  1. Symptoms

    On Friday 19 July 2019 the Grafana Cloud Hosted Prometheus service, which is built on the Cortex project, was down for 26 minutes. New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start.

    Trigger

    An engineer created a new dedicated Cortex cluster for a large customer. Its configuration did not include the new pod priorities, so all its pods got the default medium priority, and the Kubernetes cluster did not have enough free resources to fit it.

    Root cause
    Component
    Contributing factor
    Detection

    New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start of the outage.

    Remediation
    • Scaled up the underlying Kubernetes cluster to fit both the new and the production Cortex clusters
    • Diagnosed and fixed the out-of-memory errors in the authenticating reverse proxies in front of Cortex
    Action items
    • Give the production ingesters the high priority class, which should have been done before medium became the default
    • Have more people review changes to configuration that is global to the cluster
    • Require a design document for every configuration change outside a namespace
    • Automate the sizing of the frontend authenticating reverse proxy so it does not run out of memory under overload
    • Investigate the default backoff and scaling behaviour of Prometheus to prevent a stampeding herd of retries
    Lessons

    Medium should not have become the default priority until the production ingesters had the high priority, and that designation should have reached production sooner. The change was considered too minor for a design document and was only discussed in a GitHub issue; cluster-global configuration needs more scrutiny. On the positive side, once Cortex had enough capacity it recovered by itself, and Grafana Loki helped confirm that the ingesters exited gracefully.

Check your cluster for this

These 13 cases involve Node pool and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Capacity exhaustion5 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0471 GitHub Actions runs failed or sat queued for 9 hours after a routine deployment's pod replacement saturated capacity
    GitHub2026
  3. IL-0465 IONOS Container Registry image pushes and pulls failed with 504 Gateway Timeout
  4. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  5. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023

Configuration change2 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down

Breaking change in an upgrade1 case

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours

Cloud provider outage2 cases

  1. IL-0542 Twingate authentication and authorization requests failed at higher rates after traffic moved onto a smaller GKE cluster
  2. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU

Faulty deployment1 case

  1. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down

Software defect1 case

Organisation
  1. IL-0495 HubSpot's internal load balancers on Kubernetes were falsely marked unhealthy and the rest collapsed under the traffic

Operator error1 case

Organisation
  1. IL-0115 One of OpenAI's three production AKS clusters went offline through a human error, and rebuilding it took 10½ hours because an AKS Kubernetes upgrade broke the ingress and AKS cannot be downgraded
    OpenAI2022