  1. Symptoms

    Users reported that their jobs were not starting, with some sign that image pulls were involved. Many pods across the cluster were in error states related to image pulls, while applications that were already running were not affected.

    Trigger

    A change to the permissions on a storage bucket that one application needed to read. The application could no longer start, and its DaemonSet, running on roughly a thousand nodes of the cluster, went into a crash loop with imagePullPolicy: Always, so every restart pulled the image again although it was already on the node.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that their jobs were not starting; monitoring had not caught it first.

    Remediation
    • replaced the affected NAT instances so registry traffic came from new source IPs
    • reconfigured the static IPs and firewall rules so applications could reach the Cloud SQL database again
    Action items
    • Add an admission webhook that rejects floating image tags, starting with latest
    • Apply the image tag webhook to workload objects only, not to pods, after it blocked pods created by in-cluster controllers
    Lessons

    The speakers' takeaway is to be very careful with DaemonSets in large clusters: they say they had broken everything DaemonSets depend on, including DNS, Vault and the image repository, and that it is very easy to break things when managing them by the thousand. imagePullPolicy: Always made every crash-loop restart pull the image again. Sending all registry traffic through three NAT instances put the whole region behind three source IPs, which the registry rate-limited, and changing those IPs cut the connections to a critical database reached over the internet through them. An admission webhook on pods rejects the pods that controllers in the cluster create, where no user sees the error.

  2. Symptoms

    On Friday, January 18, Moonlight's API began returning occasional errors that looked like connection problems with its Redis database. The API checks Redis on every authenticated request to validate the session. At the same time the Kubernetes monitoring reported some nodes and pods as unresponsive.

    Trigger

    The Kubernetes scheduler put several CPU-heavy pods on the same node, including all three replicas of the website and the server-side rendering pods.

    Root cause
    Component
    Contributing factor
    Detection

    API errors that looked like Redis connectivity problems, and Kubernetes monitoring that showed nodes and pods as unresponsive. Google Cloud Support later found the link between sustained 100% CPU and kernel panics.

    Remediation
    • added anti-affinity rules to all major deployments so their pods spread across nodes
    Action items
    • Keep working with Google Cloud support to find and fix the cause of the node kernel panics
    Lessons

    Three replicas give no fault tolerance if the scheduler places them all on one node; anti-affinity rules make the spread explicit. A node failure that comes from the workload itself moves with the workload when the scheduler reschedules it.

  3. Symptoms

    The daily NRE Labs statistics showed lesson activity collapsing, and kubectl could not reach the cluster: `The connection to the server 1.2.3.4:6443 was refused - did you specify the right host or port?`

    Trigger

    Unknown. The liveness probe that kubeadm writes into the etcd static pod manifest (an `etcdctl get foo` against 127.0.0.1:2379, failureThreshold 8, timeoutSeconds 15) started failing. The author first suspected GCP maintenance the night before, but could not reproduce the probe failure by hand and does not know why it began.

    Root cause
    Component
    Contributing factor
    Detection

    The author saw lesson activity drop in the daily NRE Labs statistics during his morning routine.

    Remediation
    • removed the liveness probe section from the kubeadm-generated etcd static pod manifest and applied it between etcd restarts
    Action items
    • Add monitoring, especially for the single-node master
    • Run a basic "down for maintenance" page in Google Cloud Functions that points to Twitter for updates, to redirect to during outages
    Lessons

    Because all of the infrastructure is managed as code, the cluster could be rebuilt quickly, but destroying it before finding the cause also destroyed the evidence. Monitoring matters, especially with a single-node master. Read the restart counts in kubectl output, not just the Running status. Remember the fundamentals instead of expecting the issue to be more complicated than it is, and do not let the urgency of an outage push you into hasty decisions. Put up a maintenance page instead of leaving the site failing halfway.

  4. Symptoms

    At 14:10 an engineer deployed a change to a service that Monzo's current account needs to process payments, and every request to that service started to fail. Current account customers saw payment failures; the prepaid card was not affected at first because it does not use that service. The change was rolled back at 14:12, but the errors continued.

    Trigger

    At 14:10 an engineer deployed a change to a service needed to process current account payments. Two weeks earlier the etcd cluster had been upgraded and grown from three to nine nodes, and one day earlier another team had scaled a new service down to zero replicas while leaving its Kubernetes service in place.

    Root cause
    Component
    Contributing factor
    Detection

    Payment failures began right after the 14:10 deploy. The team rolled back at 14:12 and declared an outage internally at 14:16. At 15:13, when no service could serve requests, practically all automated alerts fired.

    Remediation
    • Rolled back the payments service change (the errors continued)
    • Activated internal backup processes so most customers could still use their card
    • Restarted all linkerd instances (this made the outage worse)
    • Restarted the three Kubernetes API server processes so replacement linkerd instances could start
    • Began deploying a newer linkerd version with the fix for empty services
    • Deleted the Kubernetes service that had no endpoints, which let linkerd load service discovery again
    Action items
    • Fix the bug in Kubernetes that can trigger timeouts after a cluster reconfiguration
    • Roll out a new version of linkerd that fixes the parsing error
    • Create better health checks, dashboards and alerts for the affected components so they give clearer signals about what is wrong and prevent human error
    • Improve procedures to communicate outages internally and externally as clearly and quickly as possible
    Lessons

    A large failure in a distributed system can be very hard to understand, and well-meant human action can compound it, as restarting every linkerd instance did here by exposing a second incompatibility. Because Monzo deploys often and its network changes constantly, the deployment and request-routing systems have to be trustworthy. Monzo committed to publishing a similar post-mortem for any incident of this severity.

  5. Symptoms

    While running the CI process on a local machine to test an application Helm chart, the SRE lead watched the pods with watch kubectl get pods. All pods reached Running, and then some went back to Pending. Two hours later the problem had grown and some pods showed the phase Unknown.

    Trigger

    A CI run installed the application's Helm charts for all four markets (Efritin.com, Tonaton.com, Ikman.lk and Bikroy.com) on the nonproduction cluster at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The SRE lead saw pods go from Running back to Pending while watching kubectl get pods during the CI run; no monitoring raised an alert, even when all three workers were not ready.

    Remediation
    • terminated the three worker nodes and let the auto scaling group replace them
    Action items
    • Fix the Datadog integration for the nonproduction AWS account and repeat the installs with telemetry
    • Increase the worker root EBS volumes from 20GB to 120GB
    • Keep common base images pulled on every node with a DaemonSet until kops supports user hooks
    • Configure different allocation limits for the different layers in Kubernetes
    • Discuss a highly available Tiller with the Helm team
    • Find a way to throttle the number of newly created pods
    Lessons

    An ordinary deploy of the application could collapse the cluster, because the default 20GB gp2 root volumes could not keep up with parallel image pulls and container starts. Without node metrics and pod phase metrics, three NotReady workers raised no alert. A single Tiller replica can block the deploy that would fix an outage.

Check your cluster for this

These 20 cases involve Kubernetes API server and Application database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Dependency failure2 cases

  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0135 A power source switch during UPS maintenance cut power to a row of GPU servers and shut down Crusoe Cloud VMs in us-northcentral1

Configuration change1 case

Organisation
  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks

Breaking change in an upgrade2 cases

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours
  2. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

Capacity exhaustion7 cases

  1. IL-0080 kube-dns on Mercari's GKE clusters could not keep up with peak-hour DNS query rates, and a Sev1 production outage followed when several services failed DNS resolution
  2. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  3. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  4. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  5. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  6. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  7. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Software defect3 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  3. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Cloud provider outage2 cases

  1. IL-0145 A power sag and chiller failure in one Australia East availability zone took down the AKS control plane's compute and its non-zone-redundant SQL Database operation queue, blocking AKS create, update and delete operations in Australia East and Australia Southeast
  2. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022

Certificate or credential expiry1 case

Organisation
  1. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect

DNS or network fault1 case

Organisation
  1. IL-0199 A non-essential container exceeding its memory limit made GitHub's production pods unavailable, and their restarts failed because a DNS maintenance change had left the clusters unable to reach the image registry
    GitHub2020

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe