  1. Symptoms

    At about 17:00 JST on Thursday 16 July 2026, Datadog alerted, and at almost the same time 5xx errors began to rise on the Amazon CloudFront distributions that used VPC Origins connections. Builder Work, ANDPAD's job and career service for the construction industry, became almost entirely unreachable.

    Trigger

    The Amazon CloudFront VPC Origins feature failed; AWS Health later reported a capacity constraint in an internal shared subsystem that manages connections for VPC Origins.

    Root cause
    Component
    Contributing factor
    Detection

    Datadog raised an alert, and at about the same time 5xx errors were seen rising on the CloudFront distributions that used VPC Origins.

    Remediation
    • Decided to route traffic temporarily through an internet-facing ALB without CloudFront
    • Recreated the internet-facing Ingress, attached it to the Argo Rollouts Rollout resource and promoted it
    • Created a regional WAF for the ALB with the security team
    • Created a new IngressClass with the ACM certificate, the WAF and access log settings
    • Added Ingresses for normal traffic, the admin screens and redirects, which restored routing
    Action items
    • Return to the CloudFront and VPC Origins layout while keeping a way to switch to internet-facing in code
    • Keep the internet-facing ALB, limited to approved CIDRs through spec.inboundCIDRs in IngressClassParams, so commenting out securityGroupInboundCidrs in values.yaml opens it to 0.0.0.0/0
    • Point the Terraform-managed Route53 A record back to CloudFront and keep the ALB alias commented out in code, so uncommenting and applying switches DNS to the ALB
    Lessons

    VPC Origins keeps the ALB off the internet and simplifies the traffic path, but it makes the service depend on an AWS-managed shared subsystem, and when that fails the service stops even though CloudFront is healthy. ANDPAD kept VPC Origins and instead prepared the escape route ahead of time, accepting the cost of an ALB that always runs, because recreating the Ingress and attaching it to the Rollout had taken so long during this incident.

  2. Symptoms

    At 3:38 PM EDT on 3 June 2026, alerts fired because both the xPRO production CMS and the main xPRO site at https://xpro.mit.edu were returning 503 errors. Fastly, in front of the site, could not connect to the Kubernetes/APISIX origin, because the origin certificate for xpro-web.odl.mit.edu had expired at 3:29 PM EDT.

    Trigger

    The origin certificate xpro-cert for xpro-web.odl.mit.edu, issued on 2026-03-05 with a 90-day validity period, expired at 3:29 PM EDT on 3 June 2026.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts for the xPRO production CMS and the main xPRO site fired at 3:38 PM EDT on the 503 errors, and a Rootly incident was created at 4:08 PM EDT.

    Remediation
    • Deleted and recreated the stale cert-manager certificate resources so that cert-manager issued a fresh origin certificate
    Action items
    • Remove the backend origin domain from the non-OpenEdX xPRO Fastly TLS subscription, so Fastly manages only xpro.mit.edu
    • Deploy the Pulumi update for the xPRO application in Production
    • Trigger cert-manager renewal of the xPRO certificate after the conflicting Fastly validation CNAME is removed
    • Consider tests or policy checks that keep cert-manager-managed origin domains out of Fastly TLS subscriptions
    • Consider alerting earlier on failed cert-manager CertificateRequests and Orders, so stale ACME failures are found before the certificate expires
    Lessons

    Reading the outage as a failed cert-manager ACME renewal was true but incomplete; the missing part was that Fastly had been set to manage validation for a backend origin domain that belonged to cert-manager. The team concluded that TLS certificates and DNS validation records need guardrails around ownership, and that public Fastly frontend domains and Kubernetes/APISIX origin domains must not be treated as interchangeable service domains in TLS automation.

  3. Symptoms

    From about 11:20 UTC on 18 November 2025, Cloudflare's network started failing to deliver core traffic, and Internet users visiting Cloudflare customers' sites got an error page that pointed to a failure inside Cloudflare's network. The volume of HTTP 5xx responses served by the network jumped far above its normal low baseline.

    Trigger

    At 11:05 UTC Cloudflare deployed a ClickHouse access control change that made users' existing implicit access to the underlying tables in the r0 database explicit, so the metadata of those tables became visible in system tables such as system.columns. The change was being rolled out gradually across the cluster.

    Root cause
    Component
    Contributing factor
    Detection

    The first automated test detected the issue at 11:31 UTC, three minutes after the first errors on customer HTTP traffic at 11:28. Manual investigation started at 11:32 and the incident call was created at 11:35.

    Remediation
    • Bypassed the core proxy for Workers KV and Access so they fell back to a prior proxy version, which reduced their impact
    • Stopped the automatic creation and deployment of new Bot Management feature files
    • Inserted a known good feature file into the distribution queue and deployed it globally
    • Forced a restart of the core proxy
    • Scaled control plane concurrency to clear the backlog of dashboard logins
    • Restarted the remaining services that had entered a bad state
    Action items
    • Harden the ingestion of Cloudflare-generated configuration files the same way as user-generated input
    • Enable more global kill switches for features
    • Stop core dumps and other error reports from being able to overwhelm system resources
    • Review the failure modes for error conditions across all core proxy modules
  4. Symptoms

    From 15:41 UTC on 29 October 2025, customers and Microsoft services using Azure Front Door (AFD) and Azure Content Delivery Network (CDN) got connection timeout errors and DNS resolution issues. Monitoring alerts started the investigation at 15:48 UTC.

    Trigger

    At 15:35 UTC a specific sequence of valid customer configuration changes, made across two different AFD control plane build versions, produced incompatible customer configuration metadata that was deployed to the edge sites.

    Root cause
    Component
    Contributing factor
    Detection

    The configuration protection system detected the data plane impact and blocked configuration changes at 15:43 UTC, and monitoring alerts started the investigation at 15:48 UTC.

    Remediation
    • The configuration protection system automatically blocked all new and in-flight configuration changes worldwide
    • Removed the problematic customer configurations from the latest LKG snapshot by hand
    • Blocked all customer configuration changes from propagating to the data plane
    • Deployed the updated LKG configuration across the global fleet
    • Moved Azure Portal away from Azure Front Door
    • Rebalanced traffic by hand to a few healthy edge sites, then switched back to automatic traffic management
    • Blocked all AFD customer configuration changes at the Azure Resource Manager level until safeguards were in place
    Action items
    • Fix the control plane incompatibility and the data plane bug
    • Process each customer configuration completely and synchronously before production stages
    • Add stages to the phased configuration rollout, with longer bake time between them
    • Move configuration processing on data plane servers into isolated worker processes
    • Reduce configuration propagation time from 45 minutes to about 15 minutes
    • Test backwards compatibility with configurations generated by earlier control plane builds
    • Move critical first-party infrastructure to an active-active setup with fail away
    • Isolate customer configuration and traffic with micro cell segmentation of the AFD data plane
    • Restore customer configurations within one hour by using the local configuration cache
    • Cut data plane recovery further, to about 10 minutes
    • Remove delays in Azure Service Health alerts by raising resource thresholds
    • Extend automated Azure Service Health alerts to similar classes of service degradation
    • Fail over support request systems faster so Premier and Unified customers can always open requests
    Lessons

    Microsoft describes configuration propagation risk as inherent to a global Content Delivery Network, in which route, WAF and origin changes must be deployed quickly worldwide. Both this incident and the 9 October AFD incident came from that risk. This time the incompatible metadata passed a protection system that advances only on healthy data plane signals, because the crash came later from delayed asynchronous processing. Some learnings and repair items from the earlier incident applied here as well. Microsoft advises customers to build a resilient global HTTP ingress layer that stays available during regional or network disruptions, to manage resources through the REST API or PowerShell when management portals are unavailable, and to configure Azure Service Health alerts so the right people hear about service issues.

  5. Symptoms

    On 12 November 2024, after a new version of Canva's editor was deployed at 8:47 AM UTC, the editor's object panel stayed in a perpetual loading state for many users, particularly in Asia. Then from 9:08 AM UTC to about 10:00 AM UTC canva.com was unavailable and all requests to it failed.

    Trigger

    At 8:47 AM UTC a new version of the Canva editor page was deployed, and client devices began fetching its new static assets through Cloudflare while the network path between Cloudflare's Singapore and Ashburn locations was losing packets.

    Root cause
    Component
    Contributing factor
    Remediation
    • Added a temporary Cloudflare firewall rule at 9:29 AM UTC that blocked all traffic at the CDN so new API Gateway tasks could start
    • Redirected canva.com to the status page
    • Restored traffic gradually, starting with Australian users under strict rate limits
    Action items
    • Write a runbook for rerouting, blocking and progressively restoring traffic
    • Show users a more informative error page when canva.com is unavailable
    • Raise the baseline number of API Gateway tasks and the memory of each task
    • Add load shedding rules to the API Gateway for similar traffic patterns
    • Load test the API Gateway regularly
    • Deploy the patch for the thread-locking bug in the telemetry library
    • Add multithreaded tests for the contended code path to the telemetry library microbenchmark suite
    • Use page load completion events as a second canary indicator for page asset releases
    • Experiment with adding another rollout stage to the canary to give more time to detect issues
    • Add timeouts so user requests do not wait excessively long for assets
    • Work with Cloudflare to understand the system interactions behind the incident
Check your cluster for this

These 10 cases involve CDN and edge network and Authoritative DNS servers and records. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Cloud provider outage1 case

Contributing factor
Organisation
  1. IL-0438 Builder Work became almost entirely unreachable with 504 errors when the Amazon CloudFront VPC Origins feature failed
    ANDPAD2026

Configuration change2 cases

  1. IL-0512 xpro.mit.edu returned 503 for an hour when its Kubernetes/APISIX origin certificate expired after renewal failed
  2. IL-0283 Cloudflare's core proxy returned HTTP 5xx across its network after loading an oversized Bot Management feature file

Software defect2 cases

  1. IL-0226 Azure Front Door edge servers crashed worldwide on incompatible configuration metadata, causing timeouts and DNS errors
  2. IL-0388 A Google Cloud live migration took a Discord Redis primary offline, and the failover broke API instances and then guilds

Dependency failure2 cases

  1. IL-0257 canva.com went down for about 50 minutes when 1.5 million requests per second OOM-killed every API Gateway task
    Canva2024
  2. IL-0398 GOV.UK showed "Error 503 Service Unavailable" pages for under an hour during a global outage of its primary CDN

Capacity exhaustion1 case

Organisation
  1. IL-0555 Sentry's ingestion edge regions backlogged one after another and rejected traffic in three incidents in October 2024
    Sentry2024

Breaking change in an upgrade1 case

Organisation
  1. IL-0522 An ingress-nginx chart upgrade deleted the jenkins.io Ingress and Fastly served HTTP/503 errors for hours

Faulty deployment1 case

Organisation
  1. IL-0229 bunny.net's DNS servers crashed in a loop on a corrupted routing database file and could not fetch a fix from its CDN