  1. Symptoms

    At 08:00 UTC on 2021-09-06 every service in DFDS's Kubernetes cluster answered with 404. Investigation started five minutes later.

    Trigger

    The automated Kubernetes node rollover on 2021-09-06 restarted all the Traefik v2 pods, five days after a malformed IngressRoute manifest had been applied.

    Root cause
    Component
    Contributing factor
    Detection

    All services returned 404 from 08:00 UTC and root cause investigation started at 08:05. Time to detection was 5 minutes.

    Remediation
    • changed the ALB health check path, which made the targets healthy but did not stop the 404s
    • rolled back by hand to Traefik v1 as the main ingress controller
    • deleted the malformed IngressRoute by hand and confirmed the Traefik v2 bug
    • applied the changes upstream
    Action items
    • Upgrade Traefik to v2.5, where the bug is fixed, and verify that it removes the bug
    • Change the Traefik v2 health check path to something more robust
    • Set up an external liveness probe on the ingress controller
    • Consider workload segmentation to limit the blast zone
    • Look into monitoring the Traefik v2 API for rapid changes
    • Look into smoke testing during and after node rollover
    Lessons

    A malformed IngressRoute did nothing visible for five days and then took down all ingress when every Traefik v2 pod had restarted during a node rollover. Because Traefik v2 failed gracefully, the first signals pointed at the ALB health checks instead of at Traefik. On incident handling, the team concluded that appointing an incident manager could have helped, that the war room meeting should be recorded and a log book kept, that people not involved should only make suggestions in writing, and that a short first round of sharing thoughts and gut feelings is useful.

  2. Symptoms

    After the switch to Traefik v2, functional tests indicated that everything was fine, and this was reported on Slack at 08:44 UTC. The first sign of trouble came at 09:26 UTC, when a developer reported a high count of HTTP 307 redirects, especially on the Okta service. At 09:32 UTC the team learned that the online booking system was down.

    Trigger

    At 08:22 UTC the AWS load balancers were updated to send requests to the new Traefik v2 reverse proxy as part of the migration away from Traefik v1.

    Root cause
    Component
    Contributing factor
    Detection

    A developer reported a high count of HTTP 307 redirects, in particular on the Okta service, at 09:26 UTC, 64 minutes after the change; six minutes later the team was told the online booking system was down. The functional tests run after the switch had not caught it.

    Remediation
    • Rolled back the switch to Traefik v2, putting rollback ahead of investigation because of how critical the booking system is
    Action items
    • Consider how critical announcements can be made more visible
    • Consider whether the ALBs used for testing should have been shared with the teams so they could test their own scenarios
    Lessons

    Cloud Engineering cannot test every application scenario on its own, even after testing its own applications for weeks. A header that changes value behind a new ingress controller, here x-forwarded-proto going from https to http, can break an authentication flow while basic functional tests still pass. DFDS asks whether diffing request headers before and after the migration would have shown the problem in advance.

Check your cluster for this

These 2 cases involve Cloud load balancer and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause2