  1. Symptoms

    At 7:13 UTC on 20 October 2025, PlanetScale's continuous tests in production started failing because they could not create new database branches. The service that creates, resizes and configures database branches was unavailable, a near-total control plane outage, while existing database branches kept their capacity and connectivity.

    Trigger

    The incident started with a DNS misconfiguration at one of PlanetScale's service providers. An Amazon DynamoDB outage impacted AWS STS, and several hours of capacity constraints and network instability in AWS us-east-1 followed.

    Root cause
    Component
    Contributing factor
    –
    Detection

    PlanetScale's continuous testing in production started failing and alerted engineers at 7:13 UTC. At 10:05 UTC an alert fired for a Kubernetes operator in a large single-tenant customer installation exhausting its resources.

    Remediation
    • Disallowed new databases in us-east-1 and made us-east-2 the default region for new databases
    • Delayed new backups and cancelled pending backups that were waiting for an EC2 instance
    • Advised PlanetScale Managed customers with vtgate autoscaling to shed load
    • Paused draining and terminating EC2 instances older than 30 days
    • Kept vacant EC2 instances for reuse instead of terminating them
    • Bin-packed vtgate processes more tightly for customers with autoscaling
    • Sent manual reparent requests to move primaries to healthier availability zones
    • Restarted the edge load balancer and vtgate processes that did not recover after the partitions healed
    Action items
    • Understand and become resilient to the failure modes of SaaS dependencies for CI/CD, SSO, web application hosting and incident communication
    • Investigate more ambitious ways to reduce runtime dependence on internal and AWS services
    • Look into using all six us-east-1 availability zones to tolerate zonal outages and partitions
    Lessons

    Keeping the control plane separate from the data plane meant the control plane outage did not affect customer databases, and redundancy, automated failover and zonal traffic routing limited the effect of the network partitions. Network partitions are hard to reason about, test and tolerate: with three availability zones a system survives losing one zone only if the other two can still reach each other reliably.

  2. Symptoms

    On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.

    Trigger

    At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.

    Root cause
    Component
    Contributing factor
    Detection

    At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.

    Remediation
    • Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
    • Moved API traffic that could use read replicas to the secondary data center by hand
    • Sent authentication calls fully back to the primary data center when the dashboard got worse
    • Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
    • Ramped the turned-down services back up so asynchronous processing could catch up
    Action items
    • Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
    • Redesign the user sessions system so dashboard traffic can be steered between data centers
    • Change the auto-remediation configuration so a database replica is not promoted so quickly
    • Tune each system involved to be more resilient to failures of its dependencies
    Lessons

    Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.

  3. Symptoms

    On a Friday evening in December 2019, Razorpay's internal monitoring alerted on an unusually high number of 5xx errors. The SRE team found that the main application, called API, could not connect to its RDS MySQL database, but within about 110 seconds the application recovered by itself and the alerts stopped. The RDS logs showed that the master instance had gone through a Multi-AZ failover.

    Trigger

    The master instance of the API application's RDS MySQL database went through a Multi-AZ failover to its standby in another availability zone.

    Root cause
    Component
    Contributing factor
    –
    Detection

    An internal monitoring alert on unusually high 5xx errors, then alerts that replication had failed on all replicas. The data loss was found the next day by matching the database against the application trace logs.

    Remediation
    • Moved all read replica traffic to the master instance
    • Recreated all five read replicas after a six-hour full snapshot and moved traffic back to them
    • Recovered the missing queries from the binary logs and corrected the data stored in RDS
    • Changed innodb_flush_log_at_trx_commit on the master from 2 to 1
    Lessons

    With innodb_flush_log_at_trx_commit set to 2, Razorpay had been open to data loss on any failover all along, even though RDS Multi-AZ copies everything on the primary's disk to the standby. The incident also taught the team how RDS runs a Multi-AZ setup and its failovers.

  4. Symptoms

    Reports came in of more WORKER_JOB_ERROR errors, which tell Transloadit there is a communication problem between its Uploaders, the machines that receive files and orchestrate Assemblies, and its Drones, the machines that run encoding tasks. Many Assemblies became much slower because retries with exponential back-off kicked in, and a few could not be replayed.

    Trigger

    A steep increase in HLS traffic, together with more Drones online processing the same volume faster, which put more load on the central Redis nodes.

    Root cause
    Component
    Contributing factor
    Detection

    Reports of an increased number of WORKER_JOB_ERROR errors.

    Remediation
    • Re-added lost messages and relaxed heartbeat monitoring as a stopgap
    • Upgraded Redis to the latest stable version
    • Doubled the Redis cluster to six nodes and then added three more, which made it worse
    • Brought the number of read replicas down to one, which cut traffic and failure rates
    • Capped how far Drones scale up in each region
    Action items
    • Add logging and alarms for approaching saturation
    • Find ways to decentralise the traffic between the Redis nodes and the Drones and Uploaders
    • Add sharding per Uploader on top of the sharding per region
    Lessons

    To handle more traffic Transloadit had to use fewer Redis nodes, not more: each added replica multiplied the replication traffic from the single leader that takes every write, so scaling up the number of nodes was the wrong call. Bandwidth had not been among the monitored Redis metrics.

Check your cluster for this

These 4 cases involve Database replication and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.