  1. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

  2. Symptoms

    On 13 March 2025 practically every pod of Nebius Managed Services for Kubernetes in the eu-west1 region lost network connectivity for at least some time between 13:36 and 18:11 UTC. Packets for the affected IP alias routes were not processed by the data plane. The eu-north1 region was not affected.

    Trigger

    A release of a VPC control plane component in eu-west1, deployed to canaries from 13:36 UTC and to all other nodes from 14:35 UTC, changed route distinguisher values for a new feature. The change made a long-standing bug in the handling of route announcements take effect for the update messages of Managed Kubernetes pods.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the host VPC component on the affected nodes one node at a time
    • Restarted the host VPC component on the remaining nodes in parallel once the restart was known to fix the problem
    Action items
    • Fix the bug in the VPC host component itself
    • Add an alert on a diverging number of routes
    • Add an alert on the number of drops in the data plane
    • Develop a way to reset endpoints without restarting the host VPC component
    • Move the VPC's persistent e2e test virtual machines to canary hosts
    • Add persistent e2e tests for Managed Services for Kubernetes
    • Run e2e tests more often
    • Add a deployment stage in which non-critical internal services receive updates first
    Lessons

    The failure needed both an existing IP alias at release time and a particular order of node updates, and neither the testing installation nor the canaries met both, so neither caught it. Missing alerts on technical metrics that deviate from normal, here the number of routes and the number of drops, made the response much slower.

  3. Symptoms

    Every service in the homelab Kubernetes cluster stopped answering: the V-Rising server, Grafana, Jellyfin and Linkding were all unreachable, and the Kubernetes API was down, so the cluster could not be managed at all. The outage was found by hand, about 3 hours after it began, when someone tried to use the services.

    Trigger

    A power outage forced the Kubernetes master node to reboot.

    Root cause
    Component
    Contributing factor
    Detection

    Manually, when someone tried to access the services; there were no automated alerts.

    Remediation
    • Connected a monitor to the master node and read the boot logs, which showed the kernel panic
    • Booted the previous kernel version, which brought the system back
    • Removed the broken Nvidia packages with sudo apt-get remove --purge '^nvidia-.*' and ran sudo dpkg --configure -a
    • Found remaining broken packages with dpkg -l | grep -v ^ii and removed them by hand
    • Ran sudo apt-get install -f and reinstalled linux-headers-$(uname -r)
    • Rebooted and confirmed the kernel panic was gone
    Action items
    • Make sure GPU driver installations fully succeed, or revert immediately when they fail
    • Move the cluster to a high-availability control plane
    • Expose the Kubernetes API through a load balancer in the HA setup
    • Set up a ticketing system to record incidents and their resolution
    • Write predefined troubleshooting workflows to shorten response time
    • Add infrastructure monitoring such as Prometheus and Grafana
    • Add blackbox HTTP and TCP checks from outside the cluster for critical services
    Lessons

    A driver installation that fails half-way can leave kernel packages broken without any visible effect until the next reboot, which may come weeks later and at the worst time. A failed DKMS build should be fixed or reverted at once. With a single master node and no monitoring from outside the cluster, one unbootable machine meant a total outage that nobody was told about; the fix itself was simple once the boot logs were seen.

  4. Symptoms

    On 15 January 2025, from about 09:55 to 11:36 CET, a database outage at Magic Pages took down customer websites. It began when the founder tried to reconnect a failed third node to the high-availability MySQL cluster and the database server reported ambiguous errors about missing metadata information.

    Trigger

    One of the three nodes of the MySQL cluster went down, and reconnecting it failed with errors about missing metadata information.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the storage server to fix PVC provisioning
    • Let the MySQL nodes restore and sync with each other for about 45 minutes to rebuild the cluster metadata
    • Cleaned up the corrupted cluster metadata
    • Redeployed MySQL Router
    Action items
    • Monitor the health of the storage system more closely
    • Improve the failover procedures for MySQL Router
    • Investigate and fix the status page so it shows reliable information
    Lessons

    The cluster survived the first node failure as designed and lost no data, but its metadata turned out to be a single point of failure. Better monitoring of PVC health could help prevent similar issues, the 45-minute recovery leaves room for improvement, and the status page has to detect failing customer sites reliably.

  5. Symptoms

    Alerts fired at 3:13 PM PST on 11 December 2024, and from 3:16 PM every OpenAI service was significantly degraded or completely unavailable, including ChatGPT, the API and Sora. The status page reported API calls returning errors and difficulties logging in to platform.openai.com and ChatGPT. Customer impact peaked at 3:40 PM.

    Trigger

    At 2:23 PM PST a change introducing a new telemetry service, which collects detailed Kubernetes control plane metrics, was merged and the deployment pipeline started. Between 2:51 PM and 3:20 PM the change was applied to all clusters.

    Root cause
    Component
    Contributing factor
    Detection

    OpenAI's detection tools worked: alerts fired at 3:13 PM PST, a few minutes before customer impact began at 3:16 PM, and the root cause was identified at 3:16 PM.

