  1. Symptoms

    When MonotaRO raised the share of requests for the remaining endpoints of its backend API sent to EKS from 1% to 25%, Sentry filled with errors saying the API could not reach the database and outside services. The errors were about DNS name resolution, and the traffic had to be shifted back to the EC2 version.

    Trigger

    MonotaRO raised the share of requests for the remaining API endpoints routed by the ALB to the EKS version from 1% to 25%.

    Root cause
    Component
    Contributing factor
    Detection

    Sentry showed a large number of errors about connecting to the database and outside services right after the traffic share was raised.

    Remediation
    • Shifted the requests back to the EC2 version to stop the errors
    • Added an HPA to autoscale the CoreDNS pods as a stopgap, which let the migration to EKS finish
    Action items
    • Set ndots to 1 through dnsConfig in the application Deployments
    • Set cache 600 in the Corefile in the coredns ConfigMap to lengthen the CoreDNS cache TTL
    • Add lameduck 30s to the CoreDNS health plugin so CoreDNS keeps serving while it is scaled in
    • Consider reducing the differences between production and staging, weighed against cost
    Lessons

    MonotaRO assumed that a managed service would not cause problems and so skipped researching other companies' migrations, load testing and monitoring. Staging differed from production in its network layout, so ndots differed between them, and staging databases could not take a high-load test. Looking at the CoreDNS logs and resolv.conf instead of guessing found that ndots:5 made lookups of outside names try every search domain first.

  2. Symptoms

    Request latency from the Temporal Server History service, the service that starts workflow executions and records their progress, was higher and less steady than it should be on a self-hosted Kubernetes deployment. The CPU dashboard showed the history pods using less than 60 percent of their CPU, yet the same pods were being throttled.

    Trigger

    Normal load on History pods that had a CPU limit of 2 cores on 8-core nodes, with the Go runtime's GOMAXPROCS left at its default of one per node core.

    Root cause
    Component
    Contributing factor
    Detection

    A Prometheus query for CPU throttling showed the history pods throttled although their CPU usage read under 60 percent.

    Remediation
    • set the GOMAXPROCS environment variable to 2 to match the 2-core CPU limit
    Action items
    • Set GOMAXPROCS automatically from the Kubernetes CPU limit, from Temporal release 1.21.0
    Lessons

    A CPU usage graph averaged over 15 seconds or more can sit far below 100 percent while a container is being throttled, so throttling needs its own metric. A Go program in a container should have GOMAXPROCS matched to its CPU limit, or to its CPU request when it has no limit. The author recommends not using CPU limits at all.

Check your cluster for this

These 2 cases involve Container CPU limit and CoreDNS. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1