Cases4 cases
1 to 4 of 4
IL-0006VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletionNeon2025- Symptoms
On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.
- Trigger
On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.
- Root cause
- Component
- Contributing factor
- Detection
As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.
- Remediation
- Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
- Fixed the control plane's periodic job so idle computes were terminated again
- Restarted the aws-node DaemonSet several times, each with a temporary improvement
- Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
- On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
- Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
- Action items
- Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
- Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
- Change the architecture to support horizontal scaling
- Lessons
With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.
IL-0007The AWS VPC CNI could not assign IP addresses to pods as an EKS cluster ran out of IPv4 spaceAdevinta2024- Symptoms
One evening the platform team that runs SCHIP, Adevinta's internal runtime platform on Kubernetes, was paged because some DaemonSets were failing. Checking the pod status showed this error from the network plugin: name="aws-cni" failed (add): add cmd: failed to assign an IP address to container
- Trigger
Not stated for the first page. It came in June, during the migration from SCHIP's kube-aws-based clusters to EKS-based clusters; the write-up mentions spikes of pods, such as a job that goes rogue or failing jobs that keep their IPs, as ways a cluster can run out.
- Root cause
- Component
- Contributing factor
- Detection
A pager alert that some DaemonSets were failing. The on-call engineer checked the pod status and found the aws-cni error about failing to assign an IP address.
- Remediation
- Rolled out VPC CNI custom networking with a secondary CIDR to the smaller clusters from late August
- Paused the EKS migration in September while available IPs were very low
- Rolled out custom networking to the rest of the fleet
- Added the --reserved-enis parameter to the Karpenter deployment
- Action items
- Use VPC CNI custom networking with a secondary CIDR across the whole fleet
- Make Karpenter account for custom networking with the --reserved-enis parameter
- Lessons
For a platform team, the VPC CNI is not ready to scale in production without time spent on capacity planning, and every option has its pros and cons. For large clusters started today, IPv6 is the cheaper and more future-proof option. Do not assume that what works in small clusters will keep working when they grow.
IL-0056Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the nodeMindTickle2020- Symptoms
On the Saturday the production cluster was moved from kops to EKS, the platform became very slow and too unstable to keep running, and the team reverted.
- Trigger
Production was moved from a kops cluster using Weave networking to a new EKS cluster using the AWS VPC CNI, without external SNAT enabled.
- Root cause
- Component
- Contributing factor
- Detection
The team lead saw the platform behaving very slowly after the switch to EKS and phoned the author.
- Remediation
- reverted production to the kops cluster
- set AWS_VPC_K8S_CNI_EXTERNALSNAT=true in the AWS VPC CNI
- Action items
- Monitor and alert on the AWS VPC CNI
- Lessons
In a networking problem every component in the stack is a suspect; ruling out EKS early cost a lot of time. A DaemonSet that pinged every component from every other one exposed the anomaly that led to the fix. The team had only skimmed the AWS CNI documentation before the migration; knowing how the plugin works internally would have led to better judgements and hypotheses while debugging.
IL-0057Higher p99 latency after moving a reverse proxy to EKS, from outgoing connections delayed by a SNAT conntrack racePrezi2019- Symptoms
Prometheus alerts fired on tail latency: from 7/24, the p99 response time of a few services went up after Prezi moved its Nginx-based reverse proxy, smartgateway, from dedicated Elastic Beanstalk machines onto shared Kubernetes worker nodes. The bump affected only the tail, so the earlier monitoring of average response times would most certainly have missed it.
- Trigger
Moving the reverse proxy onto shared EKS worker nodes, where its outgoing connections went through source NAT on the node and some SYN packets were dropped by a race in Netfilter's conntrack.
- Root cause
- Component
- Contributing factor
- Detection
Prometheus alerts on p99 latency fired after the reverse proxy migration.
- Remediation
- added AWS X-Ray tracing and an $upstream_connect_time trace attribute to locate the delay
- ran more pods of the service on more nodes, which reduced but did not end the delays
- set AWS_VPC_K8S_CNI_EXTERNALSNAT=true on the AWS VPC CNI to turn off SNAT on the nodes
- Lessons
Alerting on tail latency instead of averages caught a problem that would otherwise have gone unnoticed, and tracing turned a vague slowdown into a measured connect delay. Delays of exactly 1 or 3 seconds on new outgoing connections point to dropped SYN packets, and on EKS the SNAT done by the VPC CNI is where to look.
These 4 cases involve AWS VPC CNI and VPC subnet or pod address range. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause2
Capacity exhaustion2 cases
- Contributing factor
DNS or network fault2 cases
- Contributing factor
- Organisation