IL-0306A Neon pageserver's EC2 instance failed without warning and Postgres databases of 0.4% of us-east-1 projects stalledNeon2024- Symptoms
At 17:28 on 2024-08-14 the EC2 instance pageserver-7.us-east-1.aws.neon.tech stopped responding. Neon customer databases attached to that pageserver stalled whenever they needed to read data that was not already in their Postgres buffer cache.
- Trigger
The EC2 instance hosting pageserver-7 in us-east-1 failed without the advance warning AWS usually gives before a hardware failure.
- Root cause
- Component
- Contributing factor
- Detection
Several alerts fired at 17:38, in Slack and as automatic pages to the on-call engineers: the pageserver stopped answering metric scrapes, the control plane API error rate rose, and user operations such as starting endpoints and creating timelines got stuck.
- Remediation
- Migrated the 17037 projects on pageserver-7 to other pageservers in the region with a semi-manual script
- Brought back by hand about 20 projects whose in-flight operations blocked the migration
- Action items
- Move all paying customers onto the storage controller sooner than planned
- Finish moving the existing pageserver infrastructure under the storage controller
- Lessons
Neon's first control plane design, in which operations always run to completion, cannot drive a fast response to node failures at scale, because operations that depend on physical machines may never complete. A human decision in the loop and alerts with several minutes of delay made the response too slow; the storage controller, with its own heartbeats and automatic rescheduling, moves work off a failed pageserver in seconds.
This case involves Database and Database failover manager. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.