  1. Symptoms

    At 11:48 PM PDT on 19 October 2025, every system that reached DynamoDB in us-east-1 through the public regional endpoint started getting DNS failures and could not connect. This included customer traffic and internal AWS services that depend on DynamoDB. DynamoDB global table replicas in other regions still answered but fell behind in replication to and from us-east-1.

    Trigger

    One DNS Enactor, slowed by unusually high retry delays, applied a much older DNS plan to the regional DynamoDB endpoint just as another Enactor that had applied the newest plan ran its clean-up, which deleted that older plan and with it every IP address of the endpoint.

    Root cause
    Component
    Contributing factor
    Detection

    DNS failures to DynamoDB began immediately at 11:48 PM PDT and the engineering teams of affected AWS services were engaged at once; by 12:38 AM they had identified DynamoDB's DNS state as the source. The later NLB health check problem was detected by monitoring at 6:52 AM.

    Remediation
    • applied temporary mitigations by 1:15 AM that let some internal services reach DynamoDB and repaired key internal tooling
    • restored all DynamoDB DNS information by 2:25 AM through manual operator intervention
    • throttled incoming work and selectively restarted DWFM hosts from 4:14 AM so droplet leases could be re-established
    • reduced the load on Network Manager to bring network configuration propagation times back to normal by 10:36 AM
    • disabled automatic health check failover for NLB at 9:36 AM, and re-enabled it at 2:09 PM after EC2 recovered
    • relaxed the EC2 request throttles from 11:23 AM until all EC2 APIs and launches were normal at 1:50 PM
    Action items
    • Disable the DynamoDB DNS Planner and DNS Enactor automation worldwide
    • Fix the race condition and add protections against applying incorrect DNS plans before re-enabling the DNS automation
    • Add a velocity control to NLB that limits how much capacity a single load balancer can remove when health check failures cause availability zone failover
    • Build an additional EC2 test suite that exercises the DWFM recovery workflow at scale
    • Improve throttling in EC2 data propagation systems so incoming work is rate limited by the size of the waiting queue
    Lessons

    A single DNS record that automation can empty is enough to take a widely used regional endpoint off the network, and every service built on it fails in turn. A check made once at the start of a long operation can be stale by the time the operation writes its result. Recovery of the dependency is not recovery of the dependents: systems that lost state during the outage, such as EC2's droplet leases and network propagation backlog, can collapse under their own catch-up work, and container services that rely on new instance launches keep failing to launch and scale until that work is done.

  2. Symptoms

    Services on the production Amazon EKS cluster behind the idus marketplace threw intermittent errors whose cause was hard to pin down. Calls to external services such as RDS and Redis failed now and then, and whenever DNS traffic spiked, domain lookups answered slowly or failed outright.

    Trigger

    All CoreDNS pods were scheduled onto the same node, and that node's memory usage spiked until it ran out of memory.

    Root cause
    Component
    Contributing factor
    Detection

    The write-up does not say how the full outage was noticed. The earlier DNS trouble showed up as intermittent service errors, and investigating failed calls to RDS and Redis led to DNS resolution failures.

    Remediation
    • deployed NodeLocal DNSCache as a DaemonSet in front of CoreDNS
    • added a PodDisruptionBudget (maxUnavailable 1) and topologySpreadConstraints across zones for CoreDNS
    • lowered ndots from 5 to 2 with dnsConfig in the Deployments
    Lessons

    The CoreDNS setup that EKS creates by default (two pods) can be enough for a small or development cluster but becomes a bottleneck in a large production cluster, and DNS is a single point of failure that needs high availability and room to scale. Tuning the CoreDNS cache and buffer size only relieved the symptoms; the real load came from the extra queries that ndots:5 generates for external names. A CoreDNS pod without a memory limit can share a node's fate with everything else on it.

  3. Symptoms

    From 17 October 2024, packets through the vSwitch that joined Namespace's bare metal machines at one provider in the fra3 region were dropped at random. Retries in TCP, QUIC and the Namespace control plane hid most of it, but the SLO error budget for latency targets on key interactions began to burn.

    Trigger

    Random packet drops on the bare metal provider's vSwitch from 17 October 2024; for the second outage, a rate of Kubernetes changes that the slow NVMe on one control plane node could no longer keep up with.

