  1. Symptoms

    On Sunday 25 October 2020 the GoCardless API, dashboard, payment pages and partner integrations were all unavailable for 22 minutes, from 07:32 to 07:54 GMT. Automated monitoring paged the on-call engineer at 07:32, a minute after every request to the API had started failing because no healthy backend was left.

    Trigger

    At 07:22 the TLS certificate Vault was still serving expired. cert-manager had already renewed it, but Vault does not load a new certificate without a restart or a SIGHUP.

    Root cause
    Component
    Contributing factor
    Detection

    Automated monitoring detected the failing requests and paged the on-call engineer at 07:32. Certificate expiry monitoring existed for the Layer-7 load balancers but did not cover the TCP load balancer that Vault uses.

    Remediation
    • Forced cert-manager to recreate the Vault certificate
    • Restarted the Vault cluster by hand so it loaded the new certificate
    • Deleted some pods of critical workloads to skip their 5-minute exponential backoff
    Action items
    • Check the certificate of the TCP load balancer in front of Vault with the Blackbox exporter, as for the Layer-7 load balancers
    • Deploy the Reloader controller to roll Vault when its certificate data changes
    • Change theatre-envconsul so envconsul no longer manages the child process and only injects secrets at container startup
    Lessons

    A system that almost every service depends on, such as the secrets store, can take everything down at once, and failure scenarios like Vault becoming unreachable had not been tested enough. Assuming the certificate had expired, when it had been renewed but not reloaded, added a slow and unnecessary recreation step to the recovery.

  2. Symptoms

    Services on Buffer's kops-managed cluster on AWS (about 60 nodes and 1500 containers) answered more slowly than they should have. The container throttling metric showed that many containers were being throttled whatever their CPU usage was, including containers that never came close to their CPU limit.

    Trigger

    CPU limits on user-facing services, enforced through CFS quota by a Linux kernel with a bug that throttled containers even when they were well under their limit.

    Root cause
    Component
    Contributing factor
    Detection

    While reviewing the container throttling metric, the team noticed many containers being throttled even though their CPU usage stayed far below their limits.

    Remediation
    • removed CPU limits from all services directly or indirectly on the users' critical path
    • moved those services to dedicated tainted nodes and gave them matching tolerations
    • set each service's CPU request to its peak usage over a few months plus a margin of more than 20%, and set memory requests the same way
    Action items
    • Move nodes to a kernel that contains the CFS throttling fix (4.19 or later), which for Buffer means a kops version whose host image is Ubuntu 20.04
    • After the kernel upgrade, check whether throttling is fully gone and update the post
    Lessons

    A CPU limit can slow a service down even when the service uses a small part of it, because of how the kernel enforces CFS quota on older kernels; the throttling metric shows it, the CPU usage graph does not. Upgrading the kernel is the safer fix. Removing limits works for latency, but only together with honest CPU and memory requests, isolation of the unbounded services, and monitoring of node usage, since unbounded containers can starve the kubelet.

  3. Symptoms

    On the Saturday the production cluster was moved from kops to EKS, the platform became very slow and too unstable to keep running, and the team reverted.

    Trigger

    Production was moved from a kops cluster using Weave networking to a new EKS cluster using the AWS VPC CNI, without external SNAT enabled.

    Root cause
    Component
    Contributing factor
    Detection

    The team lead saw the platform behaving very slowly after the switch to EKS and phoned the author.

    Remediation
    • reverted production to the kops cluster
    • set AWS_VPC_K8S_CNI_EXTERNALSNAT=true in the AWS VPC CNI
    Action items
    • Monitor and alert on the AWS VPC CNI
    Lessons

    In a networking problem every component in the stack is a suspect; ruling out EKS early cost a lot of time. A DaemonSet that pinged every component from every other one exposed the anomaly that led to the fix. The team had only skimmed the AWS CNI documentation before the migration; knowing how the plugin works internally would have led to better judgements and hypotheses while debugging.

  4. Symptoms

    Right after an updated RedisFailover resource was rolled out, the large Redis database lost all its data and the service went down; the data had to be restored from a backup taken just before the change.

    Trigger

    A RedisFailover change that raised the number of Redis replicas from one to two and, in the same rollout, lowered the containers' memory requests and limits from 22 GB to 19 GB.

    Root cause
    Component
    Contributing factor
    Remediation
    • restored the Redis data from the backup prepared before the rollout
    Action items
    • Report the readiness probe flaw to the Redis Operator project and test the developers' fix
    • Reconsider the use of the Spotahome Redis Operator
    • Clean up the Redis databases and fix the application code that created the excess keys
    • Consider Redis built-in clustering and sharding
    Lessons

    Changing the replica count and the pod resources in one rollout turned a seemingly harmless change into a rolling restart of the only pod with data while the new replica was still empty. A readiness probe that only checks that Redis answers a ping does not tell whether a replica has finished syncing. Operators for critical stateful components need to be evaluated for maturity before production use, and the dump.rdb file should be backed up before any change to the Redis cluster.

  5. Symptoms

    An alert fired because some Metrictank instances could not drain their write queue, which meant they could not write to Cassandra. Google had not yet published an incident, but a team member's Discord server, also hosted on GCP, was down, which pointed at GCP; Google confirmed an SSD persistent disk incident about 90 minutes after it began.

    Trigger

    A Google Cloud incident in which SSD persistent disks performed so poorly that many I/O operations failed for an extended period.

    Root cause
    Component
    Contributing factor
    Detection

    An alert that Metrictank write instances could not flush their write queue to Cassandra. Error rates alone rose too slowly to notice quickly, because most queries were served from memory.

    Remediation
    • Added compute nodes hoping new nodes could attach the disks, which did not work
    • Deleted and recreated the Cassandra StatefulSet with an updated pod management policy, so all pods but one started
    • Raised Kafka topic retention to avoid data loss during the long downtime
    • Temporarily added nodes so Metrictank restarts were not slowed by CPU starvation
    • Restarted all Metrictank instances, which took more than 20 hours, so they connected to the new Cassandra IPs
    Action items
    • Re-instantiate the gocql connection in Metrictank when it is detected dead, so it reconnects even when all Cassandra IPs change
    • Fix the Metrictank write-queue deadlock by updating an internal data structure with atomics instead of a lock
    Lessons

    An OrderedReady StatefulSet cannot recover past a single pod whose volume will not attach; when every pod is down, the ordering that protects normal start-up blocks the whole cluster. A client that learns peer addresses only from live peers needs a way to go back to the service name when all peers are replaced at once. A long-tolerated bug with a config workaround can surface at the worst time; this one turned out to have a simple fix. Writing incoming data to a Kafka write-ahead log first meant all data could still be ingested after recovery, and Kafka on non-SSD disks escaped the disk incident. With both Metrictank bugs fixed, the team expects a similar event to take less than 3 hours to recover from instead of 23.

Check your cluster for this

These 43 cases involve Ingress controller and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Configuration change12 cases

  1. IL-0179 With DEBUG logging and synchronous log output, a high-traffic service filled the 64 KB stdout pipe, so request threads blocked in write() while holding database connections and HikariCP ran dry, failing requests in 30-second bursts
  2. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  3. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  4. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  5. IL-0231 Deleting EKS managed node groups also deleted Karpenter's instance profile, and every Stytch worker node shut down
    Stytch2023
  6. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
  7. IL-0442 Older pods on LIFULL's KEEL Kubernetes cluster were preempted all at once and the external error rate spiked
    LIFULL2021
  8. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  9. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  10. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  11. IL-0061 A Terraform pull request merged out of order deleted a production GKE cluster, and recreating it deleted a second one
  12. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files

Capacity exhaustion8 cases

  1. IL-0470 Buildkite notifications were delayed after Prometheus storage filled and EKS notification workers could not autoscale
  2. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  3. IL-0433 Shifting API traffic from EC2 to EKS on Fargate overloaded two CoreDNS pods and caused mass name-resolution errors
  4. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  5. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  6. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  7. IL-0518 gitlab.freedesktop.org on GKE ran short of volume space and a planned 30-minute storage upgrade became a 4-hour outage
  8. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Breaking change in an upgrade2 cases

  1. IL-0097 A cluster autoscaler version bump was incompatible with the one cluster still on Kubernetes 1.33, so no scale-up events fired and new nodes were not created
    2i2c2026
  2. IL-0522 An ingress-nginx chart upgrade deleted the jenkins.io Ingress and Fastly served HTTP/503 errors for hours

Faulty deployment5 cases

  1. IL-0160 A repaired legacy GPU monitoring script sent a firmware query that triggers a race condition in the GPU System Processor of NVIDIA RTX 4000 Ada GPUs, locking up GPU Linodes and LKE worker nodes in several regions
    Linode2026
  2. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  3. IL-0324 Three MediaWiki deployments lost Memcached after a PHP 8.1 rollout and overloaded the External Storage database cluster
  4. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019
  5. IL-0467 Boskos crash-looped after a node drain started it from a buggy StatefulSet image, failing Kubernetes PR jobs for 9 hours

DNS or network fault2 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node

unknown1 case

Organisation
  1. IL-0087 After a cold reboot of RKE2 nodes, pods could not get IP addresses because Multus could not reach the Kubernetes API, and further reboots spread the failure to every node

Operator error2 cases

Organisation
  1. IL-0197 Moving a three-node Elasticsearch StatefulSet to new persistent volumes split the cluster in two, because the Helm chart hardcoded cluster.initial_master_nodes to elasticsearch-0
    Palark2021
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage

Certificate or credential expiry1 case

Organisation
  1. IL-0460 Vault served an expired TLS certificate and almost every GoCardless service pod crash-looped, a 22-minute full outage