Cases2 cases
1 to 2 of 2
By root cause1
Capacity exhaustion2 cases
- Contributing factor
- Organisation
IL-0204An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API serverRender2024IL-0075Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the APICivis Analytics2019