Cases2 cases
1 to 2 of 2
IL-0240Cloudflare API requests failed and the dashboard slowed for hours after the authentication database lost its replicasCloudflare2020- Symptoms
On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.
- Trigger
At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.
- Root cause
- Component
- Contributing factor
- Detection
At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.
- Remediation
- Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
- Moved API traffic that could use read replicas to the secondary data center by hand
- Sent authentication calls fully back to the primary data center when the dashboard got worse
- Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
- Ramped the turned-down services back up so asynchronous processing could catch up
- Action items
- Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
- Redesign the user sessions system so dashboard traffic can be steered between data centers
- Change the auto-remediation configuration so a database replica is not promoted so quickly
- Tune each system involved to be more resilient to failures of its dependencies
- Lessons
Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.
IL-0263GitHub was slow and erroring all day and down for 18 minutes as links between access and aggregation switches saturatedGitHub2012- Symptoms
On Friday, 30 November 2012, GitHub had sporadic bursts of slow responses and intermittent errors for the whole day and was completely unavailable for 18 minutes. One fileserver pair was offline for a large part of the day, which affected a small percentage of repositories; this was a side effect of the network problems on the high-availability clustering between the fileserver nodes.
- Trigger
On the morning of 30 November GitHub moved the A switches in its server cabinets onto the new aggregation switches, the second half of a migration whose B-switch half had been done the day before.
- Root cause
- Component
- Contributing factor
- Detection
Engineers saw the problems during the maintenance itself: connectivity to the B switch was lost as the last A switch was connected, and afterwards performance stayed low and the links between access and aggregation switches showed as completely saturated.
- Remediation
- Fixed the bridge-loop problem and returned the affected B switch to service
- Removed the partial link failure detection setting from the access switches
- Escalated to the network vendor, which raised the case to its highest severity level
- Restarted core processes on the aggregation switches in a Saturday 0600 Pacific maintenance window so they learned MAC addresses again
- Action items
- Deploy the vendor's software update that fixes the MAC learning issue to the switches
- Closely monitor aggregation-to-access capacity and keep a workaround process ready if the problem returns
- Build a duplicate of the network stack, from the routers through the access switches, as a staging environment for testing such changes
- Add automated network monitoring that alerts sooner on similar issues
- Run scheduled incident response exercises with scenarios that counter tunnel vision
- Contact the network vendor's support at the first sign of trouble in the network
- Lessons
GitHub had designed the maintenance to have no impact on customers and clearly failed, so it plans to invest in a staging copy of its network to test such changes and catch bugs like this one. During the response the team fixated for a long time on a bridge loop, which kept it from considering other causes. GitHub had a very positive experience with the vendor's support staff, so it will contact that support team at the first sign of network trouble.
These 2 cases involve NIC, cable and switch port link and Coordination and key-value store. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.