  1. Symptoms

    On 20 May 2026 a subset of Buildkite customers saw delays in notification delivery, build dispatch and the metrics services. The status page first reported delays to notifications for all customers and later narrowed it to a subset of customers.

    Trigger

    Autoscaling during Buildkite's migration of production services from AWS Fargate to AWS EKS raised the number of pods that Prometheus tracked, and with it the memory the Prometheus server needed.

    Root cause
    Component
    Contributing factor
    Remediation
    • Moved the load of the affected services back to AWS Fargate by following prepared documentation
    • Scaled up the services of a few customers with very large backlogs further by hand
    Action items
    • Upsize the underlying system nodes
    • Set higher requests and limits for the Prometheus server so it can handle more load
    • Review all new EKS resources and set any missing requests and limits
    • Add observability and monitors for EKS pod and node health
  2. Symptoms

    On 2025-03-12 from 10:58 UTC, alerts for high backend response times came in, and the MediaWiki deployments mw-api-int, mw-parsoid and mw-jobrunner, which serve MediaWiki for non-user-facing purposes, showed high latency and database errors. The External Storage cluster, whose hosts store the compressed text of wiki page revisions, had a sharp rise in load and connections. The same happened again on 2025-03-13 from 11:15 UTC.

    Trigger

    At 10:44 UTC on 12 March a Scap deployment of the PHP 8.1 rollout for mw-api-int, mw-parsoid and mw-jobrunner was run with the flag -Dbuild_mw_container_image:False; the rollout was deployed with Scap again at 11:15 UTC on 13 March.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts for high backend response times started at 10:58 UTC on 12 March, 14 minutes after the Scap deployment; 2 on-call engineers were paged. The MediaWikiMemcachedHighErrorRate alert that pointed at the cause fired only briefly because its log pipeline was overloaded.

    Remediation
    • Deployed a patch to cirrus-streaming-updater that reduced SUP parallelism
    • Reduced the concurrency of the categoryMembershipChange job in changeprop-jobqueue
    • On 12 March, reverted 1126607 and 1126650 and re-ran Scap
    • On 13 March, rolling-restarted changeprop-jobqueue
    • Rolling-restarted mw-api-int
    • Disabled the categorymembership job in changeprop-jobqueue
    • Reverted 1127476 and 1127478
    • Redeployed mw-api-int to pick up the revert
    • Increased the number of mw-api-int replicas
    • Redeployed mw-jobrunner to pick up the revert
    • Redeployed mw-parsoid to pick up the revert
    Action items
    • Reduce the number of messages sent through channel:Memcached during failures
    • Add helm rollback functionality to Scap
    • Decide whether Scap should update helmfile-defaults when -Dbuild_mw_container_image:False is set
    • Consider removing envvars.inc from MediaWiki images
    • Consider "Why" dashboards that give an overview of a group of related components together with relevant links to follow
    • Coordinate incident responders better
    • Be able to work with MediaWiki developers during incidents
    Lessons

    The write-up puts the weight not on the technical root cause but on why the team could not see, even after the 12 March incident, that three MediaWiki deployments were running without Memcached. Alert dashboards showed what was happening, such as many busy PHP workers, but not why; dashboards linking components that affect each other, such as SQLBlobStore keys and External Storage, would have helped. The alert that pointed in the right direction did not stay firing and would probably have been lost among 78 others. The incident coordinator could not tell who was working on what or who had joined or left, the channels were noisy, the external impact was judged more critical than it was, and trace.wikimedia.org was not used although it might have helped.

  3. Symptoms

    Every service in the homelab Kubernetes cluster stopped answering: the V-Rising server, Grafana, Jellyfin and Linkding were all unreachable, and the Kubernetes API was down, so the cluster could not be managed at all. The outage was found by hand, about 3 hours after it began, when someone tried to use the services.

    Trigger

    A power outage forced the Kubernetes master node to reboot.

    Root cause
    Component
    Contributing factor
    Detection

    Manually, when someone tried to access the services; there were no automated alerts.

