Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases7 cases

4 to 7 of 7

  1. Symptoms

    Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.

    Trigger

    An abnormally large number of queries arrived from many separate connections within a few minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.

    Remediation
    • Scaled the ingest fleet up manually and aggressively
    • Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
    • Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
    Action items
    • Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
    • Decide on the projects that will address these failure paths
    Lessons

    Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.

  2. Symptoms

    From 03:03 US/Pacific on 14 June 2022, calls to the GKE API in us-central1 through gcloud and the Google Cloud Console were slow and returned errors. Retrying sometimes succeeded.

    Trigger

    An unexpected increase in backend traffic to the GKE API in us-central1.

    Root cause
    Component
    Contributing factor
    Remediation
    • scaled up the GKE control plane to handle the increased traffic
    Lessons

    Client retries against an overloaded management API add to the overload. When the cloud provider's control plane is degraded, running workloads may be fine while cluster operations fail, and the status page offered no workaround beyond advising customers to use another region if they could.

  3. Symptoms

    On Friday 19 July 2019 the Grafana Cloud Hosted Prometheus service, which is built on the Cortex project, was down for 26 minutes. New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start.

    Trigger

    An engineer created a new dedicated Cortex cluster for a large customer. Its configuration did not include the new pod priorities, so all its pods got the default medium priority, and the Kubernetes cluster did not have enough free resources to fit it.

    Root cause
    Component
    Contributing factor
    Detection

    New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start of the outage.

    Remediation
    • Scaled up the underlying Kubernetes cluster to fit both the new and the production Cortex clusters
    • Diagnosed and fixed the out-of-memory errors in the authenticating reverse proxies in front of Cortex
    Action items
    • Give the production ingesters the high priority class, which should have been done before medium became the default
    • Have more people review changes to configuration that is global to the cluster
    • Require a design document for every configuration change outside a namespace
    • Automate the sizing of the frontend authenticating reverse proxy so it does not run out of memory under overload
    • Investigate the default backoff and scaling behaviour of Prometheus to prevent a stampeding herd of retries
    Lessons

    Medium should not have become the default priority until the production ingesters had the high priority, and that designation should have reached production sooner. The change was considered too minor for a design document and was only discussed in a GitHub issue; cluster-global configuration needs more scrutiny. On the positive side, once Cortex had enough capacity it recovered by itself, and Grafana Loki helped confirm that the ingesters exited gracefully.

  4. Symptoms

    Customers of the Zalando Fashion Store got a high rate of errors on all web product pages and outfit pages for more than an hour. The errors came from the main data aggregation layer service, which runs in one of Zalando's Kubernetes clusters.

    Trigger

    Calls from the aggregation layer to a single, not very important downstream service started timing out. The aggregation layer returned 404s for them, clients retried, and the resulting spike in requests became a spike in DNS queries to CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The on-call engineer for the aggregation layer phoned the on-call Kubernetes engineer. Automatic paging did not happen because the cluster's monitoring and alerting ran inside the cluster and failed along with DNS. The Kubernetes engineer then saw that the CoreDNS pods were being OOM-killed.

    Remediation
    • Raised the CoreDNS memory requests and limits by hand from 100Mi to 2000Mi
    Action items
    • Introduce a more resilient DNS setup: CoreDNS fronted by dnsmasq on every node
    • Improve high-level alerting from outside the clusters, so that a cluster problem is known before or at the same time as applications are affected
    • Improve incident response processes and tooling so that any on-call engineer can escalate directly to other teams when automatic paging fails, for example through a chat bot
    Lessons

    The Kubernetes DNS setup was far from resilient enough: a single application could take down DNS for everything in the cluster. The blast radius of one application sending more DNS queries should be limited to one node at most, ideally to single pods. Known Kubernetes DNS problems, such as Linux kernel races in conntrack handling and the ndots 5 problem, were familiar to the team and partly mitigated, but their combined effect on the DNS infrastructure was worse than the team had understood. Monitoring that runs inside the cluster was not robust enough: when the cluster's DNS broke, it could not page anyone, and recovery took longer than it should have.

Check your cluster for this

These 7 cases involve Application database and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Faulty deployment1 case

Organisation
  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours

Capacity exhaustion4 cases

  1. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  2. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  3. IL-0140 The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worse
  4. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries

Software defect1 case

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1

Configuration change1 case

Organisation
  1. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down