Incident Library
API · MCP
한국어
All
Capacity exhaustion
51
Software defect
45
Configuration change
35
Faulty deployment
14
Breaking change in an upgrade
14
Dependency failure
13
DNS or network fault
9
Cloud provider outage
8
Operator error
7
Certificate or credential expiry
6
Hardware failure
3
Not stated
3
Credential exposure
1
Root cause
Component
Symptom
Contributing factor
Case
Filters
2
Cases
2 cases
1 to 2 of 2
By root cause
2
Faulty deployment
1 case
Component
Cloud load balancer
Ingress controller
Pod termination
Contributing factor
Unverified assumption
Unreviewed defaults
Monitoring blind spot
Organisation
Yonghyun Kim
IL-0188
Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
Yonghyun Kim
2025
DNS or network fault
1 case
Component
Cloud load balancer
conntrack table
Horizontal pod autoscaler
Ingress controller
kube-proxy
Pod termination
Contributing factor
Unreviewed defaults
Organisation
Lotte E-commerce
IL-0178
On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB
Lotte E-commerce
2022
한국어