Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    A distributed training task on 128 machines in ByteDance's production environment slowed down severely for 40 minutes but kept running, holding thousands of V100 GPUs at reduced speed. The alerting in place notified engineers only when a task stopped completely, so the slowdown itself raised no alert.

    Trigger

    The PCIe link of one machine degraded from 6.4Gbps to 4Gbps during the training task.

    Root cause
    Component
    Contributing factor
    Detection

    No alert fired because alerts came only when a task stopped. Engineers from several teams found the faulty machine by manual diagnosis, which took 40 minutes.

    Action items
    • Detect faulty machines automatically during training by comparing each machine's per-second monitoring metrics with the other machines (Minder)
    Lessons

    Some faults slow a task without stopping it, and alerting that waits for a halted task misses them. Logs alone are incomplete because they do not contain monitoring metrics such as PFC packet rates, and no single metric reveals every fault type, so ByteDance compares machines with each other on several metrics and treats a difference that lasts for minutes as a fault.

  2. Symptoms

    On DeepSeek's Fire-Flyer 2 training cluster of 10,000 PCIe A100 GPUs, Xid 74 NVLink errors, which occur mainly on the NVLink Bridge between pairs of GPUs, were the most common GPU Xid error and occurred several orders of magnitude more often than other hardware faults. InfiniBand link flash cuts disrupted application communication and sometimes failed training tasks, and computational and GPU memory errors that ECC did not detect caused gradnorm spikes, loss explosions and even non-convergence of models.

    Root cause
    Component
    Contributing factor
    –
    Detection

    Xid errors were read from the NVIDIA driver's messages in the kernel or event log. A validator run weekly by the automatic operations system tested every node, and diagnosis tools such as hostping were integrated into the platform.

    Remediation
    • Reset the GPU to clear most GPU memory ECC errors, relying on A100 row remapping
    • Reset the GPU or rebooted the node after uncorrectable GPU errors
    • Ran a fieldiag test after Xid 119 and sent most such GPUs for RMA
    • Removed nodes that failed the weekly validator from the scheduling platform
    • Resumed interrupted training from checkpoints saved about every 5 minutes
    Lessons

    The best way to keep devices stable is to find problems before they happen, which is why the validator runs weekly. GPU ECC faults far outnumber CPU ones and need to be handled quickly so that performance and accuracy are not affected. Software-looking Xid errors such as illegal memory access may come from corrupted memory, so hardware faults should be considered once software bugs are ruled out. Whether to install NVLink should depend on actual need because of its drawbacks.

Check your cluster for this

These 2 cases involve InfiniBand fabric and GPU hardware and memory. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.