Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    At 5:27 AM UTC on 17 February 2026 part of OpenRouter's users started getting 500 errors on all API endpoints, and from 5:40 AM many requests failed with 401 "User not found" errors although their API keys were valid. The chatroom was degraded at the same time. The same pattern came back at 7:36 AM UTC on 19 February.

    Trigger

    The third-party caching layer in front of API key lookups dropped all of its connections to OpenRouter's database and began returning errors.

    Root cause
    Component
    Contributing factor
    Detection

    An internal alert fired one minute after impact began on 17 February, at 5:28 AM UTC, and two minutes after it began on 19 February, at 7:38 AM UTC, and the response team came online to investigate.

    Remediation
    • Deployed WAF rules to block the denial-of-service attack running at the same time on 17 February
    Action items
    • Add circuit breakers that detect caching layer failures, limit their blast radius and repopulate a cold cache in a controlled way
    • Return 503 instead of 401 when an authorization lookup cannot complete because of an infrastructure problem
    • The caching provider fixes the failure mode that caused both incidents
    • Roll out a fallback caching mechanism so OpenRouter survives even extended downtime of the caching layer
    Lessons

    Answering an infrastructure failure with an authentication error made customers debug API keys that were fine, so error codes have to say what actually failed. Attributing the first outage to a concurrent denial-of-service attack, because the caching dependency had always been reliable, left the real fault in place until it recurred two days later. OpenRouter holds that redundancy against failures in its dependencies is its own responsibility, not the provider's.

  2. Symptoms

    On 15 January 2025, from about 09:55 to 11:36 CET, a database outage at Magic Pages took down customer websites. It began when the founder tried to reconnect a failed third node to the high-availability MySQL cluster and the database server reported ambiguous errors about missing metadata information.

    Trigger

    One of the three nodes of the MySQL cluster went down, and reconnecting it failed with errors about missing metadata information.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the storage server to fix PVC provisioning
    • Let the MySQL nodes restore and sync with each other for about 45 minutes to rebuild the cluster metadata
    • Cleaned up the corrupted cluster metadata
    • Redeployed MySQL Router
    Action items
    • Monitor the health of the storage system more closely
    • Improve the failover procedures for MySQL Router
    • Investigate and fix the status page so it shows reliable information
    Lessons

    The cluster survived the first node failure as designed and lost no data, but its metadata turned out to be a single point of failure. Better monitoring of PVC health could help prevent similar issues, the 45-minute recovery leaves room for improvement, and the status page has to detect failing customer sites reliably.

Check your cluster for this

These 2 cases involve Database and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1