  1. Symptoms

    ByteDance's large language model training jobs on its MegaScale system, which runs on more than 10,000 GPUs, occasionally stalled or slowed down. The cause was network interfaces that flapped frequently.

    Trigger

    Network interfaces went down for several seconds and came back up, dropping every packet in transit.

    Root cause
    Component
    Contributing factor
    Detection

    MegaScale's monitoring system uses second-level monitoring to track link flapping and other NIC issues. When the RDMA traffic metrics carried in the training daemons' heartbeats drop sharply or fluctuate abnormally, the driver raises an alert for manual investigation, and if the traffic stops entirely it starts the fault recovery procedure automatically.

    Remediation
    • set NCCL's timeout threshold explicitly to a larger value than the default
    • tuned NCCL's retransmit timer and retry count for fast recovery under link flapping
    • enabled the adap_retrans feature on the NICs
    • applied lower-level quality control to NIC signal strength, AOC cable quality and switch-side signal strength
    Lessons

    A default NCCL timeout can be shorter than the few seconds an interface needs to come back from a flap, so a brief link loss becomes a failed collective and a stalled job. A larger timeout and faster retransmission give the link time to return, but the flapping itself came from physical link quality between NIC, AOC cable and switch, and quality control at that level reduced it.

  2. Symptoms

    Between 06:00 and 07:00 UTC on 8 March 2023, Kubernetes nodes in several Datadog regions lost network connectivity at the same time, on AWS, Google Cloud and Azure. All services across multiple regions were affected, including the regions that host Datadog's CI/CD and automation tools. Datadog's regions are not connected to each other and changes are rolled out one region at a time, so a simultaneous failure on several cloud providers looked implausible at first.

    Trigger

    On 7 March 2023 Ubuntu published a systemd patch for a CVE (249.11-0ubuntu3.7). Ubuntu's default unattended upgrades installed it on the nodes between 06:00 and 07:00 UTC on 8 March, and installing it restarted systemd-networkd.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted thousands of disconnected instances on Google Cloud and Azure through the cloud APIs, keeping their local disks
    • rebuilt the data lost with terminated AWS instances' local disks through replication, reprocessing and restores from backup
    Lessons

    A change in a base operating system component can stay dormant for months until something restarts that component. Here the trigger was a security patch, and the change reached every region at once because automatic OS updates ran outside the progressive, region-by-region process used for every other change. Cloud providers react differently to an instance that loses its network. Google Cloud and Azure left the instances running, so a restart recovered them with their disks; AWS replaced them quickly, which brought stateless services back fast but destroyed the local-disk data the stateful services needed.

  3. Symptoms

    At 4:53 pm Pacific on 25 January 2023 one of OpenAI's GPU clusters had a major outage, and the text-davinci-003 model went fully down.

    Trigger

    A configuration change to the CNI (Container Network Interface) plugins, which provide network connectivity to containers, was deployed to a GPU cluster that contained a hardware variant the staging environment did not have.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers immediately identified the problem as network connectivity, but it took nearly an hour to identify CNI as the cause.

    Remediation
    • put a fix for the CNI configuration change in place, which restored 80% of traffic immediately
    • deployed models back onto GPUs over about three more hours until capacity was fully stable
    Action items
    • Make staging environments contain every type of hardware configuration so they better represent production
    • Monitor and alert on the health of the CNI system directly
    • Fix the network and storage bottlenecks that limit how quickly many replicas of a model can be deployed
    Lessons

    A change that had been deployed to other clusters over 24 hours and deemed safe still broke a cluster with different hardware, so staging needs every hardware configuration that production has.

  4. Symptoms

    A production service at Airbnb showed a high error rate and could not be deployed. The deploy failed with a cryptic Kubernetes error about being unable to access invalid index 5.

    Trigger

    A change to the mutating admission controller, which had been rolled out within the previous month, had gone in seven days before the incident surfaced; when it had to delete two items from an array in a spec, it generated an invalid JSON patch that removed index 2 and then index 3.

    Root cause
    Component
    Contributing factor
    Detection

    The affected service reported a high error rate and its deploy failed; the slow degradation of other services over the previous seven days had gone unnoticed.

    Remediation
    • deleted the mutating admission controller from the affected cluster
    Action items
    • Create alerts from the existing metrics that would have shown the problem earlier
    Lessons

    Keep in mind that a mutating admission controller exists in the cluster; a recently added one is easy to forget during an incident. Search for the exact error message early instead of working on the visible symptoms. Page a teammate when progress stalls.

Check your cluster for this

These 7 cases involve NCCL and Shared network filesystem. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Capacity exhaustion2 cases

  1. IL-0137 Training initialisation on a 60-node NVIDIA B200 cluster took more than 8 hours instead of minutes because fragmented small random I/O from all nodes saturated the metadata service of the VAST Data NFS storage
  2. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count

Dependency failure1 case

Organisation
  1. IL-0025 Failed boots, InfiniBand link flapping, NCCL hangs and throughput sags while bringing up a 4,088-GPU H100 training cluster
    Imbue2024

DNS or network fault1 case

Contributing factor
Organisation
  1. IL-0128 Network interfaces that dropped for a few seconds made NCCL time out and stalled or slowed LLM training on a cluster of more than 10,000 GPUs

Breaking change in an upgrade1 case

Organisation
  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Configuration change1 case

Component
Organisation
  1. IL-0116 A CNI configuration change incompatible with a hardware variant that exists only in production cut network connectivity in an OpenAI GPU cluster and took text-davinci-003 fully down
    OpenAI2023

Software defect1 case

Organisation
  1. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods
    Airbnb2020