Cases2 cases
1 to 2 of 2
IL-0442Older pods on LIFULL's KEEL Kubernetes cluster were preempted all at once and the external error rate spikedLIFULL2021- Symptoms
Shortly after the KEEL team applied new PriorityClasses to KEEL, LIFULL's Kubernetes cluster, and saw pods with the low class being preempted as intended, the team received a flood of alerts from external monitoring: the error rate of requests coming from outside the cluster had risen sharply.
- Trigger
The KEEL team deployed three PriorityClasses to the running cluster: low with value: 100, medium with globalDefault: true and value: 1000, and high with value: 10000.
- Root cause
- Component
- Contributing factor
- Detection
External monitoring sent the team a large number of alerts about a sharp rise in the error rate of requests from outside the cluster.
- Action items
- Redefine the PriorityClasses as low (-10), medium (0, globalDefault) and high (10), each with a non-preempting variant
- Lessons
Adding PriorityClasses to a running cluster needs care because every existing pod has priority 0, and a globalDefault class above 0 makes all pods created before it candidates for preemption. PodDisruptionBudgets do not reliably protect pods from preemption. In a multi-tenant cluster, the permission to deploy PriorityClasses should be restricted, and the PriorityClasses tenants may use should be controlled with ResourceQuota or OPA Gatekeeper.
IL-0004A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus downGrafana Labs2019- Symptoms
On Friday 19 July 2019 the Grafana Cloud Hosted Prometheus service, which is built on the Cortex project, was down for 26 minutes. New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start.
- Trigger
An engineer created a new dedicated Cortex cluster for a large customer. Its configuration did not include the new pod priorities, so all its pods got the default medium priority, and the Kubernetes cluster did not have enough free resources to fit it.
- Root cause
- Component
- Contributing factor
- Detection
New error-budget-based Prometheus alerts paged the on-call engineer within 4 minutes of the start of the outage.
- Remediation
- Scaled up the underlying Kubernetes cluster to fit both the new and the production Cortex clusters
- Diagnosed and fixed the out-of-memory errors in the authenticating reverse proxies in front of Cortex
- Action items
- Give the production ingesters the high priority class, which should have been done before medium became the default
- Have more people review changes to configuration that is global to the cluster
- Require a design document for every configuration change outside a namespace
- Automate the sizing of the frontend authenticating reverse proxy so it does not run out of memory under overload
- Investigate the default backoff and scaling behaviour of Prometheus to prevent a stampeding herd of retries
- Lessons
Medium should not have become the default priority until the production ingesters had the high priority, and that designation should have reached production sooner. The change was considered too minor for a design document and was only discussed in a GitHub issue; cluster-global configuration needs more scrutiny. On the positive side, once Cortex had enough capacity it recovered by itself, and Grafana Loki helped confirm that the ingesters exited gracefully.
These 2 cases involve Pod priority and preemption and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Configuration change2 cases
- Contributing factor
- Organisation