  1. Symptoms

    After a rolling restart of the Argo CD application-controller, namespaces that several applications shared went into the Terminating state. About 97 applications were then stuck in a Missing/OutOfSync deadlock.

    Trigger

    A manual bulk sync with force: true from the Argo CD UI, run during the window after an application-controller restart, on an application whose manifests declared a namespace whose app.kubernetes.io/instance label pointed to a different application.

    Root cause
    Component
    Contributing factor
    Action items
    • Refile the problem as #29739: a manual force sync hard-replaces shared cluster-scoped resources through a tracking-ID conflict, ignoring Prune=false
    Lessons

    The sync option Prune=false only protects the prune path; it does not stop a force sync from deleting and recreating a resource. When two Argo CD applications declare the same namespace or other cluster-scoped resource, force-syncing the application that does not own the tracking label can delete it at any time.

  2. Symptoms

    From 20:01 UTC on 28 May 2026, Buildkite build and job notifications (GitHub commit status, email, Slack and webhook notifications) reached a subset of customers late. Internal queue latency monitoring showed the delay as queues grew while notification-processing workers stayed underprovisioned.

    Trigger

    The Prometheus service used by Buildkite's EKS autoscaling path ran out of storage, so some EKS-based notification workers could not autoscale while their queues were growing.

    Root cause
    Component
    Contributing factor
    Detection

    Internal queue latency monitoring detected the rising notification delivery latency.

    Remediation
    • Moved the affected notification-processing workloads from EKS back to the ECS-based infrastructure
    • Adjusted scaling configuration and worker counts by hand
    • Completed the rollback and scaled the remaining affected ECS services
    • Increased Prometheus storage capacity and recorded the change in infrastructure as code
    Action items
    • Alert before Prometheus storage exhaustion can affect autoscaling
    • Fix GitHub notification retry behaviour for a class of errors that could cause repeated retries
    • Make the EKS-to-ECS rollback verify destination capacity, autoscaling configuration and traffic movement
    • Review the CPU, memory and storage allocations of EKS control-plane dependencies such as KEDA and Karpenter
    • Move customer-critical workloads to EKS more gradually, with clearer settling periods
    • Improve customer-level monitoring of notification delivery latency to detect customer-impacting regressions earlier
    • Review which notification types sit on customers' scheduling or CI hot path and need tighter latency, separate queueing or specific alerting
    • Update the status page earlier when notification latency is likely to affect customer workflows
    • Describe the customer-visible impact in status page updates, not only the affected internal service
    • Improve internal escalation for customers who report critical CI impact
    Lessons

    Buildkite said recovery took longer than expected because the rollback path from EKS to ECS did not fully handle this failure, and that its public status page did not show the customer-visible impact as quickly or clearly as it should have, since notification latency affects customers differently depending on how their CI and deployment workflows use notifications.

  3. Symptoms

    On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.

    Trigger

    On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.

    Root cause
    Component
    Contributing factor
    Detection

    As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.

    Remediation
    • Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
    • Fixed the control plane's periodic job so idle computes were terminated again
    • Restarted the aws-node DaemonSet several times, each with a temporary improvement
    • Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
    • On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
    • Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
    Action items
    • Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
    • Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
    • Change the architecture to support horizontal scaling
    Lessons

    With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.

  4. Symptoms

    On 21 March 2025, between 21:10 and 21:41 UTC, part of the authentication and authorization requests to Twingate services failed with elevated error rates.

    Trigger

    Twingate saw anomalies in one of its GKE clusters and scaled down the deployments in that cluster to protect the rest of the system, which moved its traffic to the other clusters.

    Root cause
    Component
    Contributing factor
    Detection

    Twingate observed anomalies in one of its GKE clusters at the start of the incident.

    Remediation
    • Reintroduced capacity in the cluster that had been scaled down, so traffic was rebalanced across regions
    Action items
    • Keep working with the cloud provider to find the cause of the unexpected timeouts and of the cluster update's impact
    • Run deployments in all regions with the same number of replicas in the HPA configuration
    • Raise the maximum node counts of the cluster node autoscalers to leave more room to scale up
    • Configure the HPA to scale up faster
  5. Symptoms

    On 15 January 2025, from about 09:55 to 11:36 CET, a database outage at Magic Pages took down customer websites. It began when the founder tried to reconnect a failed third node to the high-availability MySQL cluster and the database server reported ambiguous errors about missing metadata information.

    Trigger

    One of the three nodes of the MySQL cluster went down, and reconnecting it failed with errors about missing metadata information.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the storage server to fix PVC provisioning
    • Let the MySQL nodes restore and sync with each other for about 45 minutes to rebuild the cluster metadata
    • Cleaned up the corrupted cluster metadata
    • Redeployed MySQL Router
    Action items
    • Monitor the health of the storage system more closely
    • Improve the failover procedures for MySQL Router
    • Investigate and fix the status page so it shows reliable information
    Lessons

    The cluster survived the first node failure as designed and lost no data, but its metadata turned out to be a single point of failure. Better monitoring of PVC health could help prevent similar issues, the 45-minute recovery leaves room for improvement, and the status page has to detect failing customer sites reliably.

Check your cluster for this

These 24 cases involve etcd and Kubernetes API server. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause11

Capacity exhaustion10 cases

  1. IL-0471 GitHub Actions runs failed or sat queued for 9 hours after a routine deployment's pod replacement saturated capacity
    GitHub2026
  2. IL-0470 Buildkite notifications were delayed after Prometheus storage filled and EKS notification workers could not autoscale
  3. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  4. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  5. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  6. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  7. IL-0093 Ingress controller pods crash-looped one after another because the leader pod had exhausted its shared memory
  8. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  9. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  10. IL-0503 mybinder.org launches failed after a GKE node ran out of memory and its nginx-ingress proxy pod crash-looped

Software defect2 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Cloud provider outage1 case

Organisation
  1. IL-0542 Twingate authentication and authorization requests failed at higher rates after traffic moved onto a smaller GKE cluster

Dependency failure1 case

Organisation
  1. IL-0489 Rejoining a failed node of Magic Pages' three-node MySQL cluster broke its metadata and took customer websites down

unknown2 cases

  1. IL-0087 After a cold reboot of RKE2 nodes, pods could not get IP addresses because Multus could not reach the Kubernetes API, and further reboots spread the failure to every node
  2. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe

Breaking change in an upgrade2 cases

  1. IL-0230 kube-proxy sync failures during a Kubernetes upgrade corrupted node iptables, and CircleCI jobs stopped starting
  2. IL-0522 An ingress-nginx chart upgrade deleted the jenkins.io Ingress and Fastly served HTTP/503 errors for hours

Configuration change2 cases

  1. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  2. IL-0458 Toolforge Kubernetes API server failed to start after a restart, logging "etcd cluster is unavailable or misconfigured"

Faulty deployment1 case

Organisation
  1. IL-0591 Gitpod workspaces in all regions became IO bound and unresponsive for days after the ws39 workspace cluster release
    Gitpod2022

Certificate or credential expiry1 case

Organisation
  1. IL-0460 Vault served an expired TLS certificate and almost every GoCardless service pod crash-looped, a 22-minute full outage

DNS or network fault1 case

Organisation
  1. IL-0199 A non-essential container exceeding its memory limit made GitHub's production pods unavailable, and their restarts failed because a DNS maintenance change had left the clusters unable to reach the image registry
    GitHub2020

Operator error1 case

Organisation
  1. IL-0506 UC Berkeley DataHub logins failed and students got empty home directories after the JupyterHub database was overwritten