  1. Symptoms

    From 22:25 to 22:50 UTC every DigitalOcean service in the SFO3 region had network connectivity problems, as traffic between the datacenter and the backbone dropped. Traffic through the router was back by 22:30 and SFO3's control plane systems had reconnected by 22:50, and most services recovered then.

    Trigger

    Most of the line cards on one SFO3 core router rebooted at the same time at 22:21 UTC because of hardware errors on the device.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • The crashed line cards came back online and traffic on the core router was restored
    • Manually recycled all affected nodes across the SFO3 DOKS fleet
    Action items
    • Work with the router vendor's support team to find the root cause of the line card crash
    • Upgrade software on the core routers in SFO3
    • Raise thresholds for automated remediation so affected nodes are restored without manual action
    Lessons

    A short network fault can leave Kubernetes nodes broken long after the network itself is healthy, when the guest networking on the machines does not recover by itself. Checking node health and the API servers after the network returns, and having automated remediation that is allowed to replace many nodes at once, shortens that tail.

  2. Symptoms

    At 23:48 CET on 24 January 2024 the Scaleway Kubernetes API for the FR-PAR region ran out of memory. At the same minute Scaleway saw requests to its API Gateway spike.

    Trigger

    Simultaneous deployments in the FR-PAR region pushed the Scaleway Kubernetes API out of memory.

    Root cause
    Component
    Contributing factor
    Detection

    Increased load on the API Gateway was detected at 23:48, the minute the incident began, and the incident was escalated to on-call engineers at 00:00:10.

    Remediation
    • raised the memory limit and garbage collection thresholds of the Kubernetes managed services
    • deployed additional replicas of key services
    • purged the registry cache and monitored the clusters as they stabilised
    • adjusted service configurations after the incident to keep the platform stable
    Action items
    • Implement a local authentication cache
    • Further develop node authentication
    • Enhance monitoring, adjust rate limiting strategies and improve incident response protocols
    Lessons

    Because the Kubernetes API also handled node authentication, its memory exhaustion made some nodes NotReady, and the endless retries of those nodes added load on the API Gateway. Scaleway plans a local authentication cache and further work on node authentication.

  3. Symptoms

    Customers of DigitalOcean Managed Kubernetes (DOKS) saw worker nodes go NotReady between 06:00 and 07:00 UTC and stay unavailable, taking down the services on them, until the nodes were replaced or rebooted; some nodes needed several replacements or reboots. The first sporadic reports on October 8 said replacing the node fixed it. The same thing happened again around 06:00 UTC on October 9, more widely and across many regions, and again on October 10. Only clusters on versions 1.27.6-do.0 and 1.28.2-do.0 were affected.

    Trigger

    A systemd timer in the DigitalOcean Debian image started apt upgrade daily at 06:00 UTC, with a random delay of up to 60 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Sporadic customer reports of failed worker nodes arrived at 07:43 UTC on October 8; internal incident response started at 07:10 UTC on October 9 after broader impact across regions.

    Remediation
    • Advised customers to replace or reboot affected worker nodes
    • Arranged SSH and console access to worker nodes while they were healthy, and live-debugged an affected node on October 10
    • Released a DaemonSet to all affected clusters that disables the apt upgrade systemd timer on every worker node
    • Released new node images without the auto-update process
    Action items
    • Disable the timer during node provisioning, then remove the DaemonSet from all clusters
    • Add a check to the internal conformance test suite for new cluster versions that the auto-upgrade process and other unwanted timers stay disabled
    • Support logging into worker nodes even when normal access paths are broken
    Lessons

    An operating system auto-update timer left enabled in a node image can change the kernel and systemd underneath Kubernetes, and a timeout that kills the upgrade half-way can leave a node without networking. Failures that start at the same time every day point to a scheduled job on the nodes, and systemd timers belong on that list next to cron jobs. When the failure takes out a node's network, an investigation that depends on logging into the node stalls; access paths that work while the node is broken shorten diagnosis.

  4. Symptoms

    On 2022-10-31 a planned upgrade of the vpc-cni EKS add-on, started from the deployment pipeline at 13:45 UTC, timed out at 14:10. Only about 10 of the 45 aws-node pods had upgraded, 5 were stuck in Terminating and the other 30 had not been attempted.

    Trigger

    At 07:30 UTC on 2022-10-31 the daily node rollover replaced the existing nodes with nodes built from AMI v20221027, the latest AWS EKS node AMI, released on 2022-10-29 and later recalled because of a kernel issue.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed nodes flapping between NodeNotReady and NodeReady ("KubeletNotReady PLEG is not healthy") at 14:30 UTC while watching the stalled vpc-cni upgrade, about seven hours after the rollover. Time to detection was 7 hours. Alerting did not catch the NodeNotReady events or the socket growth.

    Remediation
    • cordoned, drained and deleted 15 stuck nodes one at a time to complete the vpc-cni upgrade
    • changed the Terraform infrastructure-modules so a specific AMI could be set
    • rolled the EC2 Auto Scaling group launch configuration back to the previous known good AMI through the pipeline
    Action items
    • Reach out to teams with suggestions about readiness and liveness probes
    • Create a dashboard for readiness and liveness probe coverage
    • Write a wiki article on readiness and liveness probes and their usefulness
    • Modify infrastructure-modules to allow specifying a particular AMI
    • Schedule a discussion on whether to take the latest AMI immediately and how to test new AMIs before they are deployed
    • Implement alerting on abnormal NodeNotReady events and on increased socket use
    • Create a learning path for Kubernetes within the team
    • Collect logs from nodes centrally
    • Create a Prometheus exporter that retrieves the latest available AMI, with a dashboard and alerts
    Lessons

    When a new node AMI has just been rolled out, upgrading other cluster components on the same day makes it hard to tell which change is causing trouble; here the vpc-cni upgrade on the same day confused matters. Taking the latest AMI automatically with no way to pin one meant a rollback first needed a Terraform change. The team also concluded that it needs better communication paths with application teams during incidents.

  5. Symptoms

    On 30 May 2019, in the run-up to the Kubernetes 1.15 code freeze, Prow test jobs in the k8s-prow-build cluster failed in surprising ways or were aborted partway through. Jobs were reported to GitHub as failed while Deck still showed them as running, because pods exited without uploading `finished.json`, the file most Prow tooling uses to tell a job's state.

    Trigger

    A spike in test load before the Kubernetes 1.15 code freeze pushed disk I/O on the build nodes far beyond the IOPS that GCP allows for 250 GB disks.

    Root cause
    Component
    Contributing factor
    Detection

    Several users reported jobs that GitHub showed as failed but Deck showed as still running, and the first report came on Slack at 13:26. Alerting for these failures did not exist or did not work.

    Remediation
    • Requested and received additional disk quota
    • Brought up 55 nodes with 500 GB disks in a new node pool
    • Migrated all nodes from the 250 GB disk pool to the 500 GB disk pool by draining old nodes, finishing at 23:55
    Action items
    • Create or fix monitoring so the oncall is paged when tide stops doing things
    • Set a process and guidelines for adding new members to the oncall rotation, with preparation and extra support
    Lessons

    Prow metrics were not recorded before the incident, which made it hard to understand, and alerting for these failures did not exist or did not work. After the cause was found and a fix devised, nothing happened for another two hours. The team counts it as luck that someone who recognised IOPS as the problem happened to be around to look.

Check your cluster for this

These 9 cases involve kubelet and Linux kernel. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled

Capacity exhaustion3 cases

  1. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  2. IL-0401 Prow jobs on the k8s-prow-build GKE cluster failed and merges stalled as nodes hit IOPS throttling and kernel panics
  3. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Configuration change2 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Software defect3 cases

Organisation
  1. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  2. IL-0074 All AirMap platform services down as worker nodes went NotReady and pods crash-looped on network and DNS failures
    AirMap2018
  3. IL-0038 kubelet rollout hit a Kubernetes bug and left every node in a cluster NotReady, triggering mass pod eviction
    Oath2018