By root cause
2
DNS or network fault
1 case
Component
Cloud load balancer
conntrack table
Horizontal pod autoscaler
Ingress controller
kube-proxy
Pod termination
Contributing factor
Unreviewed defaults
Organisation
Lotte E-commerce
IL-0178
On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB
Lotte E-commerce
2022
Software defect
1 case
Component
etcd
Ingress controller
Kubernetes API server
Persistent volumes and stateful sets
Contributing factor
Unreviewed defaults
Organisation
Nordstrom
IL-0072
High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state
Nordstrom
2017
한국어