    Root cause
    Component
    Contributing factor
    Detection

    SLO-based monitoring of latency targets showed the error budget burning while retries hid the individual packet drops.

    Remediation
    • diverted all customer traffic from fra3 to other regions
    • connected each provider machine to the zrh1 cluster over Wireguard instead of the vSwitch
    • repaved every fra3 machine with a new identity, certificates and encryption-at-rest keys, dropping regional caches to recover faster
    • cloned existing datasets in a more distributed way to speed up repaving the machines
    • added machines back to the new region in batches and returned the region to the compute pool
    • redirected workloads away from zrh1 during the second outage
    • cloned the failing control plane node's key state to a higher-capacity node that took over its role and IP address
    Action items
    • Credit all instances that ran during the outages back to customers
    • Build up backup regions and solutions so a similar event has options that do not affect customers
    Lessons

    Running hot with a delayed hardware delivery left no room to take a region out, so fixing a provider network fault turned into a global capacity shortage. After one outage the team was anchored on its cause and first looked for network problems in the second outage, which had a different cause: a control plane node whose disk could not keep up with the Kubernetes change rate.

  4. Symptoms

    From 22:25 to 22:50 UTC every DigitalOcean service in the SFO3 region had network connectivity problems, as traffic between the datacenter and the backbone dropped. Traffic through the router was back by 22:30 and SFO3's control plane systems had reconnected by 22:50, and most services recovered then.

    Trigger

    Most of the line cards on one SFO3 core router rebooted at the same time at 22:21 UTC because of hardware errors on the device.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • The crashed line cards came back online and traffic on the core router was restored
    • Manually recycled all affected nodes across the SFO3 DOKS fleet
    Action items
    • Work with the router vendor's support team to find the root cause of the line card crash
    • Upgrade software on the core routers in SFO3
    • Raise thresholds for automated remediation so affected nodes are restored without manual action
    Lessons

    A short network fault can leave Kubernetes nodes broken long after the network itself is healthy, when the guest networking on the machines does not recover by itself. Checking node health and the API servers after the network returns, and having automated remediation that is allowed to replace many nodes at once, shortens that tail.

  5. Symptoms

    When traffic changed sharply, CoreDNS came under heavy load, and the cluster saw network problems and a sudden rise in latency. The horizontal pod autoscaler then added pods, database connections surged, and the impact spread to the whole service.

    Trigger

    Sharp changes in traffic loaded the small number of CoreDNS pods beyond what they could handle.

    Root cause
    Component
    Contributing factor
    Remediation
    • Set up the Cluster Proportional Autoscaler for CoreDNS with nodesPerReplica and coresPerReplica chosen for the instance types in use
    • Spread CoreDNS with soft topologySpreadConstraints (ScheduleAnyway) instead of anti-affinity so Karpenter could consolidate nodes
    • Added alert thresholds on CoreDNS error rate, panics, request duration and request rate
    • Deployed NodeLocal DNSCache so each node answers DNS from a local cache and forwards misses to the main CoreDNS
    Lessons

    A fixed, small number of CoreDNS pods cannot follow a cluster whose nodes and pods change quickly with traffic, and the damage spreads: DNS latency triggers autoscaling, which in turn floods the database with connections. Simply adding many CoreDNS replicas created a different problem, because with tainted nodes and a maxSkew: 1 spread constraint the pods piled onto a few nodes and blocked Karpenter consolidation. Scaling CoreDNS in proportion to the cluster and putting a DNS cache on every node handled both.

Check your cluster for this

These 17 cases involve kubelet and CoreDNS. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Capacity exhaustion6 cases

  1. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  2. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  3. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  4. IL-0445 Chatwork's service on EKS became unstable as conntrack tables on some nodes overflowed and connections were dropped
  5. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  6. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down

Software defect6 cases

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  2. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  3. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  4. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  5. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  6. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver

Cloud provider outage1 case

Organisation
  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU

DNS or network fault2 cases

  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node

Breaking change in an upgrade1 case

Organisation
  1. IL-0230 kube-proxy sync failures during a Kubernetes upgrade corrupted node iptables, and CircleCI jobs stopped starting

Configuration change1 case

Organisation
  1. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx