  1. Symptoms

    At 11:36 PM PDT on 9 June, alerts fired across multiple OpenAI services as a large number of cloud-hosted GPU nodes lost network connectivity, and the engineering team was escalated to immediately. Losing those nodes cut the capacity available to serve ChatGPT and the API.

    Trigger

    A routine daily scheduled update of the host operating system on the cloud-hosted GPU servers restarted systemd-networkd on the affected nodes.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts fired immediately across multiple services when the infrastructure began losing network connectivity at 11:36 PM PDT, and the engineering team was escalated to at once.

    Remediation
    • re-imaged the affected GPU virtual machines
    • deployed recovery automation to restart the remaining impacted nodes
    • halted the background update mechanisms on the GPU VMs
    Action items
    • Disable automatic daily updates on GPU VMs so updates run in a controlled, scheduled way
    • Update system configurations to prevent conflicts between systemd-networkd and the networking service
    • Audit VM configurations across the fleet to find and reduce similar risks
    • Improve recovery speed for critical infrastructure such as GPU VMs and clusters
    • Run regular disaster recovery drills
    Lessons

    An unattended operating system update that restarts systemd-networkd can wipe the routes another networking agent manages, and it hits every node that takes the update at about the same time. Without break-glass tooling to restore connectivity, nodes that lost their network had to be re-imaged, which stretched recovery over many hours.

  2. Symptoms

    Between 06:00 and 07:00 UTC on 8 March 2023, Kubernetes nodes in several Datadog regions lost network connectivity at the same time, on AWS, Google Cloud and Azure. All services across multiple regions were affected, including the regions that host Datadog's CI/CD and automation tools. Datadog's regions are not connected to each other and changes are rolled out one region at a time, so a simultaneous failure on several cloud providers looked implausible at first.

    Trigger

    On 7 March 2023 Ubuntu published a systemd patch for a CVE (249.11-0ubuntu3.7). Ubuntu's default unattended upgrades installed it on the nodes between 06:00 and 07:00 UTC on 8 March, and installing it restarted systemd-networkd.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted thousands of disconnected instances on Google Cloud and Azure through the cloud APIs, keeping their local disks
    • rebuilt the data lost with terminated AWS instances' local disks through replication, reprocessing and restores from backup
    Lessons

    A change in a base operating system component can stay dormant for months until something restarts that component. Here the trigger was a security patch, and the change reached every region at once because automatic OS updates ran outside the progressive, region-by-region process used for every other change. Cloud providers react differently to an instance that loses its network. Google Cloud and Azure left the instances running, so a restart recovered them with their disks; AWS replaced them quickly, which brought stateless services back fast but destroyed the local-disk data the stateful services needed.