Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases13 cases

3 to 7 of 13

  1. Symptoms

    During peak hours, when Mercari's GKE clusters handle very high request rates, the platform team saw kube-dns reaching its limits. DNS query rates were high enough to overwhelm the kube-dns service.

    Trigger

    Peak-hour traffic on the GKE clusters produced more DNS queries than the few kube-dns pods could answer.

    Root cause
    Component
    Contributing factor
    Detection

    During peak hours the team saw frequent NXDOMAIN and truncated-response errors and recurring "failed to refresh DNS cache" errors on the clusters, which showed that kube-dns had reached its limits.

    Remediation
    • deployed NodeLocal DNSCache on the Laboratory GKE cluster with a specific nodeAffinity to measure its effect
    • rolled NodeLocal DNSCache out gradually to the Dev and Prod environments by labelling node pools so its pods could be deployed there
    Lessons

    When every pod in a busy cluster resolves names through a few central kube-dns pods, DNS becomes a shared bottleneck, and a DNS failure quickly turns into higher latency, timeouts and cascading outages across microservices. A cache on each node takes most of that load off kube-dns and keeps resolution local to the node. Rolling the cache out first to an internal test cluster with nodeAffinity, and then node pool by node pool through labels, kept the blast radius of the change small.

  2. Symptoms

    At 13:42 UTC on 19 May 2025, RebelMouse's monitoring tools reported a higher error rate and degraded performance across services. A routine reroll of the EKS nodes had started 27 minutes earlier, at 13:15 UTC.

    Trigger

    At 13:15 UTC RebelMouse started its regular reroll of EKS nodes to apply security patches. The planned, automatic termination of an EC2 instance terminated one of the CoreDNS pods.

    Root cause
    Component
    Contributing factor
    Detection

    Monitoring tools detected an increased error rate and degraded service performance at 13:42 UTC, and the tech team started investigating at 13:44 UTC.

    Remediation
    • rescheduled the affected CoreDNS pod onto a new EC2 instance
    • scaled up the CoreDNS deployment to more replicas so DNS load was spread evenly across all pods
    Action items
    • Add scale-in protection so CoreDNS pods are not terminated unexpectedly during peak load
    • Review the CoreDNS configuration so that vertical scaling of the pods works
    • Hold regular capacity reviews so the CoreDNS deployment is provisioned for peak load
  3. Symptoms

    During a Lunar New Year event in January 2024, a developer posted a message in Slack suspecting an outage. While several people were checking it, the problem grew into a full outage of Backpackr's web and app services, and the company decided to stop the event.

    Trigger

    An unexpected traffic surge, more than three times normal, during the Lunar New Year event in January 2024.

    Root cause
    Component
    Contributing factor
    Detection

    A developer reported a suspected outage in Slack; the outage became total while several people were still confirming it.

    Remediation
    • stopped the Lunar New Year event
    Action items
    • Raise net.netfilter.nf_conntrack_max on all nodes to memory bytes/16384/2, and three times that on Istio nodes, applied by the nodeOptimizer DaemonSet
    • Configure Istio mesh networking so sidecars communicate directly instead of through the ingressGateway
    • Upgrade the Istio nodes from c6.xlarge (12.5 Gbps) to n-type instances with up to 25 Gbps of network bandwidth
    • Strengthen monitoring with ENA network bandwidth and packet drops, detailed Istio ingressGateway and sidecar metrics, and CPU, memory and saturation
    Lessons

    When every request in a cluster goes through one ingress gateway node, that node's connection tracking table and network bandwidth set the limit for the whole service. The default nf_conntrack table size was too small for three times normal traffic, and once it filled, packets were dropped. After the outage Backpackr strengthened its monitoring of network bandwidth, packet drops and the Istio components.

  4. Symptoms

    Services on the production Amazon EKS cluster behind the idus marketplace threw intermittent errors whose cause was hard to pin down. Calls to external services such as RDS and Redis failed now and then, and whenever DNS traffic spiked, domain lookups answered slowly or failed outright.

    Trigger

    All CoreDNS pods were scheduled onto the same node, and that node's memory usage spiked until it ran out of memory.

    Root cause
    Component
    Contributing factor
    Detection

    The write-up does not say how the full outage was noticed. The earlier DNS trouble showed up as intermittent service errors, and investigating failed calls to RDS and Redis led to DNS resolution failures.

    Remediation
    • deployed NodeLocal DNSCache as a DaemonSet in front of CoreDNS
    • added a PodDisruptionBudget (maxUnavailable 1) and topologySpreadConstraints across zones for CoreDNS
    • lowered ndots from 5 to 2 with dnsConfig in the Deployments
    Lessons

    The CoreDNS setup that EKS creates by default (two pods) can be enough for a small or development cluster but becomes a bottleneck in a large production cluster, and DNS is a single point of failure that needs high availability and room to scale. Tuning the CoreDNS cache and buffer size only relieved the symptoms; the real load came from the extra queries that ndots:5 generates for external names. A CoreDNS pod without a memory limit can share a node's fate with everything else on it.

  5. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

Check your cluster for this

These 13 cases involve Node pool and CoreDNS. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion13 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0067 Redis filled its persistent volume, corrupted its append-only file and crash-looped on every restart
  3. IL-0080 kube-dns on Mercari's GKE clusters could not keep up with peak-hour DNS query rates, and a Sev1 production outage followed when several services failed DNS resolution
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  8. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  11. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  12. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down
  13. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down