    Remediation
    • Connected a monitor to the master node and read the boot logs, which showed the kernel panic
    • Booted the previous kernel version, which brought the system back
    • Removed the broken Nvidia packages with sudo apt-get remove --purge '^nvidia-.*' and ran sudo dpkg --configure -a
    • Found remaining broken packages with dpkg -l | grep -v ^ii and removed them by hand
    • Ran sudo apt-get install -f and reinstalled linux-headers-$(uname -r)
    • Rebooted and confirmed the kernel panic was gone
    Action items
    • Make sure GPU driver installations fully succeed, or revert immediately when they fail
    • Move the cluster to a high-availability control plane
    • Expose the Kubernetes API through a load balancer in the HA setup
    • Set up a ticketing system to record incidents and their resolution
    • Write predefined troubleshooting workflows to shorten response time
    • Add infrastructure monitoring such as Prometheus and Grafana
    • Add blackbox HTTP and TCP checks from outside the cluster for critical services
    Lessons

    A driver installation that fails half-way can leave kernel packages broken without any visible effect until the next reboot, which may come weeks later and at the worst time. A failed DKMS build should be fixed or reverted at once. With a single master node and no monitoring from outside the cluster, one unbootable machine meant a total outage that nobody was told about; the fix itself was simple once the boot logs were seen.

  4. Symptoms

    Kibana stopped showing new application logs at 13:45. At 14:27 a user told the Cloud Platform team in the #ask-cloud-platform channel that Kibana had received no logs since then.

    Trigger

    OpenSearch ran out of disk space and index writes were blocked.

    Root cause
    Component
    Contributing factor
    Detection

    A user reported in #ask-cloud-platform at 14:27 that Kibana had received no logs since 13:45. The report records 12:10, when the ClusterIndexWritesBlocked alert first fired, as the first detection.

    Remediation
    • restarted all fluent-bit containers (logs flowed for a few minutes, then the error came back)
    • increased OpenSearch disk space from 8000 to 12000
    • configured fluent-bit to stop sending logs to OpenSearch while the root cause was investigated
    Action items
    • Look into index dating issues in OpenSearch and Elasticsearch
    • Add high-priority alerts for Elasticsearch and OpenSearch
    • Re-introduce OpenSearch into live logging
    • Investigate the fluent-bit "failed to flush chunk" error
  5. Symptoms

    After an upgrade of the kube-prometheus-stack Helm chart, several pods stayed not ready. Among them was prometheus-prometheus-operator-prometheus-0, showing 3/4 Running and a recent termination.

    Trigger

    During the kube-prometheus-stack Helm chart upgrade, Prometheus had to replay its write-ahead log on startup, and the replay needed more memory than its limit allowed.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed pods not ready after the Helm chart upgrade and found the OOMKilled termination with kubectl describe pod.

    Remediation
    • ran promtool tsdb analyze inside the Prometheus pod to find high-cardinality metrics such as haproxy_server_http_responses_total
    Action items
    • Verify that the memory overhead during WAL replay stays within acceptable limits, for example 10 to 15%, and do not run Prometheus close to its memory limit
    • Optimise storage, scraping and remote write configuration and upgrade to newer Prometheus releases
    • Recover automatically from OOM crash loops, for example by deleting the WAL on OOM events
    • Enforce scrape limits so Prometheus stops scraping targets when memory use passes a threshold
    Lessons

    Size Prometheus for its restart, not only for steady state: WAL replay can need far more memory than normal running, and a Prometheus that already runs near its limit can be OOM-killed during the replay. Much of Prometheus memory use comes from cardinality, which promtool tsdb analyze can measure even when Prometheus itself is down.

Check your cluster for this

These 22 cases involve Prometheus and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Dependency failure1 case

Organisation
  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026

Capacity exhaustion11 cases

  1. IL-0548 Buildkite's EKS Prometheus server was killed for memory again and again, so services stopped scaling and jobs lagged
  2. IL-0042 Application logs stopped reaching Elasticsearch and OpenSearch for hours and were lost when OpenSearch ran out of disk space
  3. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  4. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed
  5. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  6. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  7. IL-0043 Application logs missing in Kibana after a newer Fluent Bit version changed its chunk drop strategy
  8. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  9. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020
  10. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  11. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries

Faulty deployment1 case

  1. IL-0324 Three MediaWiki deployments lost Memcached after a PHP 8.1 rollout and overloaded the External Storage database cluster

Software defect2 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0041 fluent-bit silently stopped shipping application logs from one node to Elasticsearch

unknown1 case

Component
Contributing factor
–
  1. IL-0045 Prometheus on the live cluster restarted several times after readiness probe failures, leaving gaps in metrics

Breaking change in an upgrade2 cases

  1. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023
  2. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Configuration change2 cases

Organisation
  1. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  2. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Operator error1 case

  1. IL-0089 A test cluster deletion script run with the kube context pointing at the live-1 production cluster deleted its ingress controller, monitoring, logging, cert-manager, kiam and external-dns

Cloud provider outage1 case

Contributing factor
Organisation
  1. IL-0505 kubectl logs failed on GKE with "No SSH tunnels currently open" and mybinder.org build logs stopped reaching users