    Remediation
    • Scaled clusters down to reduce the total Kubernetes API load
    • Blocked network access to the Kubernetes admin APIs so no new expensive requests arrived
    • Scaled up the Kubernetes API servers
    • Removed the telemetry service once enough control was back
    • Moved traffic from impacted clusters to healthy ones
    • Intervened manually in clusters where simultaneous resource downloads saturated resource limits
    Action items
    • Put every infrastructure configuration change through a phased rollout with continuous monitoring of both the service workloads and the clusters, including the Kubernetes control plane
    • Run fault injection tests in which the data plane runs without the control plane for longer, and tests that roll out bad changes on purpose to check detection and rollback
    • Build break-glass mechanisms so engineers can reach the Kubernetes API servers in any circumstances
    • Decouple the Kubernetes data plane from the control plane so that service discovery for critical workloads does not depend on the control plane
    • Speed up recovery with better caching and dynamic rate limiters for resources needed at cluster startup, and regular drills that rapidly replace an entire cluster
    Lessons

    Several systems and processes failed at once and interacted in unexpected ways: tests did not catch the change's effect on the Kubernetes control plane, DNS caching put a delay between the change and the failures, and being locked out of the control plane made remediation very slow. Because service discovery used Kubernetes DNS, the control plane was carrying load for product traffic even though the data plane was meant to be independent of it.

Check your cluster for this

These 52 cases involve kubelet and Kubernetes API server. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Capacity exhaustion16 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  3. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  4. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  5. IL-0413 LLM inference engines timed out or ran out of resources under load in about 60% of 156 severe incidents at Microsoft
  6. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  7. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  8. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  9. IL-0043 Application logs missing in Kibana after a newer Fluent Bit version changed its chunk drop strategy
  10. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  11. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  12. IL-0401 Prow jobs on the k8s-prow-build GKE cluster failed and merges stalled as nodes hit IOPS throttling and kernel panics
  13. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  14. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  15. IL-0518 gitlab.freedesktop.org on GKE ran short of volume space and a planned 30-minute storage upgrade became a 4-hour outage
  16. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Dependency failure3 cases

  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0489 Rejoining a failed node of Magic Pages' three-node MySQL cluster broke its metadata and took customer websites down
  3. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Configuration change13 cases

  1. IL-0512 xpro.mit.edu returned 503 for an hour when its Kubernetes/APISIX origin certificate expired after renewal failed
  2. IL-0200 Newly provisioned Kubernetes nodes ran an incompatible etcd version and broke cluster consensus in several GitHub production clusters, causing 5XX errors on Git operations and page loads
    GitHub2026
  3. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  4. IL-0068 Anonymous access to the Kubernetes API server used to plant a ClusterRoleBinding backdoor and a cryptominer DaemonSet
  5. IL-0116 A CNI configuration change incompatible with a hardware variant that exists only in production cut network connectivity in an OpenAI GPU cluster and took text-davinci-003 fully down
    OpenAI2023
  6. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  7. IL-0461 Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNS
  8. IL-0111 Switching the main Kubernetes ingress controller from Traefik v1 to v2 stopped X-Forwarded headers being passed, which broke the Okta login flow for every service using Okta and stopped DFDS online bookings for over an hour
    DFDS2021
  9. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  10. IL-0365 A Terraform change to auto-scaling groups detached all worker nodes from both ALBs and cut off every cluster service
    DFDS2020
  11. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node
  12. IL-0052 A cryptocurrency miner ran on every node of the development and staging clusters through a public, unauthenticated Weave Scope dashboard
  13. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Breaking change in an upgrade5 cases

  1. IL-0405 An expired AWS Load Balancer Controller webhook certificate left no healthy targets and took BSEE SaaS down
  2. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced
  3. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023
  4. IL-0230 kube-proxy sync failures during a Kubernetes upgrade corrupted node iptables, and CircleCI jobs stopped starting
  5. IL-0522 An ingress-nginx chart upgrade deleted the jenkins.io Ingress and Fastly served HTTP/503 errors for hours

Faulty deployment2 cases

  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  2. IL-0086 A deployment meant for a CircleCI test Kubernetes cluster also removed Traefik and Calico resources from the production cluster, taking down the CircleCI UI and runner.circleci.com

Software defect8 cases

  1. IL-0233 A VPC control plane release broke IP alias routes in Nebius eu-west1, and Managed Kubernetes pods lost connectivity
    Nebius2025
  2. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  3. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  4. IL-0403 mybinder.org could not create pods for hours as the GKE gke-resource-quotas quota wrongly reported 15k pods in use
  5. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods
    Airbnb2020
  6. IL-0041 fluent-bit silently stopped shipping application logs from one node to Elasticsearch
  7. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  8. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Certificate or credential expiry3 cases

  1. IL-0107 Kyverno stuck in a crash loop behind a webhook with failurePolicy fail blocked every change to Kubernetes Service objects for 88 minutes
    DFDS2022
  2. IL-0521 AKS pods could not mount volumes and new nodes got no CNI network interface after the cluster service principal expired
  3. IL-0460 Vault served an expired TLS certificate and almost every GoCardless service pod crash-looped, a 22-minute full outage

Cloud provider outage1 case

Organisation
  1. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe