  1. Symptoms

    Services on the production Amazon EKS cluster behind the idus marketplace threw intermittent errors whose cause was hard to pin down. Calls to external services such as RDS and Redis failed now and then, and whenever DNS traffic spiked, domain lookups answered slowly or failed outright.

    Trigger

    All CoreDNS pods were scheduled onto the same node, and that node's memory usage spiked until it ran out of memory.

    Root cause
    Component
    Contributing factor
    Detection

    The write-up does not say how the full outage was noticed. The earlier DNS trouble showed up as intermittent service errors, and investigating failed calls to RDS and Redis led to DNS resolution failures.

    Remediation
    • deployed NodeLocal DNSCache as a DaemonSet in front of CoreDNS
    • added a PodDisruptionBudget (maxUnavailable 1) and topologySpreadConstraints across zones for CoreDNS
    • lowered ndots from 5 to 2 with dnsConfig in the Deployments
    Lessons

    The CoreDNS setup that EKS creates by default (two pods) can be enough for a small or development cluster but becomes a bottleneck in a large production cluster, and DNS is a single point of failure that needs high availability and room to scale. Tuning the CoreDNS cache and buffer size only relieved the symptoms; the real load came from the extra queries that ndots:5 generates for external names. A CoreDNS pod without a memory limit can share a node's fate with everything else on it.

  2. Symptoms

    Customers of DigitalOcean Managed Kubernetes (DOKS) saw worker nodes go NotReady between 06:00 and 07:00 UTC and stay unavailable, taking down the services on them, until the nodes were replaced or rebooted; some nodes needed several replacements or reboots. The first sporadic reports on October 8 said replacing the node fixed it. The same thing happened again around 06:00 UTC on October 9, more widely and across many regions, and again on October 10. Only clusters on versions 1.27.6-do.0 and 1.28.2-do.0 were affected.

    Trigger

    A systemd timer in the DigitalOcean Debian image started apt upgrade daily at 06:00 UTC, with a random delay of up to 60 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Sporadic customer reports of failed worker nodes arrived at 07:43 UTC on October 8; internal incident response started at 07:10 UTC on October 9 after broader impact across regions.

    Remediation
    • Advised customers to replace or reboot affected worker nodes
    • Arranged SSH and console access to worker nodes while they were healthy, and live-debugged an affected node on October 10
    • Released a DaemonSet to all affected clusters that disables the apt upgrade systemd timer on every worker node
    • Released new node images without the auto-update process
    Action items
    • Disable the timer during node provisioning, then remove the DaemonSet from all clusters
    • Add a check to the internal conformance test suite for new cluster versions that the auto-upgrade process and other unwanted timers stay disabled
    • Support logging into worker nodes even when normal access paths are broken
    Lessons

    An operating system auto-update timer left enabled in a node image can change the kernel and systemd underneath Kubernetes, and a timeout that kills the upgrade half-way can leave a node without networking. Failures that start at the same time every day point to a scheduled job on the nodes, and systemd timers belong on that list next to cron jobs. When the failure takes out a node's network, an investigation that depends on logging into the node stalls; access paths that work while the node is broken shorten diagnosis.

  3. Symptoms

    Builds on Zalando's in-house Continuous Delivery Platform (CDP), which runs CI/CD on Kubernetes, timed out and failed for almost an hour on 11 June 2019. The Kubernetes builder pods could not get AWS IAM credentials.

    Trigger

    An unlucky rescaling of the CDP Kubernetes cluster left only one node available for builder pods. Builder pods were created and deleted on that node so quickly that kubelet fell behind.

    Root cause
    Component
    Contributing factor
    Remediation
    • Scaled the CDP cluster up by hand so builder pods spread over more than one node
    Action items
    • Raise the kubelet QPS limit from the default 5 to 50 in the global cluster configuration
  4. Symptoms

    The NU.nl development team got reports that several services on one of its Kubernetes clusters behaved erratically: occasional error pages, slow responses and timeouts. The affected services were mostly internal tools and dashboards.

    Trigger

    A new ElastAlert rule, deployed shortly before from the command line, that fired if the Cloudfront-* Elasticsearch indexes stopped receiving documents; those indexes take a few million requests per hour, and the rule made ElastAlert's memory grow without bound.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported error pages, slow responses and timeouts from several services; no alert fired.

    Remediation
    • terminated the NotReady nodes one by one so the auto-scaling group replaced them (the new nodes also went NotReady, but Prometheus and Grafana landed on a stable node)
    • found the ElastAlert pods' memory growth on the Grafana pod memory dashboard
    • fixed the ElastAlert problem that caused the memory growth
    Action items
    • Define alerts on resource usage such as CPU, memory and disk space
    • Keep researching an alerting strategy that combines Elasticsearch, Prometheus Alertmanager and New Relic
    • Consider exporting metrics out of the cluster and running Grafana outside it, on EC2 or a separate Kubernetes cluster
    • Either visualise the important metrics in the ELK stack or make Prometheus and Grafana more available, and improve the metrics strategy
    • Set resource limits for ElastAlert through the Helm values
    • Configure namespaces with default memory requests and limits
    • Isolate customer-facing workloads from build, logging and monitoring workloads (a dedicated node group, or later a separate tools cluster)
    • Deploy everything through automation such as Jenkins pipelines, and consider a GitOps approach
    • Deploy through a pipeline that includes a smoke test step
    • Make Kubernetes and cloud infrastructure work part of the team's sprints, picked up by all team members while pairing with more experienced members, and hold workshops that go deep into specific topics
    Lessons

    Fixing the root cause covers only a small part of what an incident can teach; the chain of smaller failures around it is where most of the learning is. A pod without a memory limit can take whole nodes down, so limits need defaults at the namespace level. Monitoring that runs inside the cluster it watches goes blind with it. Changes installed by hand from the command line leave the rest of the team without a record of what changed.

  5. Symptoms

    The daily NRE Labs statistics showed lesson activity collapsing, and kubectl could not reach the cluster: `The connection to the server 1.2.3.4:6443 was refused - did you specify the right host or port?`

    Trigger

    Unknown. The liveness probe that kubeadm writes into the etcd static pod manifest (an `etcdctl get foo` against 127.0.0.1:2379, failureThreshold 8, timeoutSeconds 15) started failing. The author first suspected GCP maintenance the night before, but could not reproduce the probe failure by hand and does not know why it began.

    Root cause
    Component
    Contributing factor
    Detection

    The author saw lesson activity drop in the daily NRE Labs statistics during his morning routine.

    Remediation
    • removed the liveness probe section from the kubeadm-generated etcd static pod manifest and applied it between etcd restarts
    Action items
    • Add monitoring, especially for the single-node master
    • Run a basic "down for maintenance" page in Google Cloud Functions that points to Twitter for updates, to redirect to during outages
    Lessons

    Because all of the infrastructure is managed as code, the cluster could be rebuilt quickly, but destroying it before finding the cause also destroyed the evidence. Monitoring matters, especially with a single-node master. Read the restart counts in kubectl output, not just the Running status. Remember the fundamentals instead of expecting the issue to be more complicated than it is, and do not let the urgency of an outage push you into hasty decisions. Put up a maintenance page instead of leaving the site failing halfway.

Check your cluster for this

These 8 cases involve kubelet and Kubernetes API server. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Capacity exhaustion4 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  3. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  4. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Certificate or credential expiry1 case

Contributing factor
Organisation
  1. IL-0183 kubeadm's one-year leaf certificates expired, so kube-apiserver could not reach etcd, restarted in a loop and left the cluster unreachable

Configuration change2 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe