  1. Symptoms

    At 08:18 UTC on 13 July 2020, production Kubernetes pods began to be marked unavailable. The loss of pods spread through the clusters and reduced capacity until GitHub.com services went down.

    Trigger

    A container in the production pods exceeded its memory limit and was terminated; a routine DNS maintenance operation completed earlier had left the clusters unable to reach the image registry.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted the process with the cached DNS records so the clusters could reach the registry
    • fetched the container images, redeployed and recovered the services
    Action items
    • Improve monitoring so pod restarts cannot fail again in the same pattern
    • Minimise the dependency on the image registry
    • Expand validation during DNS changes
    • Re-evaluate all existing Kubernetes deployment policies
    • Improve progressive deployments so the impact of a deployment can be evaluated incrementally
    Lessons

    A container that production traffic does not need can still take pods out of service, because a pod is available only when all of its containers are healthy. ImagePullPolicy Always turns every container restart into a registry dependency, so an unrelated DNS change that breaks registry access turns a one-minute self-healing event into a long outage, and a mass redeploy spreads it.

  2. Symptoms

    Right after an updated RedisFailover resource was rolled out, the large Redis database lost all its data and the service went down; the data had to be restored from a backup taken just before the change.

    Trigger

    A RedisFailover change that raised the number of Redis replicas from one to two and, in the same rollout, lowered the containers' memory requests and limits from 22 GB to 19 GB.

    Root cause
    Component
    Contributing factor
    Remediation
    • restored the Redis data from the backup prepared before the rollout
    Action items
    • Report the readiness probe flaw to the Redis Operator project and test the developers' fix
    • Reconsider the use of the Spotahome Redis Operator
    • Clean up the Redis databases and fix the application code that created the excess keys
    • Consider Redis built-in clustering and sharding
    Lessons

    Changing the replica count and the pod resources in one rollout turned a seemingly harmless change into a rolling restart of the only pod with data while the new replica was still empty. A readiness probe that only checks that Redis answers a ping does not tell whether a replica has finished syncing. Operators for critical stateful components need to be evaluated for maturity before production use, and the dump.rdb file should be backed up before any change to the Redis cluster.

  3. Symptoms

    Builds on Zalando's in-house Continuous Delivery Platform (CDP), which runs CI/CD on Kubernetes, timed out and failed for almost an hour on 11 June 2019. The Kubernetes builder pods could not get AWS IAM credentials.

    Trigger

    An unlucky rescaling of the CDP Kubernetes cluster left only one node available for builder pods. Builder pods were created and deleted on that node so quickly that kubelet fell behind.

    Root cause
    Component
    Contributing factor
    Remediation
    • Scaled the CDP cluster up by hand so builder pods spread over more than one node
    Action items
    • Raise the kubelet QPS limit from the default 5 to 50 in the global cluster configuration
  4. Symptoms

    Users reported that their jobs were not starting, with some sign that image pulls were involved. Many pods across the cluster were in error states related to image pulls, while applications that were already running were not affected.

    Trigger

    A change to the permissions on a storage bucket that one application needed to read. The application could no longer start, and its DaemonSet, running on roughly a thousand nodes of the cluster, went into a crash loop with imagePullPolicy: Always, so every restart pulled the image again although it was already on the node.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that their jobs were not starting; monitoring had not caught it first.

    Remediation
    • replaced the affected NAT instances so registry traffic came from new source IPs
    • reconfigured the static IPs and firewall rules so applications could reach the Cloud SQL database again
    Action items
    • Add an admission webhook that rejects floating image tags, starting with latest
    • Apply the image tag webhook to workload objects only, not to pods, after it blocked pods created by in-cluster controllers
    Lessons

    The speakers' takeaway is to be very careful with DaemonSets in large clusters: they say they had broken everything DaemonSets depend on, including DNS, Vault and the image repository, and that it is very easy to break things when managing them by the thousand. imagePullPolicy: Always made every crash-loop restart pull the image again. Sending all registry traffic through three NAT instances put the whole region behind three source IPs, which the registry rate-limited, and changing those IPs cut the connections to a critical database reached over the internet through them. An admission webhook on pods rejects the pods that controllers in the cluster create, where no user sees the error.

  5. Symptoms

    Overnight into 26 March 2019 (PDT), every Prow test job that needed a GCP project from Boskos, the Kubernetes test-infra service that hands out GCP projects to test jobs, failed. The required job pull-kubernetes-e2e-gce failed on every run, so no pull request could be merged in kubernetes/kubernetes for just over nine hours, and other projects saw similar failures.

    Trigger

    At 23:04 PDT the node running the only Boskos pod was drained to be replaced with a 1.13 node during the upgrade of the Prow clusters from Kubernetes 1.11 to 1.13. The replacement pod started from the StatefulSet's current spec, which named a newer Boskos image containing the bug.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported the failure on GitHub at 02:50 and on Slack at 05:16 and 06:27, and an engineer saw the Slack reports on waking at 07:16. The Boskos monitoring dashboard showed the failure, but no alert caught it.

    Remediation
    • Built and deployed a new Boskos image with the bug fixed
    • Cleaned up the GCP projects that had been left open
    Action items
    • Change the Boskos configuration so that deployments actually take effect (#11956)
    • Automate Boskos deploys (#11957)
    • Improve alerting on Boskos status (#11953)
    Lessons

    The write-up lists what went poorly: a ten-hour upgrade was started shortly after 17:00 when on-call coverage ended at 18:00; deployments were not checked to confirm that something had actually rolled out; the Boskos StatefulSet was not set up to perform updates, so changing its spec left the old pod running; the December change appears never to have been tested; and Boskos was deployed by hand, unlike most of Prow, which left more room for error. Once people were available, the problem was fixed quickly.

Check your cluster for this

These 33 cases involve Kubernetes API server and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause11

Dependency failure3 cases

  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0489 Rejoining a failed node of Magic Pages' three-node MySQL cluster broke its metadata and took customer websites down
  3. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Cloud provider outage3 cases

  1. IL-0438 Builder Work became almost entirely unreachable with 504 errors when the Amazon CloudFront VPC Origins feature failed
    ANDPAD2026
  2. IL-0145 A power sag and chiller failure in one Australia East availability zone took down the AKS control plane's compute and its non-zone-redundant SQL Database operation queue, blocking AKS create, update and delete operations in Australia East and Australia Southeast
  3. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022

Capacity exhaustion13 cases

  1. IL-0465 IONOS Container Registry image pushes and pulls failed with 504 Gateway Timeout
  2. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  3. IL-0080 kube-dns on Mercari's GKE clusters could not keep up with peak-hour DNS query rates, and a Sev1 production outage followed when several services failed DNS resolution
  4. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  5. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  6. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  7. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  8. IL-0093 Ingress controller pods crash-looped one after another because the leader pod had exhausted its shared memory
  9. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  10. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  11. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  12. IL-0031 Kubernetes API server OOM-killed, leaving the Skipper ingress without routes; the talk points to a misconfigured CronJob manifest
  13. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Configuration change1 case

Organisation
  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks

Breaking change in an upgrade2 cases

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours
  2. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

Software defect3 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  3. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Hardware failure1 case

Contributing factor
Organisation
  1. IL-0185 A disk failure made the first control plane node of a Kubespray cluster read-only, and recovery needed the Kubespray inventory reordered and a new control plane node joined

Certificate or credential expiry2 cases

  1. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect
  2. IL-0460 Vault served an expired TLS certificate and almost every GoCardless service pod crash-looped, a 22-minute full outage

DNS or network fault2 cases

Organisation
  1. IL-0517 Gitpod workspaces failed to start worldwide and lost data when CoreDNS lookups to 8.8.8.8 timed out in its clusters
    Gitpod2022
  2. IL-0199 A non-essential container exceeding its memory limit made GitHub's production pods unavailable, and their restarts failed because a DNS maintenance change had left the clusters unable to reach the image registry
    GitHub2020

Faulty deployment2 cases

  1. IL-0088 A validating admission webhook added by a new ingress controller module version made the live-1 cluster reject every new Ingress with an x509 error
  2. IL-0467 Boskos crash-looped after a node drain started it from a buggy StatefulSet image, failing Kubernetes PR jobs for 9 hours

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe