  1. Symptoms

    On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.

    Trigger

    On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.

    Root cause
    Component
    Contributing factor
    Detection

    On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.

    Remediation
    • rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
    • throttled connections and Redis writes on 21 October
    • halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
    • rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
    • increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
    • added retry limits to Envoy between the load balancer and the service
    • moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
    • added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
    Action items
    • Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
    • Investigate separating the flags Redis instance from the application Redis instance
    • Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
    • Make the feature flags team hard code-owners for flags-related code
    • Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
    • Add missing alerts on existing service and infrastructure metrics
    • Make readiness checks validate dependencies that degrade under load, for example by pinging the database
    • Rate-limit cache population so it cannot overwhelm Redis
    • Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
    • Build a production-scale load testing framework
    • Build progressive rollout infrastructure to limit blast radius
    • Document Postgres-to-Redis data flows and write runbooks for data transfer storms
    Lessons

    Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.

  2. Symptoms

    From about 10:30 UTC on 30 August 2023, customers had trouble accessing or using Azure, Microsoft 365 and Power Platform services in Australia East. The affected Azure services included Azure Kubernetes Service (AKS) along with storage, SQL Database, Cosmos DB, virtual machines and Azure Resource Manager.

    Trigger

    At 08:41 UTC a lightning strike on electrical infrastructure about 18 miles away caused a utility voltage sag that shut down the cooling chillers of datacenters in one Australia East availability zone; 13 chillers failed to restart automatically and five could not be restarted, so two data halls overheated and their infrastructure was shut down.

    Root cause
    Component
    Contributing factor
    Detection

    Cosmos DB impact was detected by monitoring at 10:47 UTC, first automated communications went to Azure Service Health at 10:48 UTC, the public Azure Status page was updated at 11:30 UTC, and all subscriptions in Australia East were sent portal communications at 11:36 UTC.

    Remediation
    • shut down the remaining networking, compute and storage in the two affected data halls so the chilled water loop could cool down
    • restarted the five chillers manually at 12:12 UTC
    • restored power to all hardware by 15:10 UTC and brought infrastructure back in phases
    • restored AKS operations through the recovery of the SQL Database operation queue, with no other mitigation
    Action items
    • AKS: convert all operation queue SQL Database databases to be zone redundant (estimated September 2023)
    • AKS: replace all cross-region SQL Database queue usage with zone-redundant Service Bus queues (estimated September 2023)
    • Change the control timing logic of the Chiller Management System so chillers do not fail to restart after voltage fluctuations
    • Change the emergency procedure for manual restarts of simultaneous chiller failures from an adjacent sequence to a load-based sequence per data hall
    • Increase technician staffing at the datacenter as a temporary measure for manual chiller restarts
    • Storage: optimise the large-scale recovery process and update troubleshooting guides (estimated December 2023)
    • Azure Service Fabric: improve reliability of SQL Database tenant ring recovery (estimated December 2023)
    • SQL Database: review the trigger criteria of auto-failover groups (estimated October 2023)
    • SQL Database: upgrade internal tooling to enable mass migration of databases (estimated December 2023)
    • Cosmos DB: optimise Service Managed Failover for single-region-write accounts (estimated November 2023)
    • ARM: complete the migration of its storage layer to the zonally redundant architecture (estimated December 2023)
    • Incident management: harden readiness, process and playbook for power-down scenarios (estimated October 2023)
    Lessons

    A control plane spread across availability zones still fails with a zone when one of its dependencies, here the SQL Database operation queue, is not zone redundant. When a second region uses the same database, the failure crosses into that region as well. Workloads already running were not expected to be affected; what stopped was everything that needs the managed service's control plane, such as scaling and cluster changes.

  3. Symptoms

    Right after an updated RedisFailover resource was rolled out, the large Redis database lost all its data and the service went down; the data had to be restored from a backup taken just before the change.

    Trigger

    A RedisFailover change that raised the number of Redis replicas from one to two and, in the same rollout, lowered the containers' memory requests and limits from 22 GB to 19 GB.

    Root cause
    Component
    Contributing factor
    Remediation
    • restored the Redis data from the backup prepared before the rollout
    Action items
    • Report the readiness probe flaw to the Redis Operator project and test the developers' fix
    • Reconsider the use of the Spotahome Redis Operator
    • Clean up the Redis databases and fix the application code that created the excess keys
    • Consider Redis built-in clustering and sharding
    Lessons

    Changing the replica count and the pod resources in one rollout turned a seemingly harmless change into a rolling restart of the only pod with data while the new replica was still empty. A readiness probe that only checks that Redis answers a ping does not tell whether a replica has finished syncing. Operators for critical stateful components need to be evaluated for maturity before production use, and the dump.rdb file should be backed up before any change to the Redis cluster.

  4. Symptoms

    Users reported that their jobs were not starting, with some sign that image pulls were involved. Many pods across the cluster were in error states related to image pulls, while applications that were already running were not affected.

    Trigger

    A change to the permissions on a storage bucket that one application needed to read. The application could no longer start, and its DaemonSet, running on roughly a thousand nodes of the cluster, went into a crash loop with imagePullPolicy: Always, so every restart pulled the image again although it was already on the node.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that their jobs were not starting; monitoring had not caught it first.

    Remediation
    • replaced the affected NAT instances so registry traffic came from new source IPs
    • reconfigured the static IPs and firewall rules so applications could reach the Cloud SQL database again
    Action items
    • Add an admission webhook that rejects floating image tags, starting with latest
    • Apply the image tag webhook to workload objects only, not to pods, after it blocked pods created by in-cluster controllers
    Lessons

    The speakers' takeaway is to be very careful with DaemonSets in large clusters: they say they had broken everything DaemonSets depend on, including DNS, Vault and the image repository, and that it is very easy to break things when managing them by the thousand. imagePullPolicy: Always made every crash-loop restart pull the image again. Sending all registry traffic through three NAT instances put the whole region behind three source IPs, which the registry rate-limited, and changing those IPs cut the connections to a critical database reached over the internet through them. An admission webhook on pods rejects the pods that controllers in the cluster create, where no user sees the error.

  5. Symptoms

    On Friday, January 18, Moonlight's API began returning occasional errors that looked like connection problems with its Redis database. The API checks Redis on every authenticated request to validate the session. At the same time the Kubernetes monitoring reported some nodes and pods as unresponsive.

    Trigger

    The Kubernetes scheduler put several CPU-heavy pods on the same node, including all three replicas of the website and the server-side rendering pods.

    Root cause
    Component
    Contributing factor
    Detection

    API errors that looked like Redis connectivity problems, and Kubernetes monitoring that showed nodes and pods as unresponsive. Google Cloud Support later found the link between sustained 100% CPU and kernel panics.

    Remediation
    • added anti-affinity rules to all major deployments so their pods spread across nodes
    Action items
    • Keep working with Google Cloud support to find and fix the cause of the node kernel panics
    Lessons

    Three replicas give no fault tolerance if the scheduler places them all on one node; anti-affinity rules make the spread explicit. A node failure that comes from the workload itself moves with the workload when the scheduler reschedules it.

Check your cluster for this

These 5 cases involve Application database and Pod scheduling and placement. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause3

Capacity exhaustion3 cases

  1. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  2. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  3. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down

Cloud provider outage1 case

Organisation
  1. IL-0145 A power sag and chiller failure in one Australia East availability zone took down the AKS control plane's compute and its non-zone-redundant SQL Database operation queue, blocking AKS create, update and delete operations in Australia East and Australia Southeast

Software defect1 case

Organisation
  1. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020