  1. Symptoms

    From 16:56 UTC on 24 August 2026, requests to DigitalOcean's Cloud Control Panel, Public API and the product management systems that depend on them failed at elevated rates. Automated monitoring flagged abnormal error rates and latency at 16:58. Running Droplets, network routing and block storage Volumes kept working.

    Trigger

    A planned migration of the database layer behind DigitalOcean's identity, authentication and authorization services made one critical authorization query run much slower than its historical baseline.

    Root cause
    Component
    Contributing factor
    Detection

    Automated monitoring detected abnormal error rates and latency at 16:58 UTC, two minutes after the authorization query slowed down.

    Remediation
    • Rerouted authorization traffic onto a single healthy processing path
    • Temporarily disabled hedged retries for the primary callers
    • Disabled the retry and amplification behaviour across the remaining affected services
    • Added read capacity for the slow authorization query
    Action items
    • Deploy circuit breakers in upstream services that detect a degraded downstream dependency and suppress hedged requests and retries
    • Audit the architecture so retry suppression and circuit breaking are enforced the same way in every control plane service
    • Add fast-fail load shedding so request queues do not saturate while a dependency is slow
    • Add telemetry alerts that spot queues backing up before customers are affected
    • Let critical authorization components run in a degraded mode on asynchronous, eventually consistent database replicas when the primary database is slow
  2. Symptoms

    At 13:08 UTC on 15 September 2025, Clerk's internal monitoring alerted on significant request failures and increased latency. Over the following days the request failures and latency spikes kept coming back while the Postgres database stayed unhealthy, with repeated spikes in database load.

    Trigger

    At 05:30 UTC on 14 September 2025 the cloud provider automatically upgraded Clerk's Postgres database to a new minor version, which changed how Postgres handled connection locks.

    Root cause
    Component
    Contributing factor
    Detection

    Internal monitoring alerted on significant request failures and increased latency at 13:08 UTC on 15 September. Shortly after the upgrade on 14 September it had already shown an increased but still acceptable database load.

    Remediation
    • Optimised several expensive queries, refined critical indexes and re-indexed the database
    • Blocked abusive traffic more aggressively for a time
    • Performed a manual minor version upgrade and increased database capacity
    • Added jitter to the connection pooling configuration so connections no longer recycled in step
    Action items
    • Evaluate other database providers that give more control over upgrades and downgrades
    • Isolate more services from each other, for example Sign Up and Sign In infrastructure from the rest of the system
    • Keep optimising the most costly database queries
    • Evaluate sharding and multi-tenant infrastructure to isolate one application from others
    Lessons

    Clerk's review found that connection metrics sampled every 60 seconds could not show a recycling pattern that lasted seconds and repeated every 15 minutes, that an attack and background jobs with similar periods pulled attention away from the database layer, that the Backend API looked healthy only because it manages far fewer connections, and that the release freeze removed the staggering of connection creation that normal deploys provide.

  3. Symptoms

    Hours after a routine switch between two clusters of Retriever, Honeycomb's storage and query engine, late on 24 July 2023, the internal SLO for Shepherd, the ingest service, began to burn slowly. The performance was only marginally slow and inconsistent, with no good explanation, so engineers treated it as minor and left it for the morning.

    Trigger

    Late on 24 July Honeycomb switched between two Retriever clusters to avoid a subtle bug, and the new cluster stopped writing the last-written timestamps the schema cache depends on. On the morning of 25 July a feature flag flip meant to move those writes back stopped the remaining writes entirely.

    Root cause
    Component
    Contributing factor
    Detection

    Hours after the cluster switch, the internal SLO for the ingest service Shepherd started burning slowly. Engineers left it for the morning, when a chart showed that Retriever's database calls updating the last-written records had stopped.

    Remediation
    • Flipped only the writes back to the other Retriever cluster with a feature flag, which did not fix the problem
    • Set up circuit breakers that denied all Shepherd traffic with a 5xx error to protect the database
    • Failed the hard-locked database over to a replica
    • Restarted all Retriever hosts so they could provide data for the cache
    • Set the last-written timestamp of every schema with traffic in the last day to now, so the schema store reloaded the cache
    • Removed the circuit breaker and restarted the query hosts that failed internal checks
    Action items
    • Finish the Retriever cluster migration and remove all code that could disable writes behind the cache
    • Explore ways to strengthen the cache further
    • Lower the contention put on the database during update storms from new schemas
    • Stabilise the performance costs of some operations in the system
    • Study instrumentation and experimentation that detect and handle such edge cases better
    Lessons

    Locally good decisions combined into the outage: the query engine wrote the timestamps because it already saw all the data, the shared cache helped scale ingest and untangle the main database, the cluster switch was done to avoid a bug, frequent deploys hid the feature flag bug, pausing deploys during the investigation kept hosts from restarting, and past near-misses made the team expect a slow failover. Feature flags, frequent deploys, pausing deploys during incidents and learning from near-misses all contributed, although they are among the practices Honeycomb trusts most. For a rare lockup of this kind a database failover is the fastest recovery. Several recent Honeycomb incidents started from trying to avoid a subtle bug.

  4. Symptoms

    At 13:00 UTC on Monday, June 27, 2022, Basecamp 3 became extremely slow, then showed error pages, and then stopped working altogether. Basecamp 2 and Basecamp Classic kept working normally.

    Trigger

    At 13:00 UTC, when Basecamp 3 sends scheduled notifications in massive batches, a rush of demanding queries reached the primary database and started a cascade of heavy lock contention.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw the Basecamp 3 primary database become completely congested within 30 seconds of 13:00 UTC and responded immediately.

    Remediation
    • Paused and disabled parts of Basecamp 3, such as delaying progress report emails
    • Failed over from the primary database to a replica, which brought Basecamp 3 back until it tipped over again
    • Put Basecamp 3 into maintenance mode
    • Set hard limits on database query time
    • Brought features back online step by step with the query limits in place
    Action items
    • Keep hard limits on database query time so slow queries fail instead of piling up
    • Tune the limits on concurrency
    • Treat top-of-the-hour database load spikes from scheduled batches as unacceptable
    • Reduce the number of parallel workers for some scheduled jobs
    • Let some scheduled activities run over several minutes instead of all at once
    • Move bursty queries from the primary database to read-only replicas
    • Fix the quiet performance regressions found in a review of the past year of database metrics
    • Find and spread out other bursty activities that concentrate load on the database
    • Tune the database for more predictable behaviour under heavy load and high concurrency
    • Add observability into the database's internal locking and transaction states
    • Build tools to switch off high-load Basecamp 3 features selectively during an incident
    • Run operational fire drills for a wedged database
    • Evaluate upgrading the database software and hardware
    • Set service level objectives for the components behind Basecamp 3
    • Hold quarterly performance and load reviews to catch slow, subtle changes
    Lessons

    A system running just past its limits can flip from stable to unstable without any particular trigger, and steady growth plus small regressions that raised no alarm had brought Basecamp 3's primary database to that point. Under lock contention, terminating queries does not relieve the database, because rolling back their transactions waits on the same locks. The team struggled to respond with confidence because there was no single clear cause and little visibility into the database's internals.

  5. Symptoms

    On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.

    Trigger

    At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.

    Root cause
    Component
    Contributing factor
    Detection

    At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.

    Remediation
    • Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
    • Moved API traffic that could use read replicas to the secondary data center by hand
    • Sent authentication calls fully back to the primary data center when the dashboard got worse
    • Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
    • Ramped the turned-down services back up so asynchronous processing could catch up
    Action items
    • Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
    • Redesign the user sessions system so dashboard traffic can be steered between data centers
    • Change the auto-remediation configuration so a database replica is not promoted so quickly
    • Tune each system involved to be more resilient to failures of its dependencies
    Lessons

    Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.

Check your cluster for this

These 8 cases involve Database and Database replication. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Configuration change1 case

Organisation
  1. IL-0561 DigitalOcean's Cloud Control Panel and Public API returned up to 25% errors in two windows as authorization timed out

Breaking change in an upgrade1 case

Organisation
  1. IL-0498 Clerk's Postgres database had load spikes every 15 minutes and requests failed and slowed intermittently for four days
    Clerk2025

Software defect2 cases

Organisation
  1. IL-0217 Honeycomb's main MySQL database locked up under cache-miss reads and ran out of connections, a 68-minute total outage
  2. IL-0303 GitHub's MySQL master failed over to a node with a cold buffer pool during a schema migration and GitHub.com went down
    GitHub2012

Capacity exhaustion2 cases

Component
  1. IL-0301 Basecamp 3's primary database went into total gridlock at the top of the hour and Basecamp 3 went down twice
  2. IL-0383 PagerDuty's shared Cassandra cluster degraded during a repair, delaying notifications and losing incoming events

DNS or network fault1 case

Organisation
  1. IL-0240 Cloudflare API requests failed and the dashboard slowed for hours after the authentication database lost its replicas

Hardware failure1 case

  1. IL-0323 A RAID battery backup unit failure crashed db1075, the MariaDB primary of section s3, and every s3 wiki went read-only