label] and passed it to k.util.serviceFor so the label is no longer copied into the Service selector
    Action items
    • Update the function that generates a Service from a Deployment or StatefulSet to handle edge cases, including this one
    Lessons

    A Service whose selector is built by copying every label of a workload changes which pods it matches as soon as a new label is added. During a rollout it then matches only the new pods, which receive all the traffic before there are enough of them. A few errors during a rollout in other environments hid the problem, because those environments gave distributors more memory and could absorb the shift. Manifest diffs kept for every pull request made it possible to see that the Service selector had changed.

  2. Symptoms

    While the old nodes of a GKE cluster were being drained to move workloads to a newly created node pool, none of the services in the cluster could be reached through ingress-nginx any more.

    Trigger

    Cordoning and draining the old node pool removed those nodes from the GCP load balancer backend while the ingress-nginx pods were still running on them.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed during the drain that no service in the cluster was reachable through ingress-nginx.

    Remediation
    • deleted the nginx-ingress-controller pods still running on the old nodes so they were rescheduled on the new, ready nodes
    Lessons

    With externalTrafficPolicy: Local, the load balancer can only reach nodes that run an ingress pod, and cordoned nodes leave the load balancer backend immediately; if the ingress pods stay behind on cordoned nodes, all ingress traffic stops. Before any change that might touch traffic, look twice into the documentation.

  3. Symptoms

    The daily NRE Labs statistics showed lesson activity collapsing, and kubectl could not reach the cluster: `The connection to the server 1.2.3.4:6443 was refused - did you specify the right host or port?`

    Trigger

    Unknown. The liveness probe that kubeadm writes into the etcd static pod manifest (an `etcdctl get foo` against 127.0.0.1:2379, failureThreshold 8, timeoutSeconds 15) started failing. The author first suspected GCP maintenance the night before, but could not reproduce the probe failure by hand and does not know why it began.

    Root cause
    Component
    Contributing factor
    Detection

    The author saw lesson activity drop in the daily NRE Labs statistics during his morning routine.

    Remediation
    • removed the liveness probe section from the kubeadm-generated etcd static pod manifest and applied it between etcd restarts
    Action items
    • Add monitoring, especially for the single-node master
    • Run a basic "down for maintenance" page in Google Cloud Functions that points to Twitter for updates, to redirect to during outages
    Lessons

    Because all of the infrastructure is managed as code, the cluster could be rebuilt quickly, but destroying it before finding the cause also destroyed the evidence. Monitoring matters, especially with a single-node master. Read the restart counts in kubectl output, not just the Running status. Remember the fundamentals instead of expecting the issue to be more complicated than it is, and do not let the urgency of an outage push you into hasty decisions. Put up a maintenance page instead of leaving the site failing halfway.

  4. Symptoms

    A Kubernetes cluster went down after one CronJob kept failing and its pods piled up. Because each failed run kept restarting instead of being replaced by the next one, the pods accumulated into the thousands. The speaker's arithmetic for a job scheduled every minute that fails for three days is 4,320 restarting pods.

    Trigger

    A CronJob kept failing.

    Root cause
    Component
    Contributing factor
    Lessons

    When deploying a CronJob, set its concurrency policy to Replace or Forbid; with the default, failing runs accumulate and restart together. An application should handle a missing dependency with probes and bounded back-off rather than crash in a loop, which also keeps it from hammering a dependency that is already struggling.

  5. Symptoms

    A user reported that pods were starting up and then vanishing. When the cluster operators looked, kubectl get pods and kubectl get nodes returned two different sets of data that alternated back and forth, as if there were two opinions of the cluster's state.

    Trigger

    etcd write latency rose far above the healthy single-digit milliseconds; the speakers say trouble starts once the database sync time crosses double digits or several hundred milliseconds.

    Root cause
    Component
    Contributing factor
    Detection

    A user reported pods starting up and vanishing.

    Remediation
    • restored service on a replacement cluster
    • freed persistent volumes from the old cluster one by one so they could bind in the new cluster
    • updated DNS records that pointed at the old cluster's load balancer names
    Action items
    • Make the Kubernetes API server request quorum reads from etcd
    Lessons

    etcd is extremely sensitive to write latency; once the database sync time crosses double digits of milliseconds, stale reads or badly degraded performance follow. Without quorum reads, a consistent store can still hand out stale data. Documentation for a fast-moving system changes, so read it again regularly. Moving workloads to a new cluster is hard when they hold persistent volumes or when DNS records point at generated load balancer names.

Check your cluster for this

These 14 cases involve Node pool and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause8

Faulty deployment2 cases

  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down

Dependency failure1 case

Organisation
  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop

Capacity exhaustion3 cases

  1. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  2. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  3. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Configuration change4 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout
  4. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Breaking change in an upgrade1 case

Organisation
  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Operator error1 case

Organisation
  1. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe

Software defect1 case

Contributing factor
Organisation
  1. IL-0072 High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state