  1. Symptoms

    On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.

    Trigger

    At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.

    Root cause
    Component
    Contributing factor
    Detection

    Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.

    Remediation
    • Fixed both VPC route reflectors by manual action
    Action items
    • Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
    • Run different software versions on the route reflectors so a single bug cannot stop several instances
    • Investigate the software issue that left the route reflectors in a stale state
  2. Symptoms

    At 10:01 UTC on 2024-03-13 a Kubernetes node entered NotReady state, with CPU requests at 78% and memory requests at 82%. An alert fired in Slack at 10:03 and was picked up at 10:05. An attempt to SSH into the node at 10:13 failed because it was unresponsive; it started responding again at 10:19.

    Trigger

    Pods of a dev container that used Hangfire to trigger jobs failed with OOM and crash-looped on a node where a Grafana Agent pod was already using a lot of memory.

    Root cause
    Component
    Contributing factor
    Detection

    A Slack alert fired two minutes after the node went NotReady and was picked up two minutes later; the second node's NotReady at 15:03 also raised a Slack alert.

    Remediation
    • marked the EC2 instance unhealthy so a new node started
    • cordoned and force-drained the NotReady node and terminated its EC2 instance
    • removed the new LimitRange from the Grafana Agent namespace and restarted the Grafana Agent pod
    • scaled the dev container to 0 replicas, after which EC2 network traffic returned to normal
    • after the second NotReady, scaled the dev container to 0 replicas again and added a new node
    • emailed the team that owns the dev container, which confirmed it was working on a fix
    Action items
    • Move grafana-agent to the monitoring node group
    • Add alerts for when bandwidth across the cluster reaches a certain threshold
    • Investigate whether memory limits can be set on the grafana-agent Helm chart
    • Investigate grafana-agent memory usage
    • Ask Grafana support whether grafana-agent should use a PVC
    • Consider pushing node logs to Loki with limited retention
    • Create a wiki page with common metrics and log queries to check when investigating issues with Kubernetes nodes
    Lessons

    Dev workloads mixed with production let one crash-looping dev container take down nodes that production also used, and a monitoring agent outside its dedicated node group added to the memory pressure. Scaling the suspect container back up before its owners had fixed it brought the failure back on the replacement node. The team also noted that action items from earlier post-mortems need follow-up, and that knowledge of useful CloudWatch metrics had not been shared, which made the diagnosis harder.

  3. Symptoms

    During a team dinner, a Slack alert reported that one node of the CockroachDB cluster behind Cookie Run: Kingdom had gone down. The DevOps engineers were not worried at first, because CockroachDB is built to survive the loss of some nodes.

    Trigger

    A cooling system failure in an AWS Tokyo region data centre overheated the servers in one availability zone, which held CockroachDB nodes.

    Root cause
    Component
    Contributing factor
    Detection

    A Slack alert reported that a database node had gone down.

    Remediation
    • copied the data outside the broken ranges into new tables with INSERT INTO ... SELECT queries that skipped the affected ranges
    • ran debug unsafe-remove-dead-replicas together with Cockroach Labs engineers, recovering one of the two lost data ranges
    • restored the last data range with the storage-layer recovery method from the previous incident
    Action items
    • Configure CockroachDB Locality so data is spread evenly across availability zones
    • Deploy with one chart and a separate values file per availability zone to set Locality
    • Replace nodes by adding Locality-configured nodes, confirming replicas in every zone, then retiring the old nodes
    Lessons

    A replication factor sized for random instance retirements does not protect against a whole availability zone failing; for a game of this scale a multi-AZ placement is required, not optional. Keeping one uniform Helm chart made zone topology hard to set, which is part of why it was left out. A repetitive chart with a values file per zone sets it reliably.

  4. Symptoms

    The NU.nl development team got reports that several services on one of its Kubernetes clusters behaved erratically: occasional error pages, slow responses and timeouts. The affected services were mostly internal tools and dashboards.

    Trigger

    A new ElastAlert rule, deployed shortly before from the command line, that fired if the Cloudfront-* Elasticsearch indexes stopped receiving documents; those indexes take a few million requests per hour, and the rule made ElastAlert's memory grow without bound.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported error pages, slow responses and timeouts from several services; no alert fired.

    Remediation
    • terminated the NotReady nodes one by one so the auto-scaling group replaced them (the new nodes also went NotReady, but Prometheus and Grafana landed on a stable node)
    • found the ElastAlert pods' memory growth on the Grafana pod memory dashboard
    • fixed the ElastAlert problem that caused the memory growth
    Action items
    • Define alerts on resource usage such as CPU, memory and disk space
    • Keep researching an alerting strategy that combines Elasticsearch, Prometheus Alertmanager and New Relic
    • Consider exporting metrics out of the cluster and running Grafana outside it, on EC2 or a separate Kubernetes cluster
    • Either visualise the important metrics in the ELK stack or make Prometheus and Grafana more available, and improve the metrics strategy
    • Set resource limits for ElastAlert through the Helm values
    • Configure namespaces with default memory requests and limits
    • Isolate customer-facing workloads from build, logging and monitoring workloads (a dedicated node group, or later a separate tools cluster)
    • Deploy everything through automation such as Jenkins pipelines, and consider a GitOps approach
    • Deploy through a pipeline that includes a smoke test step
    • Make Kubernetes and cloud infrastructure work part of the team's sprints, picked up by all team members while pairing with more experienced members, and hold workshops that go deep into specific topics
    Lessons

    Fixing the root cause covers only a small part of what an incident can teach; the chain of smaller failures around it is where most of the learning is. A pod without a memory limit can take whole nodes down, so limits need defaults at the namespace level. Monitoring that runs inside the cluster it watches goes blind with it. Changes installed by hand from the command line leave the rest of the team without a record of what changed.

  5. Symptoms

    An upgrade of the network subsystem under Target's datacenter OpenStack, meant to cause only a brief disruption, ran into problems and left network connectivity disrupted for several hours. Kafka, which runs on that OpenStack, became intermittently available.

    Trigger

    A network subsystem upgrade in the datacenter OpenStack infrastructure disrupted connectivity for several hours and made Kafka intermittently available.

    Root cause
    Component
    Contributing factor
    Remediation
    • enabled gossip encryption on Consul so messages from the poisoned mesh were rejected
    • stabilized the deployment engine and redeployed the development environment with encryption, terminating instances without it
    • upgraded Consul in place to 1.2.3 and then to 1.3.0
    Action items
    • Reduce how much of an outage a single Docker daemon can cause, together with running smaller and more numerous clusters
    Lessons

    Smaller and more numerous clusters limited the damage: the smaller development clusters and production were not hit the same way as the one large cluster, and dev and prod on one cluster would have been far worse. A Docker daemon shared by many workloads is a brittle failure point. Per-workload logging and metrics sidecars were judged the right design; a shared cluster-level agent would almost certainly have made the problem worse and harder to fix.

Check your cluster for this

These 7 cases involve Database and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause5

Software defect2 cases

Organisation
  1. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  2. IL-0038 kubelet rollout hit a Kubernetes bug and left every node in a cluster NotReady, triggering mass pod eviction
    Oath2018

Capacity exhaustion2 cases

Organisation
  1. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  2. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Cloud provider outage1 case

Component
Organisation
  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured

Configuration change1 case

Organisation
  1. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Dependency failure1 case

Organisation
  1. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019