  1. Symptoms

    About a minute after the etcd leader changed, two replicas of the Cortex distributor started logging "context deadline exceeded" when they tried to read keys from etcd. Writes from some customers that landed on those two replicas failed, while the other distributor replicas kept working, so the service saw an error rate of about 20% on writes to the London region of Hosted Prometheus.

    Trigger

    A scheduled Kubernetes version upgrade abruptly terminated the node that ran the etcd leader at 11:19:00 UTC.

    Root cause
    Component
    Contributing factor
    Detection

    An SLO-based alert paged the on-call engineer at 11:31, 11 minutes after the errors started. At a 20% error rate the monthly SLA would have taken about 18 hours to breach.

    Remediation
    • Restarted the two affected Cortex distributor replicas at 11:32, which stopped the errors
    Action items
    • Enable gRPC keepalive probes in the Cortex etcd client (DialKeepAliveTime 10s, DialKeepAliveTimeout, PermitWithoutStream)
    • Make the Kubernetes upgrade process terminate pods and machines gracefully, including the etcd pods managed by the etcd operator
    Lessons

    When a node dies abruptly, clients holding TCP connections to it are not told; without keepalive probes an etcd client can keep sending requests into a dead connection long after a new leader exists. A failover that works on the server side still needs clients that detect the dead peer. Node replacement during cluster upgrades should drain pods gracefully, including pods owned by operators that the upgrade scripts do not know about, and should give instances enough time to shut down.

  2. Symptoms

    Shortly after a round of changes, loveholidays saw connectivity problems and raised error rates on its aggregation service. The service is a proxy between two other services of more than 100 instances each, handles over 10,000 requests per second continuously and can spike to four times that.

    Trigger

    Three changes together: a change in service architecture, halving the RAM of the nodes that run the aggregation service, and sharding a downstream service, which doubled the number of connections to track.

    Root cause
    Component
    Contributing factor
    Detection

    Rising error rates and climbing connection reset errors in HAProxy, then node_exporter conntrack metrics compared with their limit.

    Remediation
    • moved the aggregation service to nodes with more RAM
    • limited the number of aggregation service pods per node
    Action items
    • Alert when conntrack table use goes above 75%, with (node_nf_conntrack_entries / on (pod) node_nf_conntrack_entries_limit / on (pod) group_right kube_pod_info) > 0.75
    Lessons

    The conntrack limit is tied to node memory, so resizing a node pool silently resizes the connection table, and on GKE the ratio did not match the commonly cited formula. A high-traffic proxy on small nodes can exhaust it, and the symptoms are connection resets and timeouts, so conntrack use needs its own metric and alert.

  3. Symptoms

    A colleague wrote in Slack that his application was taking a long time to deploy. A deployment that normally finishes in minutes had been running for about an hour: about half of the new pods were running and serving traffic, and the other half were Pending.

    Trigger

    The cluster reaching 256 nodes, the most its /16 pod secondary range could hold at 256 addresses per node; every further node creation failed.

    Root cause
    Component
    Contributing factor
    Detection

    A colleague reported in Slack that a deployment was slow; the pending pods' events and the cluster autoscaler status ConfigMap showed the exhausted IP space.

    Remediation
    • lowered the maximum pods per node on selected node pools, cutting IP consumption by about 30%
    • moved some node pools to larger instance types
    Action items
    • Lower the maximum pods per node on node pools that do not run many pods
    • Use larger instance types in some node pools
    Lessons

    In a VPC-native GKE cluster the number of nodes, not the number of pods, uses up the pod range: by default each node reserves 256 addresses, so even a /16 is full at 256 nodes. Maximum pods per node and node size are the practical levers; larger nodes pack better but take more pods down when they fail.

  4. Symptoms

    From 07:20 UTC on 28 September 2019, customers running Azure Kubernetes Service clusters on Virtual Machine Scale Sets (VMSS) got failures when they tried any cluster upgrade. The error read: "The platform image 'microsoft-aks:aks:aks-ubuntu-1604-201909:2019.08.21' is not available. Verify that all fields in the storage profile are correct." The issue title calls the error PlatformImageNotFound.

    Trigger

    A recent service update affected instances of a backend service, which became unhealthy and stopped requests from completing.

    Root cause
    Component
    Contributing factor
    –
    Detection

    Customers received failure messages when they tried to upgrade their clusters.

    Remediation
    • published az vmss update commands that set the scale set's image version to 2019.09.25 and SKU to aks-ubuntu-1604-201909, after which the upgrade could be run again
    • mitigated affected clusters by hand (AKS and VMSS teams)
    • rolled out hot fixes to all regions, completed by 15 October 2019
  5. Symptoms

    At 16:00 CEST a developer reported in the #ask-platform Slack channel that a deployment to the Prelive cluster was failing, and a second report followed at 16:06.

    Trigger

    Roughly two to three days earlier, the CentOS repository mirror was restructured and container-selinux-2.68-1.el7.noarch.rpm moved, which made the static download URL hardcoded in kops nodeup invalid.

    Root cause
    Component
    Contributing factor
    Detection

    Developers asked for help in the #ask-platform Slack channel because their deployments were failing.

    Remediation
    • downloaded the package by hand on the Prelive nodes so their bootstrap could finish
    • changed the cluster AMI from Amazon Linux 2 to Debian and applied it to all clusters
    Action items
    • Create an alert that shows when nodes cannot join the cluster, possibly from information the cluster autoscaler already has
    • Document the external dependencies of node startup and look for ways to reduce them
    • Change the AMI back to Amazon Linux 2 Minimal once kops fixes the issue
    • Document node troubleshooting better: what happens during bootstrap and where the logs are
    Lessons

    Applying cluster changes through kops and Jenkins worked well, and troubleshooting quickly showed that the failing deployments came from missing cluster capacity. What went wrong was that nobody noticed, over a long period, that some autoscaling groups held more worker instances than Kubernetes had nodes. The team was lucky that no large number of production spot instances was terminated during the problem and that it was noticed during office hours.

Check your cluster for this

These 36 cases involve Node pool and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing

Faulty deployment5 cases

  1. IL-0166 A compute host update removed the credential parser used to decode StackScripts, so new Linodes and every new LKE and LKE-E node failed to boot and autoscaling and node recycling failed in all regions
    Linode2026
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down
  3. IL-0163 An API change that slipped through a gap in automated testing made LKE clusters resize to the wrong number of nodes and added billable worker nodes to customer accounts
    Linode2023
  4. IL-0164 An incremental Linode Kubernetes Engine production update that was missing changes from the previous release made cluster upgrades and node additions fail silently
    Linode2022
  5. IL-0149 Upgrades of AKS clusters on Virtual Machine Scale Sets failed with a 'platform image is not available' error after a service update left a backend service unhealthy

Certificate or credential expiry2 cases

  1. IL-0158 An expired credential caused authentication failures that stopped LKE and LKE-E from deploying clusters and nodes in all regions, which also blocked node recycling and cluster autoscaling
    Linode2026
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect

Breaking change in an upgrade1 case

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours

Software defect4 cases

  1. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  2. IL-0078 Enabling EKS secrets encryption with KMS through Terraform removed worker node IAM permissions and took down all ZenML Pro workspaces
    ZenML2025
  3. IL-0161 A faulty earlier API update made new LKE cluster provisioning in Toronto time out for three days, leaving clusters with no node pools or the wrong number of nodes
    Linode2024
  4. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes

Configuration change6 cases

  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours
  2. IL-0019 An EKS Terraform module upgrade shrank node root disks from 100 GB to 20 GB and image pulls failed with no space left on device
  3. IL-0017 AWS VPC CNI stopped allocating pod IP addresses on six nodes of the live cluster, leaving new pods in ContainerCreating
  4. IL-0091 Changing the worker node instance type through Terraform recycled all nodes at once and deleted users' production pods together
  5. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  6. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Operator error2 cases

  1. IL-0018 A Docker Hub password rotation left EKS nodes and Concourse locked out of Docker Hub and unable to pull images
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage3 cases

  1. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021
  3. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA