IL-0136A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hoursMicrosoft Azure2026- Symptoms
From 10:03 UTC on 29 September 2026, requests to Azure OpenAI Service, Foundry Agent Service, Foundry Models and Azure AI services in Sweden Central failed intermittently, took longer, or returned HTTP 500 and 503 errors. At 10:17 UTC service monitoring raised an alert on elevated failure rates for Azure OpenAI Service requests in the region.
- Trigger
At about 09:38 UTC a planned deployment of an internal service in Sweden Central cleared that service's caches during the region's peak traffic hours.
- Root cause
- Component
- Contributing factor
- Detection
Service monitoring detected elevated failure rates for Azure OpenAI Service requests in the region at 10:17 UTC and alerted the engineering teams; engineers were engaged at 10:28 UTC.
- Remediation
- reconfigured the backend service's automated health check so it no longer depended on remote connectivity, which stopped the restart loop
- Action items
- Reconfigure the backend service's automated health check so it no longer depends on connectivity to its database layer
- Add monitoring and alerting on the load and latency of the caching layer used by the backend service
- Update troubleshooting and procedural guidance for connection exhaustion scenarios for on-call engineers
- Add throttling and rate limiting to protect the backend service from sudden traffic increases (estimated October 2026)
- Increase the resource capacity of the caching layer used by the backend service across regions (estimated October 2026)
- Improve diagnostic metrics and automated detection to identify such issues more quickly (estimated October 2026)
- Partition the caching layer used by the backend service to increase its throughput (estimated December 2026)
- Lessons
A health check that depends on a remote dependency turns a dependency problem into a restart loop: instances that cannot reach the database are killed, the remaining ones take more load and retries, and adding instances or resources does not help until the check itself is changed. Clearing a cache during peak traffic can multiply load on the backend behind it, especially when cache-read defects let lookups bypass the cache. Connection exhaustion was hard to see because the existing network and diagnostic metrics did not show it.
IL-0100PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queriesPostHog2025- Symptoms
On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.
- Trigger
On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.
- Root cause
- Component
- Contributing factor
- Detection
On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.
- Remediation
- rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
- throttled connections and Redis writes on 21 October
- halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
- rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
- increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
- added retry limits to Envoy between the load balancer and the service
- moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
- added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
- Action items
- Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
- Investigate separating the flags Redis instance from the application Redis instance
- Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
- Make the feature flags team hard code-owners for flags-related code
- Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
- Add missing alerts on existing service and infrastructure metrics
- Make readiness checks validate dependencies that degrade under load, for example by pinging the database
- Rate-limit cache population so it cannot overwhelm Redis
- Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
- Build a production-scale load testing framework
- Build progressive rollout infrastructure to limit blast radius
- Document Postgres-to-Redis data flows and write runbooks for data transfer storms
- Lessons
Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.
- Symptoms
At 11:48 PM PDT on 19 October 2025, every system that reached DynamoDB in us-east-1 through the public regional endpoint started getting DNS failures and could not connect. This included customer traffic and internal AWS services that depend on DynamoDB. DynamoDB global table replicas in other regions still answered but fell behind in replication to and from us-east-1.
- Trigger
One DNS Enactor, slowed by unusually high retry delays, applied a much older DNS plan to the regional DynamoDB endpoint just as another Enactor that had applied the newest plan ran its clean-up, which deleted that older plan and with it every IP address of the endpoint.
- Root cause
- Component
- Contributing factor
- Detection
DNS failures to DynamoDB began immediately at 11:48 PM PDT and the engineering teams of affected AWS services were engaged at once; by 12:38 AM they had identified DynamoDB's DNS state as the source. The later NLB health check problem was detected by monitoring at 6:52 AM.
