Cases2 cases
1 to 2 of 2
IL-0063VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checksAdGuard VPN2025- Symptoms
The day began with an alert that several instances of the Redis cluster were running out of disk space. That part was fixed quickly. The outage came an hour later: right after the Redis StatefulSet was deleted and recreated at 8:10 UTC, Kubernetes restarted every Redis pod within about five minutes, and problems started to appear.
- Trigger
To make Git match the volumes that had been resized by hand, the Redis StatefulSet was deleted with orphan (non-cascading) deletion and recreated with the new storage template; Kubernetes reconciled the new spec by restarting the entire Redis cluster.
- Root cause
- Component
- Contributing factor
- Detection
An alert about Redis instances running out of disk space started the work; the outage itself showed up as backend errors about Redis connections right after the StatefulSet was recreated.
- Remediation
- made the Redis masters forget obsolete node identities, reset the affected replicas and rejoined them, then waited for replication to catch up
- identified the component that was actually running out of memory, scaled the backend service and raised memory limits for that component
- temporarily relaxed probes so backend instances took traffic immediately instead of flapping between ready and not ready
- reverted the temporary workarounds at 10:00 UTC
- Action items
- Add startup probes so a Redis pod is not marked ready until its dataset is loaded
- Build an own control plane for Redis that handles restarted pods stuck to an old master address
- Reduce dependence on the single Redis cluster: move some important data to other stores, such as a separate Redis cluster per server, and use Kafka for some backend components
- Lessons
The disk resize was not the problem; the cleanup afterwards was. An immutable field pushes operators toward deleting and recreating the controller, and that can set off a full reconcile. Startup and readiness probes are what slow a rolling restart down to a safe pace; without them a distributed store restarts in the most fragile way. Recovery plans must expect a cluster to heal slowly, and dependent services need to degrade gracefully while it does.
IL-0027All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went downBackpackr2025- Symptoms
Services on the production Amazon EKS cluster behind the idus marketplace threw intermittent errors whose cause was hard to pin down. Calls to external services such as RDS and Redis failed now and then, and whenever DNS traffic spiked, domain lookups answered slowly or failed outright.
- Trigger
All CoreDNS pods were scheduled onto the same node, and that node's memory usage spiked until it ran out of memory.
- Root cause
- Component
- Contributing factor
- Detection
The write-up does not say how the full outage was noticed. The earlier DNS trouble showed up as intermittent service errors, and investigating failed calls to RDS and Redis led to DNS resolution failures.
- Remediation
- deployed NodeLocal DNSCache as a DaemonSet in front of CoreDNS
- added a PodDisruptionBudget (maxUnavailable 1) and topologySpreadConstraints across zones for CoreDNS
- lowered ndots from 5 to 2 with dnsConfig in the Deployments
- Lessons
The CoreDNS setup that EKS creates by default (two pods) can be enough for a small or development cluster but becomes a bottleneck in a large production cluster, and DNS is a single point of failure that needs high availability and room to scale. Tuning the CoreDNS cache and buffer size only relieved the symptoms; the real load came from the extra queries that ndots:5 generates for external names. A CoreDNS pod without a memory limit can share a node's fate with everything else on it.
These 2 cases involve Container memory limit and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause2
Configuration change1 case
- Contributing factor
- Organisation
Capacity exhaustion1 case
- Contributing factor