Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases45 cases

36 to 40 of 45

  1. Symptoms

    Some nodes in Google Kubernetes Engine clusters that had recently been upgraded showed an elevated number of kernel panics. The status page described it as kernel panics following an upgrade in GKE version.

    Trigger

    Upgrading GKE node pools to one of the affected 1.13 or 1.14 versions.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • advised affected users to downgrade to a patch release not on the affected list, with support helping Release Channel users
    • released GKE 1.13.11-gke.14, 1.13.12-gke.8, 1.14.7-gke.23 and 1.14.8-gke.12, which downgraded Container-Optimized OS to cos-73-11647-293-0
    • rolled the fixed versions out to node pools with auto-upgrade enabled; clusters on manual upgrades had to upgrade their nodes themselves
    Action items
    • Ship a GKE release with an upgraded kernel that fixes the panics
    Lessons

    Downgrading the node operating system image was used as a temporary mitigation until a kernel fix was available.

  2. Symptoms

    After Ravelin moved its API layer from VMs into its GKE cluster behind a Kubernetes Ingress, the integration tests occasionally received 502 errors.

    Trigger

    Pods behind the Ingress being removed by their controller, as happens during rolling deploys and scaling.

    Root cause
    Component
    Contributing factor
    Detection

    Integration tests occasionally received 502 errors.

    Lessons

    Removing a pod's endpoint and signalling the pod happen at the same time, and an ingress can take a long time to catch up. A pod behind an ingress should keep serving after SIGTERM until its grace period ends, and the grace period should be longer than the load balancer's reprogramming time.

  3. Symptoms

    On a Sunday, a team using one of Skyscanner's Kubernetes clusters manually paged the out-of-hours Kubernetes support because their service showed elevated latency, worst at the p90 and maximum levels.

    Trigger

    Upgrading the HAProxy ingress controller to v0.6 and going back from Service virtual IPs to individual pod IPs as backends, on the understanding that the sort-backends flag introduced in v0.5, false by default, meant backends were randomly shuffled.

    Root cause
    Component
    Contributing factor
    Detection

    A cluster user manually paged the out-of-hours Kubernetes support about elevated latency; Prometheus queries then showed the uneven request distribution across pods.

    Remediation
    • switched the affected service from pod IPs back to the Service virtual IP through a config change in the internal deployment tool Slingshot
    • patched the controller to keep each backend's servers in an insertion-ordered slice and changed the template to iterate over that slice
    • tested the patch in sandbox clusters and rolled it out to the production clusters
    Action items
    • Run the internal controller patch in production and return to pod IPs as the default backends
    • Raise the problem upstream with a GitHub issue and pull request
    • Test changes to cluster components against the specific behaviour and conditions that matter
    Lessons

    The team already knew that sorted backends cause hot-podding and still did not test the new flag well enough to see that it did not work; changes to cluster components need tests aimed at the exact behaviour that matters, under conditions like production. A keyword can behave differently in different parts of a language: range over a map is unordered in Go code but sorted in text/template. A small cluster component can do outsized harm to every user of the cluster and, in the end, to customers.

  4. Symptoms

    Fewer than 20% of the nodes in one Zalando cluster were available. Most nodes reported NotReady at the same moment, and only a handful stayed Ready.

    Root cause
    Component
    Contributing factor
    Remediation
    • none; the nodes recovered on their own after about 15 minutes
  5. Symptoms

    Services that used the team's Redis-dependent library crashed on start-up, and their teams reported it to the ops members. The Spring Boot logs showed the applications failing to resolve the Redis hostname during bean initialisation.

    Root cause
    Component
    Contributing factor
    Detection

    Service teams reported start-up crashes to the ops members of the team; later the resolution failures were seen in Kibana.

    Remediation
    • set ndots to 4 with a dnsConfig block in the Kubernetes deployment manifests
    • corrected the maximum connection pool size in the Redis library, cutting Redis connections by about 70%
    Action items
    • Test Debian glibc-based base images added to the image library to see whether they resolve the DNS problems
    • Update dependencies to newer Netty versions
    Lessons

    With ndots:5, a name outside the cluster that has fewer than five dots is first tried with every cluster search domain. Adding a trailing dot avoids that, but only if every library in the path accepts it, and the Netty version in use did not. The ndots change is a workaround that will not hold forever. The author would like better alerting for this kind of failure but notes that alerts on one-off DNS failures are not wanted.

Check your cluster for this

These 45 cases involve Ingress controller and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Software defect45 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  3. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  4. IL-0104 After a CoreDNS pod was OOMKilled, the talk names three causes: Istio's aggressive DNS cache refresh on one reused client port, kube-proxy not cleaning up conntrack entries of terminated pods, and the 2-minute UDP conntrack timeout
  5. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  6. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  7. IL-0022 Three overlapping infrastructure bugs (context-window misrouting, TPU output corruption and an XLA top-k miscompilation) degraded Claude's responses
  8. IL-0078 Enabling EKS secrets encryption with KMS through Terraform removed worker node IAM permissions and took down all ZenML Pro workspaces
    ZenML2025
  9. IL-0053 Unauthenticated ingress-nginx admission webhook let anyone on the pod network run code and read every Secret in the cluster (IngressNightmare, CVE-2025-1974)
    Wiz2025
  10. IL-0081 API requests timed out during deployment rollouts because the ingress-nginx enable-serial-reloads option held back endpoint updates while a long NGINX reload was running
    Cresta2025
  11. IL-0157 After a release, new nodes could not join Linode Kubernetes Engine clusters with IP ACL enabled, so autoscaling failed on about 20 to 25 clusters
    Linode2025
  12. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  13. IL-0148 A kube-scheduler regression in Kubernetes v1.27.14, v1.28.10 and v1.29.5 made the scheduler panic on a pod whose node affinity named a nonexistent node, so no pods were scheduled on affected AKS clusters
  14. IL-0131 A new kind of GenerateContent request made Vertex AI prediction API servers segfault, and once enough of them restarted at the same time the serving fleet could not carry the load
  15. IL-0077 EKS cluster went read-only for over seven hours after Kyverno ephemeralreports filled the etcd database past its size limit
  16. IL-0024 Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three times
  17. IL-0161 A faulty earlier API update made new LKE cluster provisioning in Toronto time out for three days, leaving clusters with no node pools or the wrong number of nodes
    Linode2024
  18. IL-0173 cert-manager's preferredChain logic picked the Let's Encrypt chain through the expired DST Root CA X3, so clients built on an old BoringSSL could not connect to a development server
  19. IL-0065 Any pod could take over the cluster by rewriting Argo CD's unauthenticated Redis cache (CVE-2024-31989)
    Cycode2024
  20. IL-0123 A response buffer allocated anew in a loop made OpenAI's routing layer nodes hit their memory limits and fail readiness checks on a morning with more completions than any day before, causing 502 and 503 errors across all models
    OpenAI2023
  21. IL-0141 gke-metadata-server versions 0.4.272 to 0.4.280 flooded Cloud Logging with "Unable to sync sandbox" debug logs on GKE clusters with Workload Identity, using up logging quota and adding billable usage
  22. IL-0151 A latent defect in the AWS Lambda Frontend, set off when one us-east-1 cell scaled past a size never reached before, raised errors for Lambda and for services that depend on it, including new EKS cluster provisioning
  23. IL-0174 After an upgrade to Fluent Bit 2.0, logging sidecars that used the Kafka output plugin kept restarting with SIGSEGV because the plugin read a corrupted record as a map without checking its type
  24. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  25. IL-0139 Pods on GKE clusters with Calico network policy got stuck Terminating or Pending after upgrading to 1.22 or later because of a race condition in the Calico component
  26. IL-0175 Lowering a JVM pod's CPU request from 2 to 1 pushed memory past the 90% alert because the JVM treats a cgroup v1 cpu.shares value of exactly 1024 as unset and sized Reactor Netty threads from the node's 36 CPUs
  27. IL-0132 A faulty resource cleanup process marked Vertex AI prediction endpoints as deleted worldwide, undeploying customers' models and failing predictions for 4 hours 20 minutes
  28. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021
  29. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods
    Airbnb2020
  30. IL-0146 New AKS clusters with Azure CNI in Central India lost tunnel connectivity because VMs began getting MAC addresses with a 06 prefix, which exposed a dormant bug in bridge-mode Azure CNI
  31. IL-0041 fluent-bit silently stopped shipping application logs from one node to Elasticsearch
  32. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  33. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes
  34. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  35. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  36. IL-0143 GKE nodes upgraded to certain 1.13 and 1.14 versions had an elevated number of kernel panics, fixed by releases that downgraded the Container-Optimized OS image
  37. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  38. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  39. IL-0030 Most nodes of a cluster went NotReady together for 15 minutes while the API server sat behind an AWS ELB
  40. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  41. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files
  42. IL-0074 All AirMap platform services down as worker nodes went NotReady and pods crash-looped on network and DNS failures
    AirMap2018
  43. IL-0038 kubelet rollout hit a Kubernetes bug and left every node in a cluster NotReady, triggering mass pod eviction
    Oath2018
  44. IL-0072 High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state
  45. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017