Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    Customers of DigitalOcean Managed Kubernetes (DOKS) saw worker nodes go NotReady between 06:00 and 07:00 UTC and stay unavailable, taking down the services on them, until the nodes were replaced or rebooted; some nodes needed several replacements or reboots. The first sporadic reports on October 8 said replacing the node fixed it. The same thing happened again around 06:00 UTC on October 9, more widely and across many regions, and again on October 10. Only clusters on versions 1.27.6-do.0 and 1.28.2-do.0 were affected.

    Trigger

    A systemd timer in the DigitalOcean Debian image started apt upgrade daily at 06:00 UTC, with a random delay of up to 60 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Sporadic customer reports of failed worker nodes arrived at 07:43 UTC on October 8; internal incident response started at 07:10 UTC on October 9 after broader impact across regions.

    Remediation
    • Advised customers to replace or reboot affected worker nodes
    • Arranged SSH and console access to worker nodes while they were healthy, and live-debugged an affected node on October 10
    • Released a DaemonSet to all affected clusters that disables the apt upgrade systemd timer on every worker node
    • Released new node images without the auto-update process
    Action items
    • Disable the timer during node provisioning, then remove the DaemonSet from all clusters
    • Add a check to the internal conformance test suite for new cluster versions that the auto-upgrade process and other unwanted timers stay disabled
    • Support logging into worker nodes even when normal access paths are broken
    Lessons

    An operating system auto-update timer left enabled in a node image can change the kernel and systemd underneath Kubernetes, and a timeout that kills the upgrade half-way can leave a node without networking. Failures that start at the same time every day point to a scheduled job on the nodes, and systemd timers belong on that list next to cron jobs. When the failure takes out a node's network, an investigation that depends on logging into the node stalls; access paths that work while the node is broken shorten diagnosis.

  2. Symptoms

    On 30 August 2022 at 11:15 AM Pacific time, the UToronto JupyterHub at jupyter.utoronto.ca stopped responding and users could not reach it at all. The outage was reported through 2i2c's support desk.

    Trigger

    Microsoft Azure rolled out an Ubuntu update to all Ubuntu 18.04 nodes, which triggered a systemd bug that broke networking.

    Root cause
    Component
    Contributing factor
    Detection

    The outage was reported at 11:15 AM through 2i2c's Freshdesk support desk because jupyter.utoronto.ca was not responding. At 11:25 AM the customer's representative forwarded the Microsoft advisory on the same ticket, which pointed the team to the cause.

    Remediation
    • Started an upgrade of the cluster's Kubernetes and node versions, which replaced all old nodes with new working ones
    Action items
    • Document how to SSH into the Kubernetes nodes
    • Find a way to be notified of Azure advisories
    Lessons

    Once the cause was known, a single action brought the hub back quickly. The team had no documented way to SSH into its Kubernetes nodes, and the customer's representative saw the Azure advisory and pointed it out on the support ticket, which saved a lot of time.

Check your cluster for this

These 2 cases involve Node operating system image and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.