  1. Symptoms

    From 16:27 UTC on 21 August 2025, users connecting to Cloudflare from servers in AWS us-east-1, or receiving connections from Cloudflare there, saw high latency, packet loss and failures to reach origins. Cloudflare's network team was alerted to internal congestion in Ashburn (IAD) at 16:44 UTC.

    Trigger

    At about 16:27 UTC a single customer began sending many requests from AWS us-east-1 to Cloudflare for objects in Cloudflare's cache, doubling the total traffic from Cloudflare to AWS.

    Root cause
    Component
    Contributing factor
    Detection

    Cloudflare's network team was alerted to internal congestion in Ashburn (IAD) at 16:44 UTC, and an incident was raised for customer impact at 17:45 UTC.

    Remediation
    • Rate limited the single customer whose traffic caused the surge
    • Took further traffic engineering actions that fully resolved the congestion
    • Asked AWS to revert its BGP prefix withdrawals, which AWS finished at 20:07 UTC
    Action items
    • Build a mechanism to deprioritise a customer's traffic when it congests the network enough to affect others
    • Speed up the Data Center Interconnect upgrades to add network capacity
    • Work with AWS so the two companies' BGP traffic engineering actions do not conflict
    • Build a traffic management system that gives each customer a network resource budget and automates the manual actions used here
    Lessons

    Cloudflare concludes that it must isolate customers better so that no single customer can take over shared network resources and degrade the platform for others, and that its network needs enough capacity to meet demand. It describes the outage as the result of insufficient network congestion management during an unusual high-traffic event.

  2. Symptoms

    In May 2021 some users of seek.com.au got errors when they searched for jobs, for 16 minutes. SEEK was in the middle of moving the traffic between two VPCs, the one that carried searches, from a VPC peering connection to an AWS Transit Gateway, and the team noticed quickly that search was broken.

    Trigger

    In the second step of the migration, SEEK changed the routing table of the first VPC to use the transit gateway while the second VPC still routed over the peering connection, so the two directions of each connection took different paths.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed soon after the routing change that search on seek.com.au was not working.

    Remediation
    • Rolled back the migration of the search traffic's peering connection to the transit gateway
    Action items
    • Lower the MTU of EC2 instances to 8500, on Amazon Linux 2 with a script at /sbin/ifup-local that runs whenever a network interface comes up
    Lessons

    A transit gateway has a smaller MTU than a same-region peering connection, drops oversized packets silently and clamps the MSS only on packets that cross it. When a migration leaves the two directions of a TCP connection on different paths, the clamp lands on the wrong side of the handshake and large packets are lost; the fix is not to send packets larger than 8500 bytes.

  3. Symptoms

    From 7:30 AM JST on 2 September 2021, AWS Direct Connect customers saw intermittent connectivity problems and elevated packet loss on traffic going to their VPCs in the Tokyo (AP-NORTHEAST-1) Region. Internal AWS alarms on Direct Connect packet loss fired at the same time.

    Trigger

    Customer traffic consistently generated packets with a very specific set of attributes and contents, and these packets set off a latent defect in the network device operating system on one layer of the Direct Connect network in Tokyo.

    Root cause
    Component
    Contributing factor
    Detection

    Internal alarms alerted AWS engineers to elevated packet loss for Direct Connect customers connecting to the Tokyo Region at 7:30 AM JST. The automation that monitors network devices also saw a higher rate of failed devices than normal and alerted engineers.

    Remediation
    • Removed the failing network devices from service so healthy devices carried the traffic, which helped only for a time
    • Reset failed devices and brought them back into service slowly, without stopping the failures
    • Disabled the new protocol in a single Availability Zone, then across the Tokyo Region
    Action items
    • Apply the change carefully to all other AWS Regions, with a new way to detect and remediate the issue before customers are affected
  4. Symptoms

    During the Americas' morning of 4 January 2021, an external monitoring service paged Slack because error rates were creeping up. While the investigation was starting, Slack's own dashboarding and alerting service became unavailable, so responders had to work without their usual dashboards and alerts.

    Trigger

    On the first working day after the holidays, Slack's traffic went from the quietest time of the year to one of its biggest days overnight, with cold client caches pulling more data than usual, and one of Slack's AWS Transit Gateways did not scale fast enough for it.

    Root cause
    Component
    Contributing factor
    Detection

    An external monitoring service paged Slack when error rates started creeping up during the Americas' morning. AWS engineers were separately alerted to the packet drops by AWS's internal monitoring.

    Remediation
    • Disabled automated downscaling of the web tier to keep serving capacity and allow investigation
    • Cleared up the broken, partly provisioned instances that filled the autoscaling groups
    • Repaired provision-service so new web tier instances could be provisioned and enter service
    • AWS engineers increased the Transit Gateway capacity manually across all Availability Zones
    Action items
    • AWS reviews its Transit Gateway scaling algorithms for large packet-per-second increases
    • Request a preemptive upscaling of the Transit Gateways at the end of the next holiday season
    • Run the dashboard service instances in the same VPC as their database to remove the Transit Gateway dependency
    • Load test provision-service regularly
    • Reevaluate health-checking and autoscaling configurations so they cannot overload provision-service again
    Lessons

    Monitoring has to stay as independent as possible of the infrastructure it watches, or it fails when it is needed most. Here the dashboard and alerting services failed because they ran in a different VPC from their databases and so depended on the Transit Gateways. provision-service had been load tested before, but this event exceeded the earlier scale-ups.