  1. Symptoms

    At 3:38 PM EDT on 3 June 2026, alerts fired because both the xPRO production CMS and the main xPRO site at https://xpro.mit.edu were returning 503 errors. Fastly, in front of the site, could not connect to the Kubernetes/APISIX origin, because the origin certificate for xpro-web.odl.mit.edu had expired at 3:29 PM EDT.

    Trigger

    The origin certificate xpro-cert for xpro-web.odl.mit.edu, issued on 2026-03-05 with a 90-day validity period, expired at 3:29 PM EDT on 3 June 2026.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts for the xPRO production CMS and the main xPRO site fired at 3:38 PM EDT on the 503 errors, and a Rootly incident was created at 4:08 PM EDT.

    Remediation
    • Deleted and recreated the stale cert-manager certificate resources so that cert-manager issued a fresh origin certificate
    Action items
    • Remove the backend origin domain from the non-OpenEdX xPRO Fastly TLS subscription, so Fastly manages only xpro.mit.edu
    • Deploy the Pulumi update for the xPRO application in Production
    • Trigger cert-manager renewal of the xPRO certificate after the conflicting Fastly validation CNAME is removed
    • Consider tests or policy checks that keep cert-manager-managed origin domains out of Fastly TLS subscriptions
    • Consider alerting earlier on failed cert-manager CertificateRequests and Orders, so stale ACME failures are found before the certificate expires
    Lessons

    Reading the outage as a failed cert-manager ACME renewal was true but incomplete; the missing part was that Fastly had been set to manage validation for a backend origin domain that belonged to cert-manager. The team concluded that TLS certificates and DNS validation records need guardrails around ownership, and that public Fastly frontend domains and Kubernetes/APISIX origin domains must not be treated as interchangeable service domains in TLS automation.

  2. Symptoms

    From 11:45 UTC on 30 July 2024, a subset of customers got intermittent connection errors, timeouts and latency spikes when connecting to Microsoft services that use Azure Front Door (AFD) and Azure Content Delivery Network (CDN). The Azure Portal team saw the first service degradation at 11:47 UTC.

    Trigger

    Around 11:45 UTC the Azure network DDoS protection service was disengaging after a routine DDoS mitigation and returning traffic to its default routing to AFD, but the routes at one site in Europe could not be updated because the network control plane could not reach that site during a local power outage.

    Root cause
    Component
    Contributing factor
    Detection

    The Azure Portal team detected service degradation at 11:47 UTC and began to investigate. At 12:10 UTC network monitoring correlated the Portal incident to a network issue at one site in Europe, and networking engineers joined.

    Remediation
    • Rerouted traffic under the standard congestion playbook, which removed most of the impact by 13:58 UTC
    • Ordered the network control plane to reissue its commands to the misbehaving device, which could not be reached
    • Removed the device that kept attracting traffic from the network and scanned the network for other issues
    Action items
    • Add the missing configuration on network devices so a DDoS mitigation issue in one geography cannot spread to another
    • Improve validation and monitoring in the Azure network to detect invalid configurations
    • Improve monitoring for when the DDoS protection service is unreachable from the control plane but still serving traffic