  1. Symptoms

    After further bug-fix deployments and reconnecting users on the launch day of the package sales ranking feature, a database alarm fired and the CPU of the Cookie Run: OvenBreak AWS Aurora MySQL database was at 100%. Database connections then failed, and players could not log in to or play the game.

    Trigger

    The package sales ranking feature was deployed, and further bug-fix deployments followed that reconnected users; each server update left more servers with empty caches that ran the ranking query against the database.

    Root cause
    Component
    Contributing factor
    Detection

    A database alarm fired, and the CPU graph of the Aurora MySQL database showed 100%.

    Remediation
    • Put the game servers into maintenance
    • Added a switch for the package sales ranking feature and turned the feature off, which restored the service
    • Rewrote the ranking query to group products that share a sale start time and to drop the current-time condition
    • Moved the ranking query to a scheduler server that runs it periodically and stores one shared cached result
    • Turned the package sales ranking feature back on after both fixes
    Lessons

    A heavy query combined with per-server caches in a distributed server setup caused a problem nobody expected, so the points likely to cause trouble need to be found in advance. During an outage, restoring the service comes before finding the cause, and a switch that turns a feature off, built in ahead of time, is a safety device that helps run a stable service. The online ALTER itself went well with Percona Toolkit and was used again for later schema changes.

  2. Symptoms

    Hours after a routine switch between two clusters of Retriever, Honeycomb's storage and query engine, late on 24 July 2023, the internal SLO for Shepherd, the ingest service, began to burn slowly. The performance was only marginally slow and inconsistent, with no good explanation, so engineers treated it as minor and left it for the morning.

    Trigger

    Late on 24 July Honeycomb switched between two Retriever clusters to avoid a subtle bug, and the new cluster stopped writing the last-written timestamps the schema cache depends on. On the morning of 25 July a feature flag flip meant to move those writes back stopped the remaining writes entirely.

    Root cause
    Component
    Contributing factor
    Detection

    Hours after the cluster switch, the internal SLO for the ingest service Shepherd started burning slowly. Engineers left it for the morning, when a chart showed that Retriever's database calls updating the last-written records had stopped.

    Remediation
    • Flipped only the writes back to the other Retriever cluster with a feature flag, which did not fix the problem
    • Set up circuit breakers that denied all Shepherd traffic with a 5xx error to protect the database
    • Failed the hard-locked database over to a replica
    • Restarted all Retriever hosts so they could provide data for the cache
    • Set the last-written timestamp of every schema with traffic in the last day to now, so the schema store reloaded the cache
    • Removed the circuit breaker and restarted the query hosts that failed internal checks
    Action items
    • Finish the Retriever cluster migration and remove all code that could disable writes behind the cache
    • Explore ways to strengthen the cache further
    • Lower the contention put on the database during update storms from new schemas
    • Stabilise the performance costs of some operations in the system
    • Study instrumentation and experimentation that detect and handle such edge cases better
    Lessons

    Locally good decisions combined into the outage: the query engine wrote the timestamps because it already saw all the data, the shared cache helped scale ingest and untangle the main database, the cluster switch was done to avoid a bug, frequent deploys hid the feature flag bug, pausing deploys during the investigation kept hosts from restarting, and past near-misses made the team expect a slow failover. Feature flags, frequent deploys, pausing deploys during incidents and learning from near-misses all contributed, although they are among the practices Honeycomb trusts most. For a rare lockup of this kind a database failover is the fastest recovery. Several recent Honeycomb incidents started from trying to avoid a subtle bug.

  3. Symptoms

    On 15 May 2019, alerts and customer reports showed that the Mezmo web application did not let users sign in, and the status page reported an indexing delay: incoming logs reached live tail and search late.

    Trigger

    A traffic spike that the tool tracking batches of logs was not sized to handle.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts and customer reports in the early morning hours triggered the escalation procedure and woke the on-call engineers.

    Remediation
    • Resized specific parts of the cluster to handle a much higher load
    Action items
    • Retool the batch tracking system to reduce its direct impact on the Redis clusters
    • Add observability instrumentation around the batch tracking feature set
    • Improve monitoring for Redis
    • Remove the bottlenecks in the pipeline that were involved in this incident
    Lessons

    Mezmo took from the incident that deep instrumentation, tracing and observability across the platform matter more as features scale up.

  4. Symptoms

    On Monday, September 10th, 2012, during a schema migration, the health checks on GitHub's MySQL master failed and Percona Replication Manager moved the 'active' role to another node of the new three-node cluster. That node's InnoDB buffer pool was cold and it performed poorly, its health checks failed in turn, and the role failed back to the original server. GitHub.com went down.

    Trigger

    A schema migration on Monday, September 10th put more load on the master database than earlier migrations had, and Percona Replication Manager's health checks on the master failed.

    Root cause
    Component
    Contributing factor
    Detection

    On the morning of September 11th, a developer told the operations team that the 'standby' node was returning incorrect query results.

    Remediation
    • Enabled Pacemaker's maintenance-mode so no health checks or automatic failovers ran, and let the buffer pool warm
    • Powered off the out-of-date node 'c' to end the partition
    • Stopped Pacemaker and Heartbeat on nodes 'a' and 'b' and started them on node 'a' only
    • Started MySQL on node 'a' in the active role
    • Removed the events leaked to wrong dashboards and audited the wrongly routed repositories
    • Contacted the owners of the exposed private repositories
    Action items
    • Change the Pacemaker configuration so the active database role fails over only when an operations engineer starts it
    • Find a way to warm the InnoDB buffer pool of slave databases so failovers do not hurt performance
    • Audit the Pacemaker and Heartbeat stack, focusing on the code path behind the segfault
    • Run hardware tests on the server where the segfault happened
    Lessons

    GitHub concluded that automated failover is not the right strategy for its primary production database: for every failover in this incident, any member of the operations team would have said it should not happen. Failovers that must happen, in an emergency or during maintenance, should not hurt performance.

Check your cluster for this

These 6 cases involve Database and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Dependency failure1 case

Organisation
  1. IL-0408 OpenRouter's API returned 500s and false 401 "User not found" errors when its API key cache dropped and came back empty

Capacity exhaustion2 cases

Organisation
  1. IL-0270 Discord's ScyllaDB authentication cluster overloaded during an OS upgrade, and logins failed for about 50 minutes
  2. IL-0297 Mezmo users could not sign in and log indexing lagged after the auth cache's Redis servers were OOM killed
    Mezmo2019

Faulty deployment1 case

Component
Organisation
  1. IL-0567 Aurora MySQL behind Cookie Run: OvenBreak hit 100% CPU after a sales-ranking feature launch, and players could not play

Software defect2 cases

Organisation
  1. IL-0217 Honeycomb's main MySQL database locked up under cache-miss reads and ran out of connections, a 68-minute total outage
  2. IL-0303 GitHub's MySQL master failed over to a node with a cold buffer pool during a schema migration and GitHub.com went down
    GitHub2012