- Remediation
- applied temporary mitigations by 1:15 AM that let some internal services reach DynamoDB and repaired key internal tooling
- restored all DynamoDB DNS information by 2:25 AM through manual operator intervention
- throttled incoming work and selectively restarted DWFM hosts from 4:14 AM so droplet leases could be re-established
- reduced the load on Network Manager to bring network configuration propagation times back to normal by 10:36 AM
- disabled automatic health check failover for NLB at 9:36 AM, and re-enabled it at 2:09 PM after EC2 recovered
- relaxed the EC2 request throttles from 11:23 AM until all EC2 APIs and launches were normal at 1:50 PM
- Action items
- Disable the DynamoDB DNS Planner and DNS Enactor automation worldwide
- Fix the race condition and add protections against applying incorrect DNS plans before re-enabling the DNS automation
- Add a velocity control to NLB that limits how much capacity a single load balancer can remove when health check failures cause availability zone failover
- Build an additional EC2 test suite that exercises the DWFM recovery workflow at scale
- Improve throttling in EC2 data propagation systems so incoming work is rate limited by the size of the waiting queue
- Lessons
A single DNS record that automation can empty is enough to take a widely used regional endpoint off the network, and every service built on it fails in turn. A check made once at the start of a long operation can be stale by the time the operation writes its result. Recovery of the dependency is not recovery of the dependents: systems that lost state during the outage, such as EC2's droplet leases and network propagation backlog, can collapse under their own catch-up work, and container services that rely on new instance launches keep failing to launch and scale until that work is done.
IL-0024Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three timesHugging Face2024- Symptoms
At 08:45 CET on 22 April 2024 the Hugging Face Hub became unstable, and by 09:30 it was unresponsive. For most users the website was slow or could not be reached at all.
- Trigger
Bursts of requests to revision endpoints that read heavily from the *_info_cache collections: a call to https://huggingface.co/api/datasets/lighteval/mmlu/revision/main rose sharply right before the first crash, and a call to https://huggingface.co/api/models/sentence-transformers/all-mpnet-base-v2/revision/main, a model with 300+ associated spaces, lined up with the crash at 21:30 on 23 April.
- Root cause
- Component
- Contributing factor
- Detection
Instability started at 08:45 on 22 April and the Hub was unresponsive by 09:30; the team followed MongoDB Atlas metrics and a MongoDB support case. The root cause was found days later from a new graph of requests per URL.
- Remediation
- Added a firewall rule blocking all requests with a Java/* user agent
- Disabled the quicksearch feature on the Hub
- Scaled the MongoDB Atlas cluster by hand from tier 2 to tier 3
- Switched the Hub to maintenance mode with a 503 page through AWS WAF and blocked incoming traffic
- Scaled all Hub pods down to 0 and brought them back
- Set an aggressive rate limit
- Added timeouts to requests and reworked database queries that were slow or returned large bodies
- Action items
- Add timeouts to requests based on their usual completion time
- Optimise requests that took too long or returned a large body, and rework poorly designed database queries
- Remove old unused indexes from the database
- Build new dashboards and monitoring metrics
- Move the *_info_cache collections to Redis
- Make it possible to abort any database request when the client aborts theirs
- Lessons
Finding the root cause took two to three days: the existing charts did not show it, and a per-URL request breakdown did. Not cancelling database work when a client goes away turns a strained database into a thundering herd. A close inspection of the database exposed architectural flaws and bottlenecks, such as a collection with large unused indexes, and taught the team which metrics need closer watching to anticipate crashes. Unrelated failures happening at the same time added to the stress and made restoring service harder.
- Symptoms
Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.
- Trigger
An abnormally large number of queries arrived from many separate connections within a few minutes.
- Root cause
- Component
- Contributing factor
- Detection
Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.
- Remediation
- Scaled the ingest fleet up manually and aggressively
- Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
- Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
- Action items
- Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
- Decide on the projects that will address these failure paths
- Lessons
Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.
These 5 cases involve Application database and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause3
Faulty deployment1 case
- Component
- Contributing factor
- Organisation
Capacity exhaustion2 cases
- Contributing factor
- Organisation
IL-0100PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queriesPostHog2025IL-0202A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recoverHoneycomb2023
Software defect2 cases
- Component
- Contributing factor
- Organisation
IL-0150A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1IL-0024Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three timesHugging